Retrofitting of continuous glucose monitoring traces allows more accurate assessment of glucose control in outpatient studies.

Simone Del Favero1, Andrea Facchinetti, Giovanni Sparacino, Claudio Cobelli.   

Abstract

BACKGROUND: Glucose control in artificial pancreas (AP) studies is commonly assessed by metrics such as the percentage of time with blood glucose (BG) concentration below 70 mg/dL or in the nearly normal range 70-180 mg/dL (in brief, time in hypoglycemia and time in target, respectively). In outpatient studies these control metrics can be computed only from continuous glucose monitoring (CGM) sensor data, with the risk of an unfair assessment because of their inaccuracy. The aim of the present article is to show that the control metrics can be much more accurately determined if CGM data are preprocessed by a recently proposed retrofitting algorithm. SUBJECTS AND METHODS: Data from 47 type 1 diabetes subjects are considered. Subjects were studied in a closed-loop control trial prescribing three 24-h admissions. Glucose concentration was monitored using the Dexcom(®) (San Diego, CA) SEVEN(®) Plus CGM sensor. Frequent BG reference values were collected in parallel with the YSI analyzer (Yellow Springs Instrument, Yellow Springs, OH). To simulate the few reference values available in outpatient conditions, we down-sampled the YSI data and provided to the retrofitting algorithm only the reference values that would have been collected in outpatient protocols. Time in hypoglycemia, time in target, mean, and SD of glucose profile were computed on the basis of both the original and the retrofitted CGM traces and compared with those computed using the frequently obtained YSI data.
RESULTS: Using the retrofitted traces, the average error affecting the estimation of time in hypoglycemia and time in target was approximately halved with respect to the original CGM traces (from 4.5% to 1.9% and from 8.7% to 4.4%, respectively). Error in mean and SD was reduced even further, from 10.0 mg/dL to 3.5 mg/dL and from 8.6 mg/dL to 2.9 mg/dL, respectively.
CONCLUSIONS: The improved accuracy of retrofitted CGM with respect to the original CGM traces allows a more reliable assessment of glucose control in outpatient AP studies.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25671379     DOI: 10.1089/dia.2014.0230

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  7 in total

Review 1.  Mobile technology and the digitization of healthcare.

Authors:  Sanjeev P Bhavnani; Jagat Narula; Partho P Sengupta
Journal:  Eur Heart J       Date:  2016-02-11       Impact factor: 29.983

2.  A Personalized Week-to-Week Updating Algorithm to Improve Continuous Glucose Monitoring Performance.

Authors:  Stamatina Zavitsanou; Joon Bok Lee; Jordan E Pinsker; Mei Mei Church; Francis J Doyle; Eyal Dassau
Journal:  J Diabetes Sci Technol       Date:  2017-10-16

3.  Insulin Sensitivity Index-Based Optimization of Insulin to Carbohydrate Ratio: In Silico Study Shows Efficacious Protection Against Hypoglycemic Events Caused by Suboptimal Therapy.

Authors:  Michele Schiavon; Chiara Dalla Man; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2018-02       Impact factor: 6.118

4.  Intentional Large Insulin Overdose Captured on a Continuous Glucose Monitor: A Novel Case Report.

Authors:  Ahmed H El-Laboudi; Shivani Misra; Marcus Martineau; Paramjeet Deol; Alison Sanders; Nick Oliver
Journal:  J Diabetes Sci Technol       Date:  2015-04-07

Review 5.  Continuous glucose monitoring in the ICU: clinical considerations and consensus.

Authors:  James S Krinsley; J Geoffrey Chase; Jan Gunst; Johan Martensson; Marcus J Schultz; Fabio S Taccone; Jan Wernerman; Julien Bohe; Christophe De Block; Thomas Desaive; Pierre Kalfon; Jean-Charles Preiser
Journal:  Crit Care       Date:  2017-07-31       Impact factor: 9.097

Review 6.  Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.

Authors:  Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino
Journal:  Biosensors (Basel)       Date:  2018-03-13

Review 7.  Outcome Measures for Artificial Pancreas Clinical Trials: A Consensus Report.

Authors:  David M Maahs; Bruce A Buckingham; Jessica R Castle; Ali Cinar; Edward R Damiano; Eyal Dassau; J Hans DeVries; Francis J Doyle; Steven C Griffen; Ahmad Haidar; Lutz Heinemann; Roman Hovorka; Timothy W Jones; Craig Kollman; Boris Kovatchev; Brian L Levy; Revital Nimri; David N O'Neal; Moshe Philip; Eric Renard; Steven J Russell; Stuart A Weinzimer; Howard Zisser; John W Lum
Journal:  Diabetes Care       Date:  2016-07       Impact factor: 19.112

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.