Literature DB >> 25665431

[Comparison of the shaping capability of reciprocating instruments in simulated canals in vitro].

Shao Tongfei, Hou Xiaomei, Hou Benxiang.   

Abstract

OBJECTIVE: This study aims to evaluate the shaping capability of Reciproc, WaveOne, Mtwo, and ProTaper instruments in simulated root canals.
METHODS: A total of 40 simulated resin blocks were divided randomly into four groups. Each group was prepared with Reciproc (Group 1), WaveOne (Group 2), Mtwo (Group 3), and ProTaper (Group 4). The preparation time and reduction in working length after preparation were measured. Pre- and post-operative images were obtained with a scanner and superimposed through Photoshop. The changes in canal curvature and material removal from the inner and outer canal walls at 10 points beginning at 1 mm from the end point of the canal were measured with Image J. Centering capability was determined accordingly. Data were analyzed through one-way ANOVA, SNK, and Kruskal-Wallis at a significance level of P < 0.05.
RESULTS: The preparation time of Group 2 was (53.7 ± 6.7) s, whereas those of Groups 1, 3, and 4 were (86.9 ± 8.1) s, (112.2 ± 8.2) s, and (177.9 ± 11.2) s, respectively; the difference was found to be significant (P < 0.05). The reductions in working length among the four groups after preparation were not significantly different (P > 0.05). The canal curvature for Groups 1 to 4 were 2.671° ± 0.637°, 2.667° ± 0.450°, 3.664° ± 0.870°, and 3.797° ± 0.601°, respectively. The changes for Groups 1 and 2 were significantly smaller than those for Groups 3 and 4. At the 3 mm point, the transportation of Group 1 was (-0.016 ± 0.094) mm, which was significantly less than that of the other instruments (P<0.05). At the 4 mm and 5 mm points, the trans- portation values of Group 2 were (-0.080 ± 0.104) mm and (-0.312 ± 0.088) mm, which were significantly less than that of Group 1 [(-0.243 ± 0.099) mm, (-0.404 ± 0.064) mm, P < 0.05].
CONCLUSION: Reciproc and WaveOne can complete preparation faster and can maintain the original canal curvature better than Mtwo and ProTaper. Reciproc exhibits superior centering capability in the apical part of the canal, whereas WaveOne exhibits superior centering capability in the middle part of the canal.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25665431      PMCID: PMC7030701     

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  17 in total

1.  Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques.

Authors:  C C Ferraz; N V Gomes; B P Gomes; A A Zaia; F B Teixeira; F J Souza-Filho
Journal:  Int Endod J       Date:  2001-07       Impact factor: 5.264

2.  Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement.

Authors:  G De-Deus; E J L Moreira; H P Lopes; C N Elias
Journal:  Int Endod J       Date:  2010-12       Impact factor: 5.264

3.  Phase transformation behaviour and bending property of twisted nickel-titanium endodontic instruments.

Authors:  Xm Hou; Y Yahata; Y Hayashi; A Ebihara; T Hanawa; H Suda
Journal:  Int Endod J       Date:  2011-01-10       Impact factor: 5.264

4.  Canal preparation using only one Ni-Ti rotary instrument: preliminary observations.

Authors:  G Yared
Journal:  Int Endod J       Date:  2007-12-12       Impact factor: 5.264

5.  Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections.

Authors:  Xuejun Xu; M Eng; Yufeng Zheng; D Eng
Journal:  J Endod       Date:  2006-02-07       Impact factor: 4.171

6.  A method for the construction of simulated root canals in clear resin blocks.

Authors:  P M Dummer; M H Alodeh; M A al-Omari
Journal:  Int Endod J       Date:  1991-03       Impact factor: 5.264

7.  Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.

Authors:  Satish B Alapati; William A Brantley; Masahiro Iijima; William A T Clark; Libor Kovarik; Caesar Buie; Jie Liu; William Ben Johnson
Journal:  J Endod       Date:  2009-11       Impact factor: 4.171

8.  Removal of broken files from root canals by using ultrasonic techniques combined with dental microscope: a retrospective analysis of treatment outcome.

Authors:  Mei Fu; Zhiling Zhang; Benxiang Hou
Journal:  J Endod       Date:  2011-05       Impact factor: 4.171

9.  A comparison of canal preparations in straight and curved root canals.

Authors:  S W Schneider
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1971-08

10.  Comparison of the centering ability of Wave·One and Reciproc nickel-titanium instruments in simulated curved canals.

Authors:  Young-Jun Lim; Su-Jung Park; Hyeon-Cheol Kim; Kyung-San Min
Journal:  Restor Dent Endod       Date:  2013-02-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.