Mojahede Salmani Nodoushan1, Amir Houshang Mehrparvar2, Ziba Loukzadeh3, Masoud Rahimian4, Mohamad Ali Ghove Nodoushan5, Reza Jafari Nodoushan6.
Abstract
BACKGROUND: Despite the presence of many textile and dyeing plants in Iran, we couldn't find similar studies in this country. Forthermore, considering progress in the dyeing process and engineering controls, assessment of respiratory system is important for these workers. The present study was performed to evaluate the respiratory system in dyeing workers.Entities:
Keywords: Respiratory symptoms; Spirometry; Textile insustryasthma
Year: 2014 PMID: 25664289 PMCID: PMC4301238
Source DB: PubMed Journal: Med J Islam Repub Iran ISSN: 1016-1430
Demographic and occupational history of dyeing workers and control group
|
| Minimum | Maximum | Mean | SD | p-value | |
| Age (year) | Dyeing | 21 | 48 | 31.4 | 6.1 | |
| Control | 23 | 48 | 32.0 | 6.1 | 0.48 | |
| Height (cm) | Dyeing | 163 | 186 | 174.2 | 5.2 | |
| Control | 161 | 187 | 175.3 | 5.7 | 0.35 | |
| Weight (kg) | Dyeing | 64 | 96 | 78.4 | 9.4 | |
| Control | 66 | 98 | 76.3 | 9.6 | 0.31 | |
| Work experience (year) | Dyeing | 0.8 | 20 | 7.0 | 5.1 | |
| Control | 1 | 20 | 8.2 | 5.2 | 0.10 |
Frequency of acute symptoms in dyeing workers and control groups
|
Eye |
Eye |
Eye | Rhinorrhea |
Nose |
Nasal |
Irritation |
Itching | Headache | |
| Dyeing (n=101) |
28 |
29 |
18 |
17 |
5 |
25 |
18 |
17 |
33 |
|
Control |
7 |
3 |
6 |
6 |
0 |
3 |
3 |
0 |
4 |
| P-value | <0.001 | <0.001 | 0.020 | 0.040 | 0.60 | 0.001 | 0.002 | 0.001 | 0.001 |
Number (%)
Fig. 1
Mean ± SD of pre-shift spirometric parameters in dyeing and control groups.
| Dyeing workers | Controls | P-value | |
| FVC (lit) | 4.13 ± 0.47 | 4.48 ± 0.80 | <0.001 |
| FVC% predicted | 87.90 ± 8.73 | 95.50± 12.04 | <0.001 |
| FEV1(lit) | 3.51 ± 0.41 | 3.76 ± 0.64 | < 0.001 |
| FEV1% predicted | 89.1± 8.60 | 95.5± 12.20 | <0.001 |
| FEV1/FVC (%) | 85.2 ± 6.62 | 83.7± 4.16 | 0.090 |
| FEF25-75% (lit/s) | 4.00 ± 1.10 | 4.10 ± 0.98 | 0.500 |
| FEF25% (lit/s) | 6.91 ± 1.48 | 6.93 ± 1.29 | 0.900 |
| FEF50% (lit/s) | 4.33 ± 1.32 | 4.38 ± 1.12 | 0.700 |
| FEF75% (lit/s) | 1.87 ± 0.59 | 1.85 ± 0.54 | 0.800 |
Across-shift changes in spirometric parameters in dyeing and control groups
| Across-shift changes | P-value | |||
| Mean ± SD | (%) | |||
| FVC (ml) | Dyeing | -120 ± 0.16 | -2.8 | <0.001 |
| Control | -49 ± 0.10 | -1.2 | ||
| FEV1 (ml) | Dyeing | -103 ± 0.15 | -2.8 | <0.001 |
| Control | +18 ± 0.16 | +0.5 | ||
| FEF25-75% | Dyeing | -129 ± 0.44 | -2.9 | 0.050 |
| (lit/s) | Control | -17 ± 0.35 | -0.0 | |
| FEF25% | Dyeing | -144 ± 0.78 | -1.6 | 0.007 |
| (lit/s) | Control | +134 ± 0.57 | +2.3 | |
| FEF50% | Dyeing | -31 ± 0.55 | -0.5 | 0.600 |
| (lit/s) | Control | +1 ± 0.47 | +0.9 | |
| FEF75% | Dyeing | -104 ± 0.26 | -4.7 | 0.080 |
| (lit/s) | Control | -36 ± 0.26 | -1.2 | |