Literature DB >> 25662672

Mid-Term Outcomes and Complications with Cementless Distal Locking Hip Revision Stem with Hydroxyapatite Coating for Proximal Bone Defects and Fractures.

Lluis Carrera1, Sleiman Haddad2, Joan Minguell2, Carles Amat1, Pablo S Corona1.   

Abstract

We revised the first 100 revision total hip arthroplasties using a cementless distal locking revision stem conducted in our referral centre. Average follow-up was 9.2 years (range: 5.5-12 years). Harris Hip Score improved from 42.5 to 81.6, and none had thigh pain at last follow-up. No significant stress shielding, osteolysis, or radiologic loosening was found. All patients showed radiological evidence of secondary implant osseointegration. Overall survival was 97% with three patients being revised: two stem ruptures and one subsidence. We could trace these complications to technical errors. These findings suggest that a diaphyseal fixation of the revision stem with distal locking can provide the needed primary axial and rotational stability of the prosthesis. This would allow further bony ingrowth, enhanced by the hydroxyapatite coating.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  arthroplasty; bone defect; distal locking; hip; hydroxyapatite; revision

Mesh:

Substances:

Year:  2015        PMID: 25662672     DOI: 10.1016/j.arth.2015.01.026

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Long-term survivorship of a monoblock long cementless stem in revision total hip arthroplasty.

Authors:  Yannick Herry; Anthony Viste; Hugo Bothorel; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2018-10-01       Impact factor: 3.075

2.  A Case Report of Implant Fracture of Extensively Porous-Coated, Distally Fixated Cementless Long Stem: Detailed Course of Stem Bending Development.

Authors:  Tomohiro Mimura
Journal:  Case Rep Orthop       Date:  2015-05-21

3.  Levofloxacin loaded mesoporous silica microspheres/nano-hydroxyapatite/polyurethane composite scaffold for the treatment of chronic osteomyelitis with bone defects.

Authors:  Qi Wang; Cheng Chen; Wen Liu; Xiaoqiang He; Nian Zhou; Dongli Zhang; Hongchen Gu; Jidong Li; Jiaxing Jiang; Wei Huang
Journal:  Sci Rep       Date:  2017-02-02       Impact factor: 4.379

4.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

5.  The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora.

Authors:  Yonathan Buks; Kirk L Wendelburg; Susan M Stover; Tanya C Garcia-Nolen
Journal:  Vet Surg       Date:  2016-01-15       Impact factor: 1.495

6.  Fracture risk of tapered modular revision stems: a failure analysis.

Authors:  Kilian Rueckl; Peter K Sculco; Jonathan Berliner; Michael B Cross; Chelsea Koch; Friedrich Boettner
Journal:  Arthroplast Today       Date:  2017-12-21

7.  Fracture of an S-ROM stem at the sleeve-stem junction.

Authors:  Kilian Rueckl; Friedrich Boettner; Ulrich Bechler; Elexis C Baral; Timothy M Wright; Peter K Sculco
Journal:  Arthroplast Today       Date:  2018-05-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.