Literature DB >> 25658077

Biomechanical comparison of hamstring tendon fixation devices for anterior cruciate ligament reconstruction: Part 2. Four tibial devices.

Brian P Scannell1, Bryan J Loeffler, Michael Hoenig, Richard D Peindl, Donald F D'Alessandro, Patrick M Connor, James E Fleischli.   

Abstract

We conducted a study to biomechanically compare 4 tibial hamstring tendon fixation devices commonly used in anterior cruciate ligament reconstruction. Quadrupled human semitendinosus-gracilis tendon grafts were fixed into porcine tibias using 4 separate fixation devices. For each device, 10 specimens were tested (1500-cycle loading test at 50-200 N). Specimens surviving the cyclic loading then underwent a single load-to-failure test. Failure mode, stiffness, ultimate load, and residual displacement were recorded. Eight of 10 Delta screw (Arthrex), 2 of 10 Retroscrew (Arthrex), 10 of 10 WasherLoc (Arthrotek), and 10 of 10 Intrafix (Depuy Mitek) devices completed the 1500-cycle loading test. Residual displacement was significantly (P < .001) lower for Intrafix (2.9 mm), WasherLoc (5.6 mm), and Delta (6.4 mm) than for Retroscrew (25.5 mm). Mean stiffness was significantly (P < .05) higher for Intrafix (129 N/mm) than for the other devices. Mean load to failure was highest for Intrafix (656 N), then WasherLoc (630 N), Delta (430 N), and Retroscrew (285 N). The Intrafix device demonstrated superior strength in the fixation of hamstring grafts in the tibia. WasherLoc was close behind.

Entities:  

Mesh:

Year:  2015        PMID: 25658077

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  6 in total

1.  Graft fixation influences revision risk after ACL reconstruction with hamstring tendon autografts.

Authors:  Andreas Persson; Tone Gifstad; Martin Lind; Lars Engebretsen; Knut Fjeldsgaard; Jon Olav Drogset; Magnus Forssblad; Birgitte Espehaug; Asle B Kjellsen; Jonas M Fevang
Journal:  Acta Orthop       Date:  2017-11-24       Impact factor: 3.717

2.  Fixation of the Anterior Ligament Graft at the Tibial Pole: Biomechanical Analysis of Three Methods.

Authors:  Fernando Pessoa Weiss; Felipe Augusto de Aguiar Possoli; Isabel Ziesemer Costa; Paulo César Borges; Edmar Stieven Filho; Luiz Fernando Kubrusly
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-12-13

3.  In Vitro Testing of 2 Adjustable-Loop Cortical Suspensory Fixation Systems Versus Interference Screw for Anterior Cruciate Ligament Reconstruction.

Authors:  Gerardo L Garcés; Oscar Martel; Alejandro Yánez; Ignacio Manchado-Herrera; Luci M Motta
Journal:  Orthop J Sports Med       Date:  2021-09-28

4.  Biomechanical cyclic loading test of a synthetic ligament fixation system used for intra-articular stabilization of deficient canine stifles.

Authors:  Bastien Goin; Philippe Buttin; Yoann Lafon; Michel Massenzio; Eric Viguier; Thibaut Cachon
Journal:  Open Vet J       Date:  2022-05-29

5.  Practice Guidelines for the Management of Multiligamentous Injuries of the Knee.

Authors:  Ankit Goyal; Milind Tanwar; Deepak Joshi; Deepak Chaudhary
Journal:  Indian J Orthop       Date:  2017 Sep-Oct       Impact factor: 1.251

6.  Biomechanical analysis of a double fixation method for tendon graft in porcine tibia - using an interference screw plus staple.

Authors:  Luis Antônio de Ridder Bauer; Hermes Augusto Agottani Alberti; Vitor Gustavo de Paiva Corotti; Ana Paula Gebert de Oliveira Franco; Edmar Stieven Filho; Luiz Antônio Munhoz da Cunha
Journal:  Rev Bras Ortop       Date:  2018-07-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.