Literature DB >> 25657198

Prolonged duration of transbrachial intra-aortic balloon pump as bridge to heart transplantation.

Triston B B J Smith1, Puneeth Shridhar1, Ramzi Khalil1, David Michael Lasorda1.   

Abstract

We describe a case demonstrating the quality of life (QOL) benefit and safety of using a transbrachial approach for insertion of an intra-aortic balloon pump (IABP) in a patient awaiting cardiac transplantation. A 68-year-old man with ischaemic cardiomyopathy was admitted to our cardiac intensive care unit to await the availability of a suitable donor organ for orthotopic heart transplant. An IABP was needed for haemodynamic support due to cardiogenic shock. Since the patient did not want to be committed to lying supine in bed for multiple days, as would have been the case had the IABP been placed using the conventional femoral route, we inserted a 7.5 Fr 'sheathless' IABP via the transbrachial approach. The patient's haemodynamics improved and the device was left in place for 240 h without vascular compromise. He was subsequently successfully transplanted and is doing well on follow-up. 2015 BMJ Publishing Group Ltd.

Entities:  

Mesh:

Year:  2015        PMID: 25657198      PMCID: PMC4330429          DOI: 10.1136/bcr-2014-208658

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  13 in total

1.  Transbrachial intra-aortic balloon pumping for high-risk percutaneous coronary intervention.

Authors:  Konstantinos Aznaouridis; Andro G Kacharava; Michelle Consolini; A Maziar Zafari; Kreton Mavromatis
Journal:  Am J Med Sci       Date:  2011-02       Impact factor: 2.378

2.  Extended duration of brachially inserted intra-aortic balloon pump for myocardial protection in two patients undergoing urgent coronary artery bypass grafting.

Authors:  Shantu Bundhoo; Peter A O'Keefe; Heyman Luckraz; Nick Ossei-Gerning
Journal:  Interact Cardiovasc Thorac Surg       Date:  2007-11-28

3.  Transbrachial insertion of an intra-aortic balloon pump for high-risk percutaneous coronary intervention.

Authors:  Trevor Simard; Benjamin Hibbert; Brendan Parfrey; Edward R O'Brien
Journal:  Clin Res Cardiol       Date:  2012-05-03       Impact factor: 5.460

4.  Feasibility of 6 Fr intra-aortic balloon pumping via the femoral or brachial approach.

Authors:  Toshiharu Fujii; Naoki Masuda; Takeshi Ijichi; Yoshinari Kamiyama; Shigemitsu Tanaka; Gaku Nakazawa; Norihiko Shinozaki; Takashi Matsukage; Nobuhiko Ogata; Yuji Ikari
Journal:  J Invasive Cardiol       Date:  2012-12       Impact factor: 2.022

5.  Transbrachial intra-aortic balloon pumping for a patient with fulminant myocarditis.

Authors:  Iwao Okai; Kenji Inoue; Masaki Maruyama; Sonomi Maruyama; Kaoru Komatsu; Hirohito Nishizawa; Shinya Okazaki; Yasumasa Fujiwara; Masataka Sumiyoshi; Hiroyuki Daida
Journal:  Heart Vessels       Date:  2012-02-17       Impact factor: 2.037

6.  Supported percutaneous coronary intervention using a novel 6-Fr intra-aortic balloon pump catheter via the brachial artery in a nonagenarian patient with an abdominal aortic aneurysm.

Authors:  Akihiko Takahashi; Norimasa Taniguchi
Journal:  Catheter Cardiovasc Interv       Date:  2011-03-16       Impact factor: 2.692

7.  Use of novel 6 French intra-aortic balloon pump catheter for patients undergoing percutaneous coronary intervention.

Authors:  Takeshi Yamada; Yukio Mizuguchi; Shingo Sakamoto; Norimasa Taniguchi; Shunsuke Nakajima; Akihiko Takahashi
Journal:  ASAIO J       Date:  2013 Sep-Oct       Impact factor: 2.872

8.  Safety and efficacy of transbrachial intra-aortic balloon pumping with the use of 7-Fr catheters in patients undergoing coronary bypass surgery.

Authors:  Antonino S Rubino; Francesco Onorati; Filiberto Serraino; Attilio Renzulli
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-04-21

Review 9.  Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials.

Authors:  Jin M Cheng; Corstiaan A den Uil; Sanne E Hoeks; Martin van der Ent; Lucia S D Jewbali; Ron T van Domburg; Patrick W Serruys
Journal:  Eur Heart J       Date:  2009-07-18       Impact factor: 29.983

10.  Percutaneous placement of an intra-aortic balloon pump in the left axillary/subclavian position provides safe, ambulatory long-term support as bridge to heart transplantation.

Authors:  Jerry D Estep; Andrea M Cordero-Reyes; Arvind Bhimaraj; Barry Trachtenberg; Nashwa Khalil; Matthias Loebe; Brian Bruckner; Carlos M Orrego; Jean Bismuth; Neal S Kleiman; Guillermo Torre-Amione
Journal:  JACC Heart Fail       Date:  2013-09-11       Impact factor: 12.035

View more
  1 in total

1.  Myocardial protective effects of a c-Jun N-terminal kinase inhibitor in rats with brain death.

Authors:  Wenzhi Guo; Shengli Cao; Bing Yan; Gong Zhang; Jie Li; Yongfu Zhao; Shuijun Zhang
Journal:  J Cell Mol Med       Date:  2016-04-12       Impact factor: 5.310

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.