Literature DB >> 25652477

Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy.

W Assmann1, S Kellnberger2, S Reinhardt1, S Lehrack1, A Edlich1, P G Thirolf1, M Moser3, G Dollinger3, M Omar2, V Ntziachristos2, K Parodi1.   

Abstract

PURPOSE: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam.
METHODS: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE.
RESULTS: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10(12) eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations.
CONCLUSIONS: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25652477     DOI: 10.1118/1.4905047

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Theoretical detection threshold of the proton-acoustic range verification technique.

Authors:  Moiz Ahmad; Liangzhong Xiang; Siavash Yousefi; Lei Xing
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Acoustic-based proton range verification in heterogeneous tissue: simulation studies.

Authors:  Kevin C Jones; Wei Nie; James C H Chu; Julius V Turian; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

3.  Proton range verification in homogeneous materials through acoustic measurements.

Authors:  Wei Nie; Kevin C Jones; Scott Petro; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-17       Impact factor: 3.609

Review 4.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

Review 5.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 6.  Online daily adaptive proton therapy.

Authors:  Francesca Albertini; Michael Matter; Lena Nenoff; Ye Zhang; Antony Lomax
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

7.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

8.  Mid-range probing-towards range-guided particle therapy.

Authors:  Mingli Chen; Yuncheng Zhong; Yiping Shao; Steve Jiang; Weiguo Lu
Journal:  Phys Med Biol       Date:  2018-06-27       Impact factor: 3.609

Review 9.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

10.  High Resolution X-ray-Induced Acoustic Tomography.

Authors:  Liangzhong Xiang; Shanshan Tang; Moiz Ahmad; Lei Xing
Journal:  Sci Rep       Date:  2016-05-18       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.