Literature DB >> 25644065

Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study using 3D cone beam computed tomography.

Joo-Young Ohe1, Gyu-Tae Kim2, Jung-Woo Lee1, Bilal Al Nawas3, Junho Jung3, Yong-Dae Kwon1.   

Abstract

OBJECTIVES: The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. PATIENTS AND METHODS: Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)-lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pre-operatively (To), post-op 1 week (T1), 1 month (T2), 3 months (T3), and 6 months (T4). 3D image processing software (OnDemand3DTM software) was used for this study. The time sequential change was statistically evaluated. RESULT: 84.32% grafted BCP is maintained until post-op 6 month (T4), and the average volume loss is 207.7 mm(3) (about 0.21 cc). Statistically, a significant volume change (decreasing) was observed in three groups (T2-T1, T3-T2, T4-T3).
CONCLUSION: Biphasic calcium phosphate, as a synthetic material, has high volume stability and is a predictable graft material for the successful SFE. Although some limitations of the 3D analyzing software program, it is a fast, simple, relatively accurate and promising approach to quantifying long-term changes in the grafted area.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  3D computed tomography; sinus floor elevation; volumetric stability

Mesh:

Substances:

Year:  2015        PMID: 25644065     DOI: 10.1111/clr.12551

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

1.  Accuracy of cone beam computed tomography in following simulated autogenous graft resorption in maxillary sinus augmentation procedure: an ex vivo study.

Authors:  Sanja Umanjec-Korac; Azin Parsa; Aria Darvishan Nikoozad; Daniel Wismeijer; Bassam Hassan
Journal:  Dentomaxillofac Radiol       Date:  2016-05-26       Impact factor: 2.419

2.  Evaluation of volume changes following lateral window maxillary sinus floor elevation using Minics software.

Authors:  Hanfei Zhang; Huiting Hu; Cong Li; Yingxin Ye; Mingdeng Rong; Yong Yang
Journal:  Ann Transl Med       Date:  2022-09

3.  Maxillary sinus augmentation using biphasic calcium phosphate: dimensional stability results after 3-6 years.

Authors:  Jae-Kook Cha; Chingu Kim; Hyung-Chul Pae; Jung-Seok Lee; Ui-Won Jung; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2019-02-26       Impact factor: 2.614

Review 4.  Innovative Concepts and Recent Breakthrough for Engineered Graft and Constructs for Bone Regeneration: A Literature Systematic Review.

Authors:  Francesco Inchingolo; Denisa Hazballa; Alessio Danilo Inchingolo; Giuseppina Malcangi; Grazia Marinelli; Antonio Mancini; Maria Elena Maggiore; Ioana Roxana Bordea; Antonio Scarano; Marco Farronato; Gianluca Martino Tartaglia; Felice Lorusso; Angelo Michele Inchingolo; Gianna Dipalma
Journal:  Materials (Basel)       Date:  2022-01-31       Impact factor: 3.623

5.  A Randomized Controlled Trial of Guided Bone Regeneration for Peri-Implant Dehiscence Defects with Two Anorganic Bovine Bone Materials Covered by Titanium Meshes.

Authors:  JaeHyung Lim; Sang Ho Jun; Marco Tallarico; Jun-Beom Park; Dae-Ho Park; Kyung-Gyun Hwang; Chang-Joo Park
Journal:  Materials (Basel)       Date:  2022-08-01       Impact factor: 3.748

6.  Histologic, Histomorphometric, and Clinical Analysis of the Effects of Growth Factors in a Fibrin Network Used in Maxillary Sinus Augmentation.

Authors:  Ihsan Caglar Cinar; Bahattin Alper Gultekin; Alper Saglanmak; Serdar Yalcin; Vakur Olgac; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2020-03-15       Impact factor: 3.390

7.  Bone regeneration of a polymeric sponge technique-Alloplastic bone substitute materials compared with a commercial synthetic bone material (MBCP+TM technology): A histomorphometric study in porcine skull.

Authors:  Punyada Intapibool; Naruporn Monmaturapoj; Katanchalee Nampuksa; Kriangkrai Thongkorn; Pathawee Khongkhunthian
Journal:  Clin Exp Dent Res       Date:  2021-01-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.