Literature DB >> 25637178

Effect of pupil size on biometry measurements using the IOLMaster.

Galia Adler1, Jonathan Shahar2, Rivka Kesner3, Eldar Rosenfeld2, Naomi Fischer2, Anat Loewenstein2, Shimon Kurtz2.   

Abstract

PURPOSE: To evaluate the effect of pupil dilation on biometric measurements and intraocular lens power calculation using the IOLMaster (Carl Zeiss Meditec).
DESIGN: Prospective, observational case series.
METHODS: In this prospective study, 2 consecutive optical biometry measurements, before and after pupil dilation, were obtained using the IOLMaster on 318 eyes of 214 patients at the cataract presurgery clinic. The parameters compared were axial length, corneal power, cylinder, and the corresponding intraocular lens power, which was calculated using the Sanders-Retzlaff-Kraff/Theoretical formula.
RESULTS: This study found no statistically significant difference before and after dilation in axial length (0.005 mm; P = .476), corneal power (0.001 diopters [D]; P = .933), or calculated intraocular lens power (0.011 D; P = .609). A statistically significant difference was shown in cylinder measurements before and after dilation (0.102 D; P < .001).
CONCLUSIONS: This study demonstrated there is no clinically significant effect of pupil dilation on the IOLMaster measurements of axial length, corneal power, and corresponding theoretical intraocular lens power calculated using the Sanders-Retzlaff-Kraff/Theoretical formula.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25637178     DOI: 10.1016/j.ajo.2015.01.025

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  5 in total

1.  Effect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry.

Authors:  Bharkbhum Khambhiphant; Suganlaya Sasiwilasagorn; Nattida Chatbunchachai; Krit Pongpirul
Journal:  Clin Ophthalmol       Date:  2016-07-27

2.  Influence of pupil dilation on the Barrett universal II (new generation), Haigis (4th generation), and SRK/T (3rd generation) intraocular lens calculation formulas: a retrospective study.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  BMC Ophthalmol       Date:  2020-07-20       Impact factor: 2.209

3.  Influence of pupil dilation on predicted postoperative refraction and recommended IOL to obtain target postoperative refraction calculated by using third- and fourth-generation calculation formulas.

Authors:  Takeshi Teshigawara; Akira Meguro; Nobuhisa Mizuki
Journal:  Clin Ophthalmol       Date:  2018-10-02

4.  The effect evaluation of advanced penlight.

Authors:  Piao-Yi Chiou; Chih-Yin Chien; Yi-Horng Lai; Chang Feng Chun
Journal:  PLoS One       Date:  2018-11-07       Impact factor: 3.240

5.  The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study.

Authors:  Hamed Momeni-Moghaddam; Nasim Maddah; James S Wolffsohn; Mohammad Etezad-Razavi; Siamak Zarei-Ghanavati; Amir Akhavan Rezayat; Majid Moshirfar
Journal:  Ophthalmol Ther       Date:  2019-05-03