Literature DB >> 25627887

Influence of cortical thickness on the stability of mini-implants with microthreads.

Giselle Naback Lemes Vilani1, Antônio Carlos de Oliveira Ruellas1, Cláudia Trindade Mattos1, Daniel Jogaib Fernandes2, Carlos Nelson Elias2.   

Abstract

The objective of this study was to assess the influence of cortical thickness and bone density on the insertion torque of a mini-implant (MI) with microthreads. Mini-implants with lengths of 6 and 8 mm in the active part were inserted into synthetic bone blocks (polyurethane resin). The density of these blocks was 20 pounds per cubic foot (pcf), simulating bone marrow, and that of blocks 1, 2, and 3-mm-thick blocks was 40 pcf, simulating cortical bone. Blocks with uniform density of 40 pcf were also used to simulate bone areas of greater density. Insertion torque was quantified with a universal testing machine (EMIC). For both MIs, increasing insertion torque was associated with increasing cortical bone thickness. For the same MI length, significant differences were observed among all assessed groups. The insertion torque of the 6-mm-long MI inserted in a 3-mm-thick cortical bone was equivalent to that of the 8-mm-long MI inserted in a 1-mm-thick cortical bone. MIs inserted in bone blocks of greater density presented insertion torque values almost twice as high as those in other groups. The shorter MI, the lower the insertion torque, and the greater the cortical bone thickness, the greater the insertion torque. To minimize fracture risk, the size of MI should be selected according to the insertion site.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25627887     DOI: 10.1590/1807-3107BOR-2015.vol29.0023

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

2.  Bacteremia after Orthodontic Miniscrew Insertion.

Authors:  Masood Feizbakhsh; Pedram Daneshkazemi; Sina Mobasherizade; Niloofar Fallah
Journal:  Front Dent       Date:  2022-02-02

3.  Mechanical and histological evaluation of a titanium device for orthodontic anchorage, placed with or without cyanoacrylate adhesive.

Authors:  Anderson Antonio Mamede; Elizabeth Ferreira Martinez; Roberta Tarkany Basting
Journal:  Dental Press J Orthod       Date:  2019-08-01

4.  Evaluation of Optimal Sites for the Insertion of Orthodontic Mini Implants at Mandibular Symphysis Region through Cone-Beam Computed Tomography.

Authors:  Shizhen Zhang; Xiaoyu Wei; Lufei Wang; Zhouqiang Wu; Lu Liu; Xinyu Yan; Wenli Lai; Hu Long
Journal:  Diagnostics (Basel)       Date:  2022-01-23

Review 5.  A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science.

Authors:  Saeid Nosouhian; Mansour Rismanchian; Roya Sabzian; Elham Shadmehr; Hamid Badrian; Amin Davoudi
Journal:  J Int Oral Health       Date:  2015
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.