Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section.

B L Sng1,2, H Wang2, P N Assam2,3, A T Sia1,4.   

Abstract

Hypotension occurs commonly during spinal anaesthesia for caesarean section, associated with maternal and fetal adverse effects. We developed a double-vasopressor automated system with a two-step algorithm and continuous non-invasive haemodynamic monitoring using the Nexfin device. The system delivered 25 μg phenylephrine every 30 s when systolic blood pressure was between 90% and 100% of baseline, or 2 mg ephedrine at this blood pressure range and heart rate < 60 beats.min(-1) ; and 50 μg phenylephrine or 4 mg ephedrine when systolic blood pressure was < 90% of baseline with the same heart rate criterion. Fifty-seven women received standardised spinal anaesthesia. Twenty-seven (47.4%) had at least one reading of hypotension defined as systolic blood pressure < 80% baseline. Systolic blood pressure was within 20% of the baseline in a mean (SD) of 79.8 (20.9)% of measurements. Fifty-three (93.0%) women required phenylephrine before delivery while 10 (17.5%) required ephedrine. Six women (10.5%) experienced nausea and three (5.3%) vomited. The system was able to achieve a low incidence of maternal hypotension with good maternal and fetal outcomes.
© 2015 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25627651     DOI: 10.1111/anae.13008

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2018-09-28       Impact factor: 2.078

2.  Blood pressure measurement during cesarean delivery: Evaluation of a beat-to-beat noninvasive device (NexfinTM).

Authors:  Mathieu Bobet; Jona Joachim; Etienne Gayat; Agnès Bonnet; Kerstin Sievert; Carole Barnichon; Marc Fischler; Morgan Le Guen
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

3.  Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock.

Authors:  Kazunori Uemura; Toru Kawada; Can Zheng; Meihua Li; Masaru Sugimachi
Journal:  BMC Anesthesiol       Date:  2017-10-23       Impact factor: 2.217

Review 4.  Continuous Non-Invasive Arterial Pressure Assessment during Surgery to Improve Outcome.

Authors:  Alena Stenglova; Jan Benes
Journal:  Front Med (Lausanne)       Date:  2017-11-17

5.  Anesthetic management for cesarean section in a patient receiving transplacental treatment of fetal tachyarrhythmia: a case report.

Authors:  Nobuhiro Tanaka; Tomoaki Fujii; Niina Mikami; Yuka Uchinami; Hitoshi Saito; Yuji Morimoto
Journal:  JA Clin Rep       Date:  2019-05-07

6.  Implications of Continuous Noninvasive Finger Cuff Arterial Pressure Device Use during Cesarean Delivery for Goal-Directed Fluid Therapy Preload Optimization: A Randomized Controlled Trial.

Authors:  Shan-Han Yang; Yi-Shiuan Lin; Chien-Nan Lee; Ya-Jung Cheng; Ying-Hsi Chen; Hsin-Chan Chiu; Chun-Yu Wu
Journal:  Biomed Res Int       Date:  2021-03-28       Impact factor: 3.411

7.  Development of an automated closed-loop β-blocker delivery system to stably reduce myocardial oxygen consumption without inducing circulatory collapse in a canine heart failure model: a proof of concept study.

Authors:  Takuya Nishikawa; Kazunori Uemura; Yohsuke Hayama; Toru Kawada; Keita Saku; Masaru Sugimachi
Journal:  J Clin Monit Comput       Date:  2021-05-10       Impact factor: 1.977

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.