Literature DB >> 25625362

Changes in intraocular pressure after descemet stripping automated endothelial keratoplasty: a retrospective analysis.

Luzia Müller1, Claude Kaufmann, Lucas M Bachmann, Janine N Tarantino-Scherrer, Michael A Thiel, Frank Bochmann.   

Abstract

PURPOSE: To analyze the occurrence of postoperative intraocular pressure (IOP) elevation and types of pressure-lowering treatment in patients after Descemet stripping automated endothelial keratoplasty (DSAEK) with and without previous diagnoses of glaucoma and/or pseudoexfoliation (PXF) syndrome.
METHODS: This retrospective assessment considered 211 consecutive DSAEK cases (176 patients) performed by 1 surgeon between January 2007 and November 2010 with at least 1-year follow-up. Salient patient characteristics, IOP, and type of antiglaucoma treatment registered in postoperative visits up to 36 months were extracted from medical records. IOP elevation and its association with glaucoma, PXF, and combination of the 2 were assessed using multivariate ordinal logit models.
RESULTS: Of 211 eyes, 97 eyes (45%) showed at least 1 increase in IOP >25 mm Hg after DSAEK. Of these 97 eyes, 17 eyes (17.5%) had a history of glaucoma alone, another 17 eyes (17.5%) had a history of glaucoma combined with PXF, 10 eyes (9.7%) had PXF alone, and 53 eyes (54.6%) were steroid responders only. To control IOP elevation, steroid reduction alone was performed in 6 eyes (6.2%) and IOP-lowering medication as the only measure was performed in 26 eyes (26.8%). In 46 eyes (47.4%), steroids were reduced in combination with IOP-lowering medication and 16 eyes (16.5%) required surgery. In 3 eyes (3.1%), no action was required. Presence of PXF (odds ratio, 1.71; 95% confidence interval, 0.62-2.81; P = 0.002) and PXF glaucoma (1.14; 95% confidence interval, 0.06-2.21; P = 0.038) required a more intensive IOP-lowering management than patients without PXF with IOP problems.
CONCLUSIONS: Increased IOP is common after DSAEK, and a significant number of patients need IOP-lowering treatment. PXF syndrome and PXF glaucoma are risk factors for significant IOP elevation after DSAEK. In most cases, IOP remains controlled with conservative management, but some patients require glaucoma surgery.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25625362     DOI: 10.1097/ICO.0000000000000342

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  7 in total

Review 1.  [Complications of Descemet Stripping Automated Endothelial Keratoplasty (DSAEK)].

Authors:  M A Thiel; F Bochmann; A Schmittinger-Zirm; P B Bänninger; M K Schmid; C Kaufmann
Journal:  Ophthalmologe       Date:  2015-12       Impact factor: 1.059

2.  Microbial keratitis in corneal grafts: predisposing factors and outcomes.

Authors:  A C O Okonkwo; W F Siah; H D J Hogg; H Anwar; F C Figueiredo
Journal:  Eye (Lond)       Date:  2018-01-26       Impact factor: 3.775

3.  Factors Influencing Graft Endothelial Cell Density after Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Mohammad Ali Javadi; Sepehr Feizi; Roya Jafari; Seyed Bagher Hosseini; Sharareh Safapour
Journal:  J Ophthalmic Vis Res       Date:  2018 Jan-Mar

4.  Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Sepehr Feizi; Mohammad Ali Javadi
Journal:  J Ophthalmic Vis Res       Date:  2019 Jan-Mar

Review 5.  Challenges in the complex management of post-keratoplasty glaucoma.

Authors:  Lisa-Marie Anders; Zisis Gatzioufas; Matthias C Grieshaber
Journal:  Ther Adv Ophthalmol       Date:  2021-07-20

6.  Elevated Cytokine Levels in Aqueous Humor Are Associated with Peripheral Anterior Synechiae after Penetrating Keratoplasty.

Authors:  Yuki Kusano; Takefumi Yamaguchi; Sota Nishisako; Takehiro Matsumura; Masaki Fukui; Kazunari Higa; Toshihiro Inoue; Jun Shimazaki
Journal:  Int J Mol Sci       Date:  2021-11-12       Impact factor: 5.923

7.  Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty.

Authors:  Oded Ohana; David Varssano; Gabi Shemesh
Journal:  Indian J Ophthalmol       Date:  2017-07       Impact factor: 1.848

  7 in total