Literature DB >> 25623263

Central corneal thickness measurements and ultrasonographic study of the growing equine eye.

Lena E Herbig1, J Corinna Eule1.   

Abstract

OBJECTIVE: The aim of this study was to determine the central corneal thickness (CCT) of healthy equine eyes with high-frequency ultrasound (HF) and ultrasound biomicroscopy (UBM) and to measure the axial dimensions with B-mode ultrasound. Additionally, the influence of the age on the measured dimensions of the globe was analyzed. ANIMALS STUDIED: Fifty warm blood horses (mean age 23.0 ± 21.12 months) were divided into 3 age groups (group 1: 0-6 months; group 2: ≥7-30 months; and group 3: ≥31-78 months). PROCEDURE: Corneal measurements were performed with a 22-MHz and a 50-MHz transducer. Crystalline lens thickness (CLT), vitreous chamber depth (VCD), and axial globe length (AGL) were measured at a frequency of 10 MHz. Anterior chamber depth (ACD) was calculated. The eyes were measured under general anesthesia nonrelated to this study.
RESULTS: The mean CCT of 50 eyes was 818 ± 41 μm. The mean values ± SD in mm for axial dimensions were AGL 34.7 ± 2.7, ACD 3.4 ± 0.7, CLT 10.0 ± 0.9, and VCD of 20.4 ± 1.5. A positive correlation with increasing age was found for all dimensions. No significant differences were found between the gender and the left or right eye.
CONCLUSION: HF and UBM are valuable high-resolution imaging tools for CCT measurements in horses. The here-obtained values support previous findings that a positive correlation with increasing age exists for CCT, ACD, CLT, VCD, and AGL in horse.
© 2015 American College of Veterinary Ophthalmologists.

Entities:  

Keywords:  axial dimensions; biometry; corneal development; eye; high-frequency ultrasound; horse

Mesh:

Year:  2015        PMID: 25623263     DOI: 10.1111/vop.12252

Source DB:  PubMed          Journal:  Vet Ophthalmol        ISSN: 1463-5216            Impact factor:   1.644


  3 in total

1.  Ultrasound biomicroscopy of the equine iridocorneal angle.

Authors:  Kelly E Knickelbein; Mary E Lassaline; Soohyun Kim; Sara M Thomasy
Journal:  Equine Vet J       Date:  2022-06-15       Impact factor: 2.692

2.  Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy.

Authors:  Kelly E Knickelbein; Mary E Lassaline; Soohyun Kim; Machal S Scharbrough; Sara M Thomasy
Journal:  Vet Ophthalmol       Date:  2022-01-27       Impact factor: 1.444

3.  Clinical, ultrasonographic, and histopathologic findings in seven horses with Descemet's membrane detachment: A case series.

Authors:  Inge J M Slenter; Hanneke Hermans; Jos M Ensink; Dorien S Willems; Stefanie Veraa; Guy C M Grinwis; Michael H Boevé
Journal:  Vet Ophthalmol       Date:  2019-09-22       Impact factor: 1.644

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.