Literature DB >> 25623254

Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip.

Daisuke Inoue1, Tamon Kabata, Toru Maeda, Yoshitomo Kajino, Kenji Fujita, Kazuhiro Hasegawa, Takashi Yamamoto, Hiroyuki Tsuchiya.   

Abstract

INTRODUCTION: Preoperative planning with computed tomography (CT)-based three-dimensional templating has been expanded to achieve more precise placement of hip components. However, few reports have addressed the utility of three-dimensional surgical planning software for secondary osteoarthritis cases. This study therefore investigated the value of CT-based three-dimensional templating software for preoperative planning in primary total hip arthroplasty (THA), with an emphasis on developmental dysplasia of the hip.
MATERIALS AND METHODS: We performed a retrospective review of 65 hips in 57 patients who underwent cementless primary THA. The preoperative diagnosis was secondary osteoarthritis in all cases due to developmental dysplasia of the hip. All preoperative planning and postoperative evaluations were completed using CT-based three-dimensional templating software. We analyzed the accuracy of stem size prediction and cup size prediction, the reproducibility of preoperative and postoperative stem anteversion, and the absolute error in preoperative and postoperative stem anteversion using CT-based three-dimensional templating software.
RESULTS: The sizes of 65 % of the femoral stems (42/65) were estimated exactly, and 98 % (63/65) were accurately estimated to within one stem size. The final acetabular cup sizes corresponded exactly to the preoperatively planned size in 92 % of all cases (62/65). 100 % of the cup size estimates were accurate to within one cup size. There was strong reproducibility of preoperative and postoperative stem anteversion (r = 0.88, P < 0.05). The absolute error in stem anteversion was 4.0° ± 3.6°.
CONCLUSIONS: Using CT-based three-dimensional templating software made it possible to achieve reproducible stem anteversion and choose accurate stem and cup sizes in patients with developmental dysplasia of the hip.

Entities:  

Mesh:

Year:  2015        PMID: 25623254     DOI: 10.1007/s00776-014-0683-3

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  18 in total

1.  Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Kenji Fujita; Kazuhiro Hasegawa; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-05

2.  The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-06-22

3.  Factors related to disagreement in implant size between preoperative CT-based planning and the actual implants used intraoperatively for total hip arthroplasty.

Authors:  Takeshi Ogawa; Masaki Takao; Takashi Sakai; Nobuhiko Sugano
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-12-13       Impact factor: 2.924

4.  The influence of surgical approach on postoperative pelvic tilt after total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Yoshitomo Kajino; Tadashi Taga; Kazuhiro Hasegawa; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-21

5.  Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.

Authors:  Kazuhiro Hasegawa; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Hiroyuki Tsuchiya
Journal:  Clin Orthop Relat Res       Date:  2016-10-31       Impact factor: 4.176

6.  Conventional computed tomography software can be used for accurate pre-operative templating in bipolar hip arthroplasty: A preliminary report.

Authors:  Nobuaki Chinzei; Mitsuaki Noda; Hiroshi Nashiki; Takehiko Matsushita; Atsuyuki Inui; Shinya Hayashi
Journal:  J Clin Orthop Trauma       Date:  2020-09-06

7.  Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis.

Authors:  Daisuke Inoue; Tamon Kabata; Yoshitomo Kajino; Tadashi Taga; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Case Rep Orthop       Date:  2018-01-31

8.  Digitalized analyses of intraoperative acetabular component position using image-matching technique in total hip arthroplasty.

Authors:  Shinya Kawahara; Toshihiko Hara; Taishi Sato; Kazuki Kitade; Takeshi Shimoto; Tetsuro Nakamura; Taro Mawatari; Hidehiko Higaki; Yasuharu Nakashima
Journal:  Bone Joint Res       Date:  2020-07-23       Impact factor: 5.853

9.  Clinical evaluation of ultrasound screening in follow-up visits of infants with cerebral palsy at high risk for developmental dysplasia of the hip.

Authors:  Aizhen Qiu; Zhongxiu Yang; Jiping Wang; Taotao Wang
Journal:  Exp Ther Med       Date:  2016-09-02       Impact factor: 2.447

10.  Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography-based templating in primary total hip arthroplasty.

Authors:  Feroz A Osmani; Savyasachi Thakkar; Austin Ramme; Ameer Elbuluk; Paul Wojack; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2017-05-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.