Literature DB >> 25622180

Quantitative assessment of responses of the eyeball based on data from the Corvis tonometer.

Robert Koprowski1, Sławomir Wilczyński2, Anna Nowinska3, Anita Lyssek-Boron3, Sławomir Teper3, Edward Wylegala3, Zygmunt Wróbel4.   

Abstract

BACKGROUND: The "air-puff" tonometers, include the Corvis, are a type of device for measuring intraocular pressure and biomechanics parameters. The paper attempts to analyse this response and its relationship with other parameters measured in the Corvis tonometer.
METHODS: A number of 13,400 2D images were acquired from the Corvis device and analysed (32 healthy and 16 ill people). A new method has been proposed for the analysis of responses of the eyeball based on morphological transformations and contextual operations.
RESULTS: The proposed algorithm enables to determine responses of the eyeball to an air puff coming from the Corvis tonometer. Additionally, responses of the eyeball have been linked to some selected features of corneal deformation. The results include, among others: (1) distinguishability between the left and right eye with an error of 7%; (2) the correlation between the area under the curve in corneal deformation and the response of the eyeball -0.26; (3) the correlation between the highest concavity time and the maximum deformation amplitude of 0.4. All these features are obtained fully automatically and repetitively at a time of 3.8s per patient (Core i7 10GB RAM). DISCUSSION: It is possible to measure additional parameters of the eye deformation which are not available in the original software of the Corvis tonometer. The use of the proposed methods of image analysis and processing provides results directly from the eye response measurement when measuring intraocular pressure.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Air-puff; Biomechanics; Corvis; Eye; Image processing; Measurement automation; Tonometer

Mesh:

Year:  2015        PMID: 25622180     DOI: 10.1016/j.compbiomed.2015.01.006

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  5 in total

1.  A new method for detecting the outer corneal contour in images from an ultra-fast Scheimpflug camera.

Authors:  Magdalena Jędzierowska; Robert Koprowski; Sławomir Wilczyński; Katarzyna Krysik
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

2.  Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-11-19       Impact factor: 2.819

3.  Open source software for the analysis of corneal deformation parameters on the images from the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2015-04-11       Impact factor: 2.819

4.  A clinical utility assessment of the automatic measurement method of the quality of Meibomian glands.

Authors:  Robert Koprowski; Lei Tian; Paweł Olczyk
Journal:  Biomed Eng Online       Date:  2017-06-24       Impact factor: 2.819

Review 5.  Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method.

Authors:  Robert Koprowski; Sławomir Wilczyński
Journal:  J Healthc Eng       Date:  2018-02-11       Impact factor: 2.682