Literature DB >> 25621311

In Vitro Ultrasound Measurements of Powered and Unpowered Total Cavopulmonary Connection.

Bp Iliff1, Aem Kerlo2, J Chen3, Md Rodefeld, Cj Goergen.   

Abstract

Three-staged Fontan palliation is performed on children suffering from single ventricle congenital heart disease. The series of surgical procedures reroutes blood from the vena cavae directly to the pulmonary arteries, creating a total cavopulmonary connection (TCPC). A viscous impeller pump (VIP) is currently being developed as a cavopulmonary assist device that can modestly augment cavopulmonary flow, reduce systemic venous pressure, and improve ventricular preload. This study used ultrasound to visualize complex flow patterns in powered and unpowered in vitro mock Fontan circulations. The idealized TCPC was modeled with a silicone mold and blood analog made of water and glycerol that was seeded with 10-μm glass beads. B-mode, color Doppler, and pulsed-wave Doppler images were used to visualize complex flow patterns in the idealized TCPC with (1) no VIP, (2) static VIP, and powered VIP rotation rates of (3) 500 and (4) 2,000 rotations per minute (RPM). Pulsed-wave Doppler data showed higher mean velocities and greater variance in the outlets relative to the larger inlets. The maximum inlet velocity ± SD increased from 10.9 ± 3.53 cm/s with no VIP to 15.9 ± 1.03 when the VIP was rotating at 2,000 RPM. Likewise, the maximum outlet velocity increased from 14.9 ± 11.2 cm/s to 18.9 ± 7.25 cm/s at 2,000 RPM. The faster mean velocities with the VIP rotating suggest that the pump augments cavopulmonary flow. The results of this study suggest that measuring complex flow patterns with ultrasound in vivo could be used clinically to optimize VIP positioning and rotation rate during and after implantation.

Entities:  

Keywords:  Doppler; Fontan; Hemodynamics; Total cavopulmonary connection; Ultrasound

Year:  2014        PMID: 25621311      PMCID: PMC4304092     

Source DB:  PubMed          Journal:  Austin J Biomed Eng


  17 in total

1.  Cavopulmonary assist: circulatory support for the univentricular Fontan circulation.

Authors:  Mark D Rodefeld; Jack H Boyd; Cynthia D Myers; Brian J LaLone; Alex J Bezruczko; Andrew W Potter; John W Brown
Journal:  Ann Thorac Surg       Date:  2003-12       Impact factor: 4.330

Review 2.  The Fontan circulation: What have we learned? What to expect?

Authors:  M R de Leval
Journal:  Pediatr Cardiol       Date:  1998 Jul-Aug       Impact factor: 1.655

3.  Perinatal outcome after prenatal diagnosis of single-ventricle cardiac defects.

Authors:  R S Beroukhim; K Gauvreau; O J Benavidez; C W Baird; T LaFranchi; W Tworetzky
Journal:  Ultrasound Obstet Gynecol       Date:  2015-04-23       Impact factor: 7.299

4.  NIH Image to ImageJ: 25 years of image analysis.

Authors:  Caroline A Schneider; Wayne S Rasband; Kevin W Eliceiri
Journal:  Nat Methods       Date:  2012-07       Impact factor: 28.547

5.  Doppler velocimetry in superior vena cava provides useful information on the right circulatory function in patients with congestive heart failure.

Authors:  S Ghio; F Recusani; R Sebastiani; C Klersy; C Raineri; C Campana; L Lanzarini; A Gavazzi; L Tavazzi
Journal:  Echocardiography       Date:  2001-08       Impact factor: 1.724

6.  Determination of pulmonary capillary wedge pressure using pulsed wave Doppler echocardiography: clinical application of range ambiguity phenomenon.

Authors:  Ho-Ming Su; Tsung-Hsien Lin; Wen-Chol Voon; Wen-Ter Lai; Sheng-Hsiung Sheu
Journal:  J Am Soc Echocardiogr       Date:  2005-10       Impact factor: 5.251

7.  Total cavopulmonary connection: a logical alternative to atriopulmonary connection for complex Fontan operations. Experimental studies and early clinical experience.

Authors:  M R de Leval; P Kilner; M Gewillig; C Bull
Journal:  J Thorac Cardiovasc Surg       Date:  1988-11       Impact factor: 5.209

8.  Pulmonary artery blood flow patterns in fetuses with pulmonary outflow tract obstruction.

Authors:  S Peyvandi; J Rychik; M McCann; D Soffer; Z Tian; A Szwast
Journal:  Ultrasound Obstet Gynecol       Date:  2014-03       Impact factor: 7.299

9.  Comparison of pulsed wave and color Doppler myocardial velocity imaging in healthy dogs.

Authors:  G Wess; M Killich; K Hartmann
Journal:  J Vet Intern Med       Date:  2010 Mar-Apr       Impact factor: 3.333

10.  Cardiac transplantation after the Fontan or Glenn procedure.

Authors:  K Anitha Jayakumar; Linda J Addonizio; Maryanne R Kichuk-Chrisant; Mark E Galantowicz; Jacqueline M Lamour; Jan M Quaegebeur; Daphne T Hsu
Journal:  J Am Coll Cardiol       Date:  2004-11-16       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.