Literature DB >> 25614929

Performance of fluorescence-based methods for detecting and quantifying smooth-surface caries lesions in primary teeth: an in vitro study.

Tatiane Fernandes Novaes1,2, Caroline Moraes Moriyama1, Monique Saveriano De Benedetto3, Eduardo Kazuo Kohara1, Mariana Minatel Braga1, Fausto Medeiros Mendes1.   

Abstract

BACKGROUND: Although smooth-surface caries can be subjectively assessed by visual inspection, quantitative methods would improve the monitoring of these lesions. AIM: To evaluate the in vitro performance of laser fluorescence devices, namely DIAGNOdent (LF) and DIAGNOdent pen (LFpen), and a fluorescence camera (VistaProof; FC) in the detection and quantification of smooth-surface caries in primary teeth.
DESIGN: Two examiners evaluated 99 smooth surfaces of 65 extracted primary molars using FC, LF, and LFpen. As a reference standard, the actual and relative lesion depths were determined using stereomicroscopy and polarized light microscopy. Reproducibilities were assessed, and correlation analyses were performed. The sensitivities, specificities, and accuracies of the methods were calculated and compared.
RESULTS: There was a significant correlation between the values obtained using the fluorescence-based devices and the actual and relative lesion depths, although the correlation coefficient values were not higher than 0.7 (LF, 0.673; LFpen, 0.646; FC, 0.663). The sensitivities of the devices were similar for the detection of enamel caries, although LFpen was superior in detecting dentin lesions. The reliabilities of all methods were moderate to low, with similar accuracies at all depths.
CONCLUSION: Although the fluorescence-based devices showed similar performance in the detection of enamel and dentin lesions, the reliability of these devices and the correlation of their findings with the actual and relative lesion depths were moderate with regard to smooth-surface caries in primary molars.
© 2015 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2015        PMID: 25614929     DOI: 10.1111/ipd.12152

Source DB:  PubMed          Journal:  Int J Paediatr Dent        ISSN: 0960-7439            Impact factor:   3.455


  4 in total

1.  Validation of fluorescence devices for evaluation of white spot lesions in orthodontic patients.

Authors:  K Kavvadia; K Seremidi; C Reppa; M Makou; P Lagouvardos
Journal:  Eur Arch Paediatr Dent       Date:  2018-03-13

2.  Diagnostic Validity in Occlusal Caries Detection of ICDAS II, DIAGNOdent, Radiography and a Combination of the Three Methods: An In Vitro Study.

Authors:  Elena Minuesa-García; José Enrique Iranzo-Cortés; Teresa Almerich-Torres; Carlos Bellot-Arcís; José María Montiel-Company; José Manuel Almerich-Silla
Journal:  J Clin Med       Date:  2022-05-23       Impact factor: 4.964

3.  Fluorescence devices for the detection of dental caries.

Authors:  Richard Macey; Tanya Walsh; Philip Riley; Anne-Marie Glenny; Helen V Worthington; Patrick A Fee; Janet E Clarkson; David Ricketts
Journal:  Cochrane Database Syst Rev       Date:  2020-12-08

4.  Use of DIAGNOdent and VistaProof in diagnostic of Pre-Cavitated Caries Lesions-A Systematic Review and Meta-Analysis.

Authors:  José Enrique Iranzo-Cortés; José María Montiel-Company; Teresa Almerich-Torres; Carlos Bellot-Arcís; José Manuel Almerich-Silla
Journal:  J Clin Med       Date:  2019-12-19       Impact factor: 4.241

  4 in total