Literature DB >> 25613944

Location of achromatizing pupil position and first Purkinje reflection in a normal population.

Silvestre Manzanera1, Pedro M Prieto1, Antonio Benito1, Juan Tabernero1, Pablo Artal1.   

Abstract

PURPOSE: Quality of vision in patients who have undergone corneal refractive surgery depends upon the optimal centration of the procedures used. The center of the pupil is used as a reference point in some corneal ablation procedures. The achromatic axis would be a more sensible option from an optical point of view, but it is not as readily detectable. As an alternative, other refractive techniques, like the small aperture corneal inlay for presbyopia correction, use the corneal reflex (first Purkinje image). To assess the relative position of these two marks, we developed a new instrument to simultaneously measure both the first Purkinje image (PI) and the intersection of the achromatic axis with the pupil plane.
METHODS: The apparatus records images of the pupil and the PI when illuminated with a circle of infrared light-emitting diodes. A second optical path allows determination of the achromatic axis by using a subjective method. Both the positions of the PI and the achromatic axis intersection are determined simultaneously.
RESULTS: A series of data were obtained in 48 eyes. The mean location of the achromatic point relative to the PI was [x = -0.05 ± 0.15 mm; y = 0.09 ± 0.18 mm]. Considered individually, in 55% of eyes, the distance between locations is less than 0.2 mm, and in 95% of eyes, distances are less than 0.4 mm.
CONCLUSIONS: On average, achromatic axis crossing of the pupil and PI locations coincides within measurement errors. Although there was some intersubject variability, differences in location were less than 0.6 mm in all measured eyes. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

Entities:  

Keywords:  Purkinje images; achromatic axis; centration; corneal inlay; presbyopia; small aperture

Mesh:

Year:  2015        PMID: 25613944     DOI: 10.1167/iovs.14-16108

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  2 in total

1.  Anatomical and Visual Outcomes after LASIK Performed in Myopic Eyes with the WaveLight® Refractive Suite (Alcon® Laboratories Inc., USA).

Authors:  Imene Salah-Mabed; Sarah Moran; Emmanuelle Perez; Guillaume Debellemanière; Damien Gatinel
Journal:  J Ophthalmol       Date:  2020-10-03       Impact factor: 1.909

Review 2.  Clinical outcomes of corneal refractive surgery comparing centration on the corneal vertex with the pupil center: a meta-analysis.

Authors:  Jiamei Zhang; Yan Wang; Xiaoqin Chen; Wenjing Wu
Journal:  Int Ophthalmol       Date:  2020-07-15       Impact factor: 2.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.