Literature DB >> 25610107

A new method for hepatic resection and hemostasis: absorbable plaque and suture.

M Tahir Ozer1, Mehmet Eryilmaz2, Kagan Coskun1, Sezai Demirbas1, A Ihsan Uzar1, Orhan Kozak1.   

Abstract

OBJECTIVE: Blunt and penetrating hepatic injuries are conditions that are frequently encountered in emergency surgeries, and they involve high mortality morbidity. In the handling of such injuries, methods ranging from the application of simple cauterization and suturing for hemostasis to hepatic lobectomies, which might involve the removal of the greater part of the organ, have been defined. Due to the organ's fragility and susceptibility to bleeding, elective hepatic resections necessitate both surgical experience and technological equipment. Therefore, the demand still exists for an affordable and easy-to-use-method that could be applied by all centers.
MATERIALS AND METHODS: To meet this demand, we have developed a method of hemorrhage control via sutures supported by absorbable plaques that provide effective compression and prevent the suture from cutting the tissue during the application of the sutures in the treatment of such fragile organs as the liver. In our method, we have achieved hemostasis by bilaterally compressing the tissue through strong ties after placing, on the part of the tissue on which the sutures are applied, absorbable and flexible plaques that prevent the suture from cutting the tissue during the application of a polyglactin suture to the solid organ. To prevent dislocation of the plaques, we have fastened the sutures by reeving them through the holes made in the plaques.
RESULTS: We have demonstrated the success and the practicality of our method by applying it on four pigs; we experimentally inflicted hepatic injuries on two pigs, and we performed resection on the other two pigs. The hepatic hemorrhages we developed in both of the animals were successfully restrained by the use of our method. On the other hand, two resections were performed on the right and left lobes of the other two animals. There were no hemorrhages during the surgery, and the procedure took 45 minutes in total. No postoperative complications occurred. While the liver function test values were high on the seventh day, due to the operation, they were observed to be normal on the thirtieth day. After the laparotomies, performed six months later, we observed that the plaques as well as the sutures were absorbed and that the injured tissues were completely healed. Additionally, it was observed during the pathological examination that the tissues beneath the area of application were healed through fibrosis and that the liver had no other pathologies.
CONCLUSIONS: In conclusion, we believe that the method can be safely used in hepatic resections or traumatic hemorrhages in the proper locations.

Entities:  

Keywords:  Hepatic resection; Hepatic trauma; Plaque and suture

Year:  2010        PMID: 25610107      PMCID: PMC4261311          DOI: 10.5152/eajm.2010.01

Source DB:  PubMed          Journal:  Eurasian J Med        ISSN: 1308-8734


  7 in total

1.  Simplified hepatic resections with the use of a Chang's needle.

Authors:  Yu-Chung Chang; Naofumi Nagasue; Chu-San Chen; Xi-Zhang Lin
Journal:  Ann Surg       Date:  2006-02       Impact factor: 12.969

2.  Ultrasonically activated device for parenchymal division during open hepatectomy.

Authors:  G Belli; P Limongelli; A Belli; C Fantini; A D'Agostino; L Cioffi; G Russo
Journal:  HPB (Oxford)       Date:  2008       Impact factor: 3.647

3.  Transection of the liver with a water jet.

Authors:  B G Persson; B Jeppsson; K G Tranberg; K Roslund; S Bengmark
Journal:  Surg Gynecol Obstet       Date:  1989-03

4.  Microwave surgery: hepatectomy using a microwave tissue coagulator.

Authors:  K Tabuse; M Katsumi; Y Kobayashi; H Noguchi; H Egawa; O Aoyama; H Kim; Y Nagai; H Yamaue; K Mori
Journal:  World J Surg       Date:  1985-02       Impact factor: 3.352

5.  Analysis of the components of hypertransaminasemia after liver resection.

Authors:  Ivo Giovannini; Carlo Chiarla; Felice Giuliante; Maria Vellone; Francesco Ardito; Gerardo Sarno; Gennaro Nuzzo
Journal:  Clin Chem Lab Med       Date:  2007       Impact factor: 3.694

6.  The experimental development of an ultrasonically activated scalpel for laparoscopic use.

Authors:  J F Amaral
Journal:  Surg Laparosc Endosc       Date:  1994-04

7.  Preliminary experience in liver surgery using the ultrasonic scalpel.

Authors:  W J Hodgson; L R DelGuercio
Journal:  Surgery       Date:  1984-02       Impact factor: 3.982

  7 in total
  2 in total

1.  Polyglutamic Acid-Based Elastic and Tough Adhesive Patch Promotes Tissue Regeneration through In Situ Macrophage Modulation.

Authors:  Qiuwen Zhu; Yi Hong; Yuxuan Huang; Yi Zhang; Chang Xie; Renjie Liang; Chenglin Li; Tao Zhang; Hongwei Wu; Jinchun Ye; Xianzhu Zhang; Shufang Zhang; Xiaohui Zou; Hongwei Ouyang
Journal:  Adv Sci (Weinh)       Date:  2022-04-09       Impact factor: 17.521

Review 2.  Recent advances in biopolymer-based hemostatic materials.

Authors:  Marvin Mecwan; Jinghang Li; Natashya Falcone; Menekse Ermis; Emily Torres; Ramon Morales; Alireza Hassani; Reihaneh Haghniaz; Kalpana Mandal; Saurabh Sharma; Surjendu Maity; Fatemeh Zehtabi; Behnam Zamanian; Rondinelli Herculano; Mohsen Akbari; Johnson V John; Ali Khademhosseini
Journal:  Regen Biomater       Date:  2022-09-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.