Literature DB >> 25606546

Early assessment of patient perception of outcome in total knee replacement.

Filippo Boniforti1, Antonio Macaione1, Stefano Gagliardi1, Francesco Giangrasso1, Davide DI Marzo1, Francesco Giacco1.   

Abstract

PURPOSE: the aim of the present study was to measure patient perception in the early period after knee replacement surgery and to correlate health status with the surgery-related outcome.
METHODS: thirty-eight consecutive patients who underwent total knee replacement were evaluated before surgery; at the time Radiographic evaluation was used to assess limb alignment and the Oxford Knee Score (OKS) to assess objective outcome. Health outcome was measured with the three-level version of the EuroQol - five dimension (EQ-5D-3L) self-administered questionnaire, a standardized instrument used to measure patient's perception of health status. Evaluation was performed before surgery, at discharge from hospital, and six weeks after surgery.
RESULTS: the mean overall EQ-5D-3L scores were 10.23 before surgery, 8.34 at discharge from the hospital, and 6.52 at six weeks. The overall EQ-5D-3L score before surgery was greater than 8 points in 31 of the 38 patients, ranging from 5 to 8 points in 21 of the 38 patients at the discharge and greater than 8 points in six of the 38 patients six weeks after surgery. Patients with scores of over 8 points at six weeks also scored more than 10 points on the discharge assessment.
CONCLUSIONS: analysis of early patient reports of performance after TKR showed marked changes in the level of satisfaction during the first six weeks after surgery. An EQ-5D-3L score of 8 or more at follow-up should be considered a sign that the patient has not achieved satisfaction and, accordingly, should be studied in the context of a personalized follow-up schedule in order to identify as soon as possible the causes of impairment. LEVEL OF EVIDENCE: Level IV, prognostic case series.

Entities:  

Keywords:  arthroplasty; knee; perception; questionnaire; replacement

Year:  2014        PMID: 25606546      PMCID: PMC4295672          DOI: 10.11138/jts/2014.2.2.071

Source DB:  PubMed          Journal:  Joints        ISSN: 2512-9090


  13 in total

1.  The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales.

Authors:  P N Baker; J H van der Meulen; J Lewsey; P J Gregg
Journal:  J Bone Joint Surg Br       Date:  2007-07

2.  The routine use of patient reported outcome measures in healthcare settings.

Authors:  Jill Dawson; Helen Doll; Ray Fitzpatrick; Crispin Jenkinson; Andrew J Carr
Journal:  BMJ       Date:  2010-01-18

3.  Timing of total joint replacement affects clinical outcomes among patients with osteoarthritis of the hip or knee.

Authors:  Paul R Fortin; John R Penrod; Ann E Clarke; Yvan St-Pierre; Lawrence Joseph; Patrick Bélisle; Matthew H Liang; Diane Ferland; Charlotte B Phillips; Nizar Mahomed; Michael Tanzer; Clement Sledge; Anne H Fossel; Jeffrey N Katz
Journal:  Arthritis Rheum       Date:  2002-12

4.  The minimal clinically important difference in the Oxford knee score and Short Form 12 score after total knee arthroplasty.

Authors:  N D Clement; D MacDonald; A H R W Simpson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-20       Impact factor: 4.342

5.  Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients.

Authors:  C E H Scott; C R Howie; D MacDonald; L C Biant
Journal:  J Bone Joint Surg Br       Date:  2010-09

6.  Predictors of patient relevant outcome after total hip replacement for osteoarthritis: a prospective study.

Authors:  A-K Nilsdotter; I F Petersson; E M Roos; L S Lohmander
Journal:  Ann Rheum Dis       Date:  2003-10       Impact factor: 19.103

7.  Effects of socioeconomic status on patients' outcome after total knee arthroplasty.

Authors:  Edward T Davis; Elizabeth A Lingard; Emil H Schemitsch; James P Waddell
Journal:  Int J Qual Health Care       Date:  2008-01-03       Impact factor: 2.038

8.  Is patient reporting of physical function accurate following total knee replacement?

Authors:  D F Hamilton; P Gaston; A H R W Simpson
Journal:  J Bone Joint Surg Br       Date:  2012-11

9.  Interpretation of patient-reported outcomes for hip and knee replacement surgery: identification of thresholds associated with satisfaction with surgery.

Authors:  A Judge; N K Arden; A Kiran; A Price; M K Javaid; D Beard; D Murray; R E Field
Journal:  J Bone Joint Surg Br       Date:  2012-03

10.  Patient acceptable symptom states after totalhip or knee replacement at mid-term follow-up: Thresholds of the Oxford hip and knee scores.

Authors:  J C Keurentjes; F R Van Tol; M Fiocco; C So-Osman; R Onstenk; A W M M Koopman-Van Gemert; R G Pöll; R G H H Nelissen
Journal:  Bone Joint Res       Date:  2014-01-13       Impact factor: 5.853

View more
  4 in total

1.  Effects of perceptions of care, medical advice, and hospital quality on patient satisfaction after primary total knee replacement: A cross-sectional study.

Authors:  Tom Schaal; Tonio Schoenfelder; Joerg Klewer; Joachim Kugler
Journal:  PLoS One       Date:  2017-06-13       Impact factor: 3.240

2.  Evaluation of the internal fixation effect of nano-calcium-deficient hydroxyapatite/poly-amino acid composite screws for intraarticular fractures in rabbits.

Authors:  Zhenyu Dai; Yue Li; Yonggang Yan; Ruijie Wan; Qiang Ran; Weizhong Lu; Bo Qiao; Hong Li
Journal:  Int J Nanomedicine       Date:  2018-10-18

3.  The Use of a High-Tech Knee Pad for Reduction of the Postoperative Effusion after Total Knee Arthroplasty.

Authors:  Massimo Innocenti; Michele Mancini; Marina Faccio; Christian Carulli; Paolo Buselli; Sara Messina; Giuseppe Quattrone; Piergiorgio Spaggiari
Journal:  Joints       Date:  2017-06-05

4.  Psychosocial Determinants of Total Knee Arthroplasty Outcomes Two Years After Surgery.

Authors:  Maria A Lopez-Olivo; Aparna Ingleshwar; Glenn C Landon; Sherwin J Siff; Andrea Barbo; Heather Y Lin; Maria E Suarez-Almazor
Journal:  ACR Open Rheumatol       Date:  2020-09-24
  4 in total