Literature DB >> 25606494

Preoperative identification of a perforator using computed tomography angiography and metal clip marking in perforator flap reconstruction.

Jung Woo Lee1, Han Kyeol Kim1, Sin Rak Kim1, Yea Sik Han1, Jin Hyung Park1.   

Abstract

In perforator flap reconstruction, vascular mapping using preoperative computed tomography (CT) angiography is widely used to confirm the existence and location of an appropriate perforator. This study proposes a rapid, accurate, and convenient method for marking the perforator location on the skin surface. For 12 patients who underwent perforator flap reconstruction between November 2011 and November 2013, metal clips were fixed on the skin surface at the anticipated perforator locations, which were decided using a handheld Doppler. CT angiography was used to compare the location between the metal clip and the actual perforator. The metal clip was moved and repositioned, if needed, on the basis of the CT images. The locations of the appropriate perforator and the metal clip, which were observed during the surgery, were then compared. In CT angiography, the mean distance between the metal clip and the perforator was 3±3.9 mm, and the mean distance that was measured during surgery was 0.8±0.8 mm. In conclusion, we report a simple, rapid, and precise technique to indicate the accurate location of the appropriate perforator on the skin surface.

Entities:  

Keywords:  Multidetector computed tomography; Perforator flap; Ultrasonography, Doppler

Year:  2015        PMID: 25606494      PMCID: PMC4297811          DOI: 10.5999/aps.2015.42.1.78

Source DB:  PubMed          Journal:  Arch Plast Surg        ISSN: 2234-6163


  13 in total

Review 1.  An overview of methods for vascular mapping in the planning of free flaps.

Authors:  Jeroen M Smit; Steven Klein; Paul M N Werker
Journal:  J Plast Reconstr Aesthet Surg       Date:  2010-07-31       Impact factor: 2.740

2.  Anatomic imaging of abdominal perforator flaps without ionizing radiation: seeing is believing with magnetic resonance imaging angiography.

Authors:  David Greenspun; Julie Vasile; Joshua L Levine; Heather Erhard; Rebecca Studinger; Victoria Chernyak; Tiffany Newman; Martin Prince; Robert J Allen
Journal:  J Reconstr Microsurg       Date:  2009-05-18       Impact factor: 2.873

3.  Computed tomography angiography imaging for the chimeric anterolateral thigh flap in reconstruction of full thickness buccal defect.

Authors:  Wen-Kuan Chiu; Wen-Chiung Lin; Shih-Yi Chen; Wei-Da Tzeng; Shao-Cheng Liu; Tzu-Peng Lee; Shyi-Gen Chen
Journal:  ANZ J Surg       Date:  2010-09-16       Impact factor: 1.872

4.  The value of preoperative Doppler sonography for planning free perforator flaps.

Authors:  R E Giunta; A Geisweid; A M Feller
Journal:  Plast Reconstr Surg       Date:  2000-06       Impact factor: 4.730

5.  Preoperative planning of deep inferior epigastric artery perforator flap reconstruction with multislice-CT angiography: imaging findings and initial experience.

Authors:  A Alonso-Burgos; E García-Tutor; G Bastarrika; D Cano; A Martínez-Cuesta; L J Pina
Journal:  J Plast Reconstr Aesthet Surg       Date:  2006-03-22       Impact factor: 2.740

6.  Multidetector-row computed tomography in the planning of abdominal perforator flaps.

Authors:  J Masia; J A Clavero; J R Larrañaga; X Alomar; G Pons; P Serret
Journal:  J Plast Reconstr Aesthet Surg       Date:  2006-02-28       Impact factor: 2.740

7.  Colour Doppler assessment of the perforators of anterolateral thigh flap and its usefulness in preoperative planning.

Authors:  Łukasz Ulatowski
Journal:  Pol Przegl Chir       Date:  2012-03

8.  Use of angioscanning in the surgical planning of perforator flaps in the lower extremities.

Authors:  M C Higueras Suñé; A López Ojeda; J A Narváez García; M De Albert De Las Vigo; O Roca Mas; D Perez Sidelnikova; C Carrasco López; J A Palacin Porte; J M Serra Payró; J M Viñals
Journal:  J Plast Reconstr Aesthet Surg       Date:  2011-04-07       Impact factor: 2.740

9.  Osmotic determinants of postlens tear film morphology and hydrogel lens movement.

Authors:  S A Little; A S Bruce
Journal:  Ophthalmic Physiol Opt       Date:  1995-03       Impact factor: 3.117

10.  MDCT in the preoperative planning of abdominal perforator surgery for postmastectomy breast reconstruction.

Authors:  Juan A Clavero; Jaume Masia; Jose Larrañaga; Josep M Monill; Gemma Pons; Sahyly Siurana; Xavier Alomar
Journal:  AJR Am J Roentgenol       Date:  2008-09       Impact factor: 3.959

View more
  3 in total

1.  Photoacoustic microscopy: a novel approach for studying perforator skin flap in a mouse model.

Authors:  Dong Zhang; Hairen Chen; Xiang Hu; Aixi Yu
Journal:  Quant Imaging Med Surg       Date:  2021-10

2.  Through the HoloLens™ looking glass: augmented reality for extremity reconstruction surgery using 3D vascular models with perforating vessels.

Authors:  Philip Pratt; Matthew Ives; Graham Lawton; Jonathan Simmons; Nasko Radev; Liana Spyropoulou; Dimitri Amiras
Journal:  Eur Radiol Exp       Date:  2018-01-31

3.  Safety and Vascular Impact of Perforator Propeller Flaps during Distal Lower Limb Reconstruction.

Authors:  Tarek Eldahshoury; Roberto Cacciola; Khaled El-Gazzar
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-12-17
  3 in total