Literature DB >> 25601953

Hypersensitivity reaction in the US Food and Drug Administration-approved second-generation drug-eluting stents: histopathological assessment with ex vivo optical coherence tomography.

Fumiyuki Otsuka1, Kazuyuki Yahagi1, Elena Ladich1, Robert Kutys1, Russell Alexander1, David Fowler1, Renu Virmani1, Michael Joner2.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25601953     DOI: 10.1161/CIRCULATIONAHA.114.012658

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


× No keyword cloud information.
  9 in total

Review 1.  Bioresorbable Polymers and Stent Devices.

Authors:  Payam Dehghani
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-02

Review 2.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

3.  Prospective evaluation of an ultrathin strut biodegradable polymer-coated sirolimus-eluting stent: 12 months' results from the S-FLEX UK registry.

Authors:  Anirban Choudhury; Scot Garg; Jamie Smith; Andrew Sharp; Sergio Nabais de Araujo; Anoop Chauhan; Nikhil Patel; Benjamin Wrigley; Sudipta Chattopadhyay; Azfar G Zaman
Journal:  BMJ Open       Date:  2019-10-11       Impact factor: 2.692

4.  Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report.

Authors:  Takahiro Jimba; Takehiro Hashikata; Masashiro Matsushita; Masao Yamasaki
Journal:  Eur Heart J Case Rep       Date:  2020-02-04

Review 5.  Hypersensitivity and in-stent restenosis in coronary stent materials.

Authors:  Wansong Hu; Jun Jiang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-15

6.  Histopathological evaluation of thrombus in patients presenting with stent thrombosis. A multicenter European study: a report of the prevention of late stent thrombosis by an interdisciplinary global European effort consortium.

Authors:  Julia Riegger; Robert A Byrne; Michael Joner; Sue Chandraratne; Anthony H Gershlick; Jurrien M Ten Berg; Tom Adriaenssens; Giulio Guagliumi; Thea C Godschalk; Franz-Josef Neumann; Dietmar Trenk; Laurent J Feldman; Philippe Gabriel Steg; Walter Desmet; Fernando Alfonso; Alison H Goodall; Roman Wojdyla; Dariusz Dudek; Vanessa Philippi; Sheryl Opinaldo; Anna Titova; Nikesh Malik; James Cotton; Darshni A Jhagroe; Antonius A C M Heestermans; Peter Sinnaeve; Paul Vermeersch; Christian Valina; Christian Schulz; Adnan Kastrati; Steffen Massberg
Journal:  Eur Heart J       Date:  2015-08-30       Impact factor: 29.983

7.  Coronary Artery Vessel Healing Pattern, Short and Long Term, After Implantation of the Everolimus-Eluting Bioresorbable Vascular Scaffold.

Authors:  Robin P Kraak; Hans H de Boer; Joëlle Elias; Carmen A Ambarus; Allard C van der Wal; Robbert J de Winter; Joanna J Wykrzykowska
Journal:  J Am Heart Assoc       Date:  2015-11-09       Impact factor: 5.501

8.  Everolimus-Eluting Biodegradable Abluminal Coating Stent versus Durable Conformal Coating Stent: Termination of the Inflammatory Response Associated with Neointimal Healing in a Porcine Coronary Model.

Authors:  Masayuki Mori; Kenji Sakata; Junichiro Yokawa; Chiaki Nakanishi; Kota Murai; Hirofumi Okada; Masaya Shimojima; Shohei Yoshida; Kazuaki Yoshioka; Yoh Takuwa; Kenshi Hayashi; Masakazu Yamagishi; Masa-Aki Kawashiri
Journal:  J Interv Cardiol       Date:  2020-04-27       Impact factor: 2.279

9.  The Association Between S100A8/A9 and the Development of Very Late Stent Thrombosis in Patients With Acute Myocardial Infarction.

Authors:  Xiang Wang; Meng Guan; Xiuhang Zhang; Taiyuan Ma; Muli Wu; Yulin Li; Xinxin Chen; Yang Zheng
Journal:  Clin Appl Thromb Hemost       Date:  2020 Jan-Dec       Impact factor: 2.389

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.