Literature DB >> 25601499

Geometry and respiratory-induced deformation of abdominal branch vessels and stents after complex endovascular aneurysm repair.

Brant W Ullery1, Ga-Young Suh2, Jason T Lee2, Brian Liu2, Robert Stineman3, Ronald L Dalman2, Christopher P Cheng2.   

Abstract

OBJECTIVE: This study quantified the geometry and respiration-induced deformation of abdominal branch vessels and stents after fenestrated (F-) and snorkel (Sn-) endovascular aneurysm repair (EVAR).
METHODS: Twenty patients (80% male; mean age, 75.2 ± 7.4 years; mean aneurysm diameter, 6.2 ± 1.8 cm) underwent computed tomography angiography during inspiratory and expiratory breath hold protocols after F-EVAR (n = 11) or Sn-EVAR (n = 9). Centerlines for the aorta and visceral vessels were extracted from three-dimensional models. Branch angles were computed relative to the orthogonal plane at the branch ostia, and end-stent angles of the left renal artery (LRA) and right renal artery (RRA) were computed relative to the distal stent orientation. The radius of peak curvature was defined by the circumscribed circle at the highest curvature.
RESULTS: Sn-renal branches were more downward-angled than F-renal branches (P < .04). At the distal ends of the RRA stents, Sn-RRAs were angled greater than F-RRAs (P < .03) and had a smaller radius of peak curvature (P < .03). With expiration, the end-stent angle of Sn-LRAs increased by 4° ± 4° (P < .02) and exhibited a significant reduction of radius of curvature (P < .04). The unstented celiac arteries were more downward-angled (P < .02, inspiration), with a smaller radius of curvature (P < .00001), than the unstented superior mesenteric arteries. With expiration, the celiac arteries angled upwards by 9° ± 9° (P < .0005), which was greater than the superior mesenteric arteries (P < .03). At a median postoperative follow-up of 12.6 months (range, 1.0-37.1 months), branch vessel patency was 100%, serum creatinine levels remained stable, and one reintervention was required for a type III endoleak at the main body-LRA stent interface.
CONCLUSIONS: Sn-renals were angled more inferiorly at the branch and more angulated at the stent end than F-renals due to stent placement strategies. Sn-LRAs exhibited a significant change in end-stent angle and curvature during respiration, a finding that may compromise long-term durability for parallel stent graft configurations. Further investigation is warranted to better optimize anatomic, patient, and branch vessel stent selection between fenestrated and snorkel strategies and their relationship to long-term patency.
Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25601499     DOI: 10.1016/j.jvs.2014.11.075

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  5 in total

1.  Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration.

Authors:  Ga-Young Suh; Gilwoo Choi; Robert J Herfkens; Ronald L Dalman; Christopher P Cheng
Journal:  Ann Vasc Surg       Date:  2016-04-24       Impact factor: 1.466

2.  A Lagrangian cylindrical coordinate system for characterizing dynamic surface geometry of tubular anatomic structures.

Authors:  Torbjörn Lundh; Ga-Young Suh; Phillip DiGiacomo; Christopher Cheng
Journal:  Med Biol Eng Comput       Date:  2018-03-03       Impact factor: 2.602

3.  Structural failure in bridging stentgrafts for branched endovascular aneurysm repair: a case-control study.

Authors:  Sven R Hauck; Alexander Kupferthaler; Martin C Freund; Peter Pichler; Marie-Elisabeth Stelzmüller; Christopher Burghuber; Marek Ehrlich; Harald Teufelsbauer; Christian Loewe; Martin A Funovics
Journal:  Insights Imaging       Date:  2022-03-28

4.  Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions.

Authors:  Harkamaljot Kandail; Mohamad Hamady; Xiao Yun Xu
Journal:  J Endovasc Ther       Date:  2016-05-25       Impact factor: 3.487

5.  Stabilization of the Abdominal Aorta During the Cardiac Cycle with the Sac-Anchoring Nellix Device.

Authors:  Nathan K Itoga; Ga-Young Suh; Christopher P Cheng
Journal:  Ann Vasc Surg       Date:  2018-06-09       Impact factor: 1.466

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.