Real-Time Detection of Telomerase Activity in Cancer Cells using a Label-Free Electrochemical Impedimetric Biosensing Microchip.

Lisandro Cunci1, Marina Martinez Vargas2, Roman Cunci3, Ramon Gomez-Moreno2, Ivan Perez1, Abel Baerga-Ortiz2, Carlos I Gonzalez4, Carlos R Cabrera1.   

Abstract

The enzyme telomerase is present in about 85% of human cancers which makes it not only a good target for cancer treatment but also an excellent marker for cancer detection. Using a single stranded DNA probe specific for telomerase binding and reverse transcription tethered to an interdigital gold electrode array surface, the chromosome protection provided by the telomerase was replicated and followed by Electrochemical Impedance Spectroscopy as an unlabeled biosensor. Using this system designed in-house, easy and affordable, impedance measurements were taken while incubating at 37 °C and promoting the probe elongation. This resulted in up to 14-fold increase in the charge transfer resistance when testing a telomerase-positive nuclear extract from Jurkat cells compared to the heat-inactivated telomerase-negative nuclear extract. The electron transfer process at the Au electrodes was studied before the elongation, at different times after the elongation, and after desorption of non-specific binding.

Entities:  

Keywords:  Biosensor; EIS; Interdigital electrode; Microchip; Telomerase

Year:  2014        PMID: 25598969      PMCID: PMC4295792          DOI: 10.1039/C4RA09689D

Source DB:  PubMed          Journal:  RSC Adv        ISSN: 2046-2069            Impact factor:   3.361


  34 in total

1.  Restoration of T cell receptor-mediated signal transduction by transfection of CD45 cDNA into a CD45-deficient variant of the Jurkat T cell line.

Authors:  G A Koretzky; M A Kohmetscher; T Kadleck; A Weiss
Journal:  J Immunol       Date:  1992-08-15       Impact factor: 5.422

2.  Catalytic beacons for the detection of DNA and telomerase activity.

Authors:  Yi Xiao; Valeri Pavlov; Tamara Niazov; Arnon Dishon; Moshe Kotler; Itamar Willner
Journal:  J Am Chem Soc       Date:  2004-06-23       Impact factor: 15.419

3.  Inherently electroactive graphene oxide nanoplatelets as labels for single nucleotide polymorphism detection.

Authors:  Alessandra Bonanni; Chun Kiang Chua; Guanjia Zhao; Zdeněk Sofer; Martin Pumera
Journal:  ACS Nano       Date:  2012-09-25       Impact factor: 15.881

4.  Highly sensitive detection of telomerase based on a DNAzyme strategy.

Authors:  Tian Tian; Shuang Peng; Heng Xiao; Xiaoe Zhang; Shan Guo; Shaoru Wang; Xiang Zhou; Songmei Liu; Xin Zhou
Journal:  Chem Commun (Camb)       Date:  2013-04-04       Impact factor: 6.222

5.  A robust probe for lighting up intracellular telomerase via primer extension to open a nicked molecular beacon.

Authors:  Ruocan Qian; Lin Ding; Liwen Yan; Manfei Lin; Huangxian Ju
Journal:  J Am Chem Soc       Date:  2014-05-29       Impact factor: 15.419

Review 6.  Alternative lengthening of telomeres: models, mechanisms and implications.

Authors:  Anthony J Cesare; Roger R Reddel
Journal:  Nat Rev Genet       Date:  2010-03-30       Impact factor: 53.242

7.  Graphene platform for hairpin-DNA-based impedimetric genosensing.

Authors:  Alessandra Bonanni; Martin Pumera
Journal:  ACS Nano       Date:  2011-02-28       Impact factor: 15.881

8.  Label-free detection of telomerase activity using guanine electrochemical oxidation signal.

Authors:  Ugur Eskiocak; Dilsat Ozkan-Ariksoysal; Mehmet Ozsoz; Huseyin Avni Oktem
Journal:  Anal Chem       Date:  2007-10-11       Impact factor: 6.986

9.  Real-time detection of telomerase activity using the exponential isothermal amplification of telomere repeat assay.

Authors:  Leilei Tian; Yossi Weizmann
Journal:  J Am Chem Soc       Date:  2012-12-03       Impact factor: 15.419

10.  Jurkat T cells express a functional neutral endopeptidase activity (CALLA) involved in T cell activation.

Authors:  B Mari; F Checler; G Ponzio; J F Peyron; S Manie; D Farahifar; B Rossi; P Auberger
Journal:  EMBO J       Date:  1992-11       Impact factor: 11.598

View more
  8 in total

1.  A PCR-free voltammetric telomerase activity assay using a substrate primer on a gold electrode and DNA-triggered capture of gold nanoparticles.

Authors:  Fanyu Meng; Yuanyuan Xu; Wenfei Dong; Yuguo Tang; Peng Miao
Journal:  Mikrochim Acta       Date:  2018-08-01       Impact factor: 5.833

2.  Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

Authors:  Nilka Rivera-Serrano; Miraida Pagan; Joanisse Colón-Rodríguez; Christian Fuster; Román Vélez; Jose Almodovar-Faria; Carlos Jiménez-Rivera; Lisandro Cunci
Journal:  Anal Chem       Date:  2018-01-04       Impact factor: 6.986

3.  Measurement of Neuropeptide Y Using Aptamer-Modified Microelectrodes by Electrochemical Impedance Spectroscopy.

Authors:  Luis López; Nerika Hernández; Joshua Reyes Morales; John Cruz; Krystal Flores; John González-Amoretti; Vitmary Rivera; Lisandro Cunci
Journal:  Anal Chem       Date:  2020-12-10       Impact factor: 6.986

4.  Real-time Detection of Breast Cancer Cells Using Peptide-functionalized Microcantilever Arrays.

Authors:  Hashem Etayash; Keren Jiang; Sarfuddin Azmi; Thomas Thundat; Kamaljit Kaur
Journal:  Sci Rep       Date:  2015-10-05       Impact factor: 4.379

Review 5.  Advances in the detection of telomerase activity using isothermal amplification.

Authors:  Xiaojin Zhang; Xiaoding Lou; Fan Xia
Journal:  Theranostics       Date:  2017-04-10       Impact factor: 11.556

6.  Label-Free Telomerase Activity Detection via Electrochemical Impedance Spectroscopy.

Authors:  Diana C Díaz-Cartagena; Griselle Hernández-Cancel; Dina P Bracho-Rincón; José A González-Feliciano; Lisandro Cunci; Carlos I González; Carlos R Cabrera
Journal:  ACS Omega       Date:  2019-10-01

7.  Test Strip Platform Spin-Off for Telomerase Activity Detection: Development of an Electrochemical Biosensor.

Authors:  Ramonita Díaz-Ayala; Marjorie López-Nieves; Etienne S Colón Berlingeri; Carlos R Cabrera; Lisandro Cunci; Carlos I González; Pedro F Escobar
Journal:  ACS Omega       Date:  2022-03-09

8.  Multicolor Fluorescent Graphene Oxide Quantum Dots for Sensing Cancer Cell Biomarkers.

Authors:  Lisandro Cunci; Viviana González-Colón; Brenda Lee Vargas-Pérez; Joed Ortiz-Santiago; Miraida Pagán; Paola Carrion; Jomari Cruz; Agustin Molina-Ontoria; Namyr Martinez; Walter Silva; Luis Echegoyen; Carlos R Cabrera
Journal:  ACS Appl Nano Mater       Date:  2020-12-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.