Measuring intraocular pressure.

Kingsley C Okafor1, James D Brandt.   

Abstract

PURPOSE OF REVIEW: Tonometry is undergoing a long-overdue renaissance. Goldmann applanation tonometry (GAT) is 50-year-old technology. Although GAT is considered a 'reference standard', it has many limitations and confounders. This review compares GAT to some of the newer technologies that have recently been commercialized or are in development. RECENT
FINDINGS: Dynamic contour tonometry is fairly cornea-independent, but requires technical skill to carry out. Rebound tonometry requires no anesthetic and is particularly useful in children. The ocular response analyzer quantifies corneal biomechanical factors and provides other useful measures relevant to glaucoma risk. A transpalpebral tonometer that claims to measure intraocular pressure (IOP) through the closed eyelid has been introduced, but studies comparing it to conventional tonometers suggest it is too unreliable for routine use. Various new technologies including IOP-sensing contact lenses and implantable sensors are in clinical evaluation.
SUMMARY: There is no perfect tonometer, and clinicians must choose which to use in their daily practice, balancing accuracy, precision, convenience, and cost. Clinicians should recognize that a single IOP measurement is but an often error-prone snapshot of a widely varying physiologic parameter. IOP data should only be used in the context of the overall clinical picture.

Entities:  

Mesh:

Year:  2015        PMID: 25594767     DOI: 10.1097/ICU.0000000000000129

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  15 in total

1.  Does patient comfort influence the choice of tonometer for the measurement of intraocular pressure?

Authors:  Mary O Ugalahi; Mukaila A Seidu; Bolutife A Olusanya; Aderonke M Baiyeroju
Journal:  Int Ophthalmol       Date:  2015-10-16       Impact factor: 2.031

2.  Association of Long-term Ambient Black Carbon Exposure and Oxidative Stress Allelic Variants With Intraocular Pressure in Older Men.

Authors:  Jamaji C Nwanaji-Enwerem; Weiye Wang; Onyemaechi Nwanaji-Enwerem; Pantel Vokonas; Andrea Baccarelli; Marc Weisskopf; Leon W Herndon; Janey L Wiggs; Sung Kyun Park; Joel Schwartz
Journal:  JAMA Ophthalmol       Date:  2019-02-01       Impact factor: 7.389

3.  Evaluation of Corvis ST tonometer with the updated software in glaucoma practice.

Authors:  Ioannis Halkiadakis; Vasilios Tzimis; Alexandros Gryparis; Ioannis Markopoulos; Vasiliki Konstadinidou; Elias Zintzaras; Michalis Tzakos
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

4.  The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods.

Authors:  Ahmed Lubbad; Irene Oluwatoba-Popoola; Melanie Haar; Carsten Framme; Anna Bajor
Journal:  Int Ophthalmol       Date:  2022-01-13       Impact factor: 2.029

5.  Spectral analysis of intraocular pressure pulse wave in ocular hypertensive and primary open angle glaucoma patients.

Authors:  Marija M Bozic; Miroslav L Dukic; Milenko Z Stojkovic
Journal:  Indian J Ophthalmol       Date:  2016-02       Impact factor: 1.848

Review 6.  An Update on the Ophthalmologic Features in the Phakomatoses.

Authors:  Solmaz Abdolrahimzadeh; Andrea Maria Plateroti; Santi Maria Recupero; Alessandro Lambiase
Journal:  J Ophthalmol       Date:  2016-07-17       Impact factor: 1.909

7.  Biomechanical Simulation of Stress Concentration and Intraocular Pressure in Corneas Subjected to Myopic Refractive Surgical Procedures.

Authors:  Po-Jen Shih; I-Jong Wang; Wen-Feng Cai; Jia-Yush Yen
Journal:  Sci Rep       Date:  2017-10-24       Impact factor: 4.379

8.  Dual Optical Signal-based Intraocular Pressure-sensing Principle Using Pressure-sensitive Mechanoluminescent ZnS:Cu/PDMS Soft Composite.

Authors:  Yooil Kim; Sunanda Roy; Gwang-Yong Jung; Jung-Sik Oh; Gi-Woo Kim
Journal:  Sci Rep       Date:  2019-10-23       Impact factor: 4.379

9.  Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty.

Authors:  Oded Ohana; David Varssano; Gabi Shemesh
Journal:  Indian J Ophthalmol       Date:  2017-07       Impact factor: 1.848

10.  Effect of Hemifacial Spasm on Intraocular Pressure Measurement.

Authors:  Erdogan Cicik; Rengin Yildirim; Ceyhun Arici; Funda Dikkaya; Osman Sevki Arslan
Journal:  J Ophthalmol       Date:  2018-02-06       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.