Performance and acceptability of a combined device for insulin infusion and glucose sensing in the home setting.

Kirsten Nørgaard1, John Shin2, John B Welsh3, Hans Gjessing4.   

Abstract

The use of sensor-augmented insulin pump (SAP) therapy is increasing. Currently, glucose sensors and insulin infusion cannulas are inserted separately. A new device, MiniMed Duo, combines sensing and infusion capabilities on the same platform and is intended to simplify device insertion and site management. We evaluated the device's performance with respect to insulin delivery and glucose sensing, and its acceptability with patients. Forty-five patients (mean ± SD age, 45.5 ± 10.9 years, 48% female) with type 1 diabetes and previous use of SAP participated. Each subject was to wear 5 devices connected to insulin pumps over 15 days (3 days/device) and test capillary blood glucose (SMBG) 7 times/day. The primary endpoint was the percentage of sensor-SMBG paired values within 20% of one another. Subject experiences were assessed via questionnaires. Overall, 74.8% of sensor-SMBG paired values were within 20%, meeting the primary accuracy endpoint, and the mean absolute relative difference was 15.5 ± 17.1%. Consensus error grid analysis showed that >95% of points were within the A+B zones, exceeding the threshold for adequate clinical accuracy. Insulin dosage and SMBG values did not change significantly compared to prestudy values. The functional survival of the device entering day 3 was 90.5%. There were no serious adverse events. Mean questionnaire results indicated overall satisfaction with the device. Duo provided insulin infusion and glucose sensing capabilities in a single device, which provided accurate glucose readings during routine use, was safe to wear, and was acceptable to most patients. It may improve satisfaction and convenience for patients using sensor-augmented insulin pumps.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  accuracy; combo-set; continuous glucose monitoring; duo; insulin infusion

Mesh:

Substances:

Year:  2015        PMID: 25591857      PMCID: PMC4604571          DOI: 10.1177/1932296814567326

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  11 in total

1.  Accuracy and reliability of continuous glucose monitoring systems: a head-to-head comparison.

Authors:  Yoeri M Luijf; Julia K Mader; Werner Doll; Thomas Pieber; Anne Farret; Jerome Place; Eric Renard; Daniela Bruttomesso; Alessio Filippi; Angelo Avogaro; Sabine Arnolds; Carsten Benesch; Lutz Heinemann; J Hans DeVries
Journal:  Diabetes Technol Ther       Date:  2013-05-07       Impact factor: 6.118

2.  Routine sensor-augmented pump therapy in type 1 diabetes: the INTERPRET study.

Authors:  Kirsten Nørgaard; Andrea Scaramuzza; Natasa Bratina; Nebojsa M Lalić; Przemyslaw Jarosz-Chobot; Győző Kocsis; Edita Jasinskiene; Christophe De Block; Odile Carrette; Javier Castañeda; Ohad Cohen
Journal:  Diabetes Technol Ther       Date:  2013-02-25       Impact factor: 6.118

3.  Diabetes care entering 2014: more ranting.

Authors:  Irl B Hirsch
Journal:  Diabetes Technol Ther       Date:  2014-02       Impact factor: 6.118

4.  Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.

Authors:  Timothy S Bailey; Andrew Ahmann; Ronald Brazg; Mark Christiansen; Satish Garg; Elaine Watkins; John B Welsh; Scott W Lee
Journal:  Diabetes Technol Ther       Date:  2014-04-07       Impact factor: 6.118

5.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

6.  Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes.

Authors:  Richard M Bergenstal; William V Tamborlane; Andrew Ahmann; John B Buse; George Dailey; Stephen N Davis; Carol Joyce; Tim Peoples; Bruce A Perkins; John B Welsh; Steven M Willi; Michael A Wood
Journal:  N Engl J Med       Date:  2010-06-29       Impact factor: 91.245

7.  Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial.

Authors:  J Hermanides; K Nørgaard; D Bruttomesso; C Mathieu; A Frid; C M Dayan; P Diem; C Fermon; I M E Wentholt; J B L Hoekstra; J H DeVries
Journal:  Diabet Med       Date:  2011-10       Impact factor: 4.359

8.  Less severe hypoglycaemia, better metabolic control, and improved quality of life in Type 1 diabetes mellitus with continuous subcutaneous insulin infusion (CSII) therapy; an observational study of 100 consecutive patients followed for a mean of 2 years.

Authors:  R Linkeschova; M Raoul; U Bott; M Berger; M Spraul
Journal:  Diabet Med       Date:  2002-09       Impact factor: 4.359

9.  Effect of insulin catheter wear-time on subcutaneous adipose tissue blood flow and insulin absorption in humans.

Authors:  Trine Schnedler Clausen; Peter Kaastrup; Bente Stallknecht
Journal:  Diabetes Technol Ther       Date:  2009-09       Impact factor: 6.118

10.  Accuracy of two continuous glucose monitoring systems: a head-to-head comparison under clinical research centre and daily life conditions.

Authors:  J Kropff; D Bruttomesso; W Doll; A Farret; S Galasso; Y M Luijf; J K Mader; J Place; F Boscari; T R Pieber; E Renard; J H DeVries
Journal:  Diabetes Obes Metab       Date:  2014-09-10       Impact factor: 6.577

View more
  10 in total

Review 1.  Moving Toward a Unified Platform for Insulin Delivery and Sensing of Inputs Relevant to an Artificial Pancreas.

Authors:  Anneke Graf; Sybil A McAuley; Catriona Sims; Johanna Ulloa; Alicia J Jenkins; Gayane Voskanyan; David N O'Neal
Journal:  J Diabetes Sci Technol       Date:  2016-12-13

2.  Benefits and Limitations of MARD as a Performance Parameter for Continuous Glucose Monitoring in the Interstitial Space.

Authors:  Lutz Heinemann; Michael Schoemaker; Günther Schmelzeisen-Redecker; Rolf Hinzmann; Adham Kassab; Guido Freckmann; Florian Reiterer; Luigi Del Re
Journal:  J Diabetes Sci Technol       Date:  2019-06-19

3.  Insulin Infusion Sets and Continuous Glucose Monitoring Sensors: Where the Artificial Pancreas Meets the Patient.

Authors:  Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2017-04       Impact factor: 6.118

Review 4.  Diabetes Technology: Uptake, Outcomes, Barriers, and the Intersection With Distress.

Authors:  Diana Naranjo; Molly L Tanenbaum; Esti Iturralde; Korey K Hood
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

Review 5.  Current Status and Emerging Options for Automated Insulin Delivery Systems.

Authors:  Gregory P Forlenza; Rayhan A Lal
Journal:  Diabetes Technol Ther       Date:  2022-03-14       Impact factor: 7.337

6.  Duration of Infusion Set Survival in Lipohypertrophy Versus Nonlipohypertrophied Tissue in Patients with Type 1 Diabetes.

Authors:  Andrew W Karlin; Trang T Ly; Laura Pyle; Gregory P Forlenza; Laurel Messer; R Paul Wadwa; Daniel J DeSalvo; Sydney L Payne; Sarah Hanes; Paula Clinton; David M Maahs; Bruce Buckingham
Journal:  Diabetes Technol Ther       Date:  2016-05-26       Impact factor: 6.118

7.  Insulin Delivery Hardware: Pumps and Pens.

Authors:  Rayhan A Lal; Lalantha Leelarathna
Journal:  Diabetes Technol Ther       Date:  2021-06       Impact factor: 7.337

8.  Longevity of the novel ConvaTec infusion set with Lantern technology.

Authors:  Rayhan A Lal; Liana Hsu; Jian Zhang; Pernelle K Schøndorff; Matthias Heschel; Bruce Buckingham
Journal:  Diabetes Obes Metab       Date:  2021-04-18       Impact factor: 6.408

9.  A comprehensive microbiological safety approach for agarose encapsulated porcine islets intended for clinical trials.

Authors:  Lawrence S Gazda; James Collins; Archie Lovatt; Robert W Holdcraft; Merribeth J Morin; Daniel Galbraith; Melanie Graham; Melissa A Laramore; Christine Maclean; John Black; Euan W Milne; Douglas G Marthaler; Horatiu V Vinerean; Michelle M Michalak; Deborah Hoffer; Steven Richter; Richard D Hall; Barry H Smith
Journal:  Xenotransplantation       Date:  2016-11-11       Impact factor: 3.907

Review 10.  Glycemic Status Assessment by the Latest Glucose Monitoring Technologies.

Authors:  Ilaria Malandrucco; Benedetta Russo; Fabiana Picconi; Marika Menduni; Simona Frontoni
Journal:  Int J Mol Sci       Date:  2020-11-03       Impact factor: 5.923

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.