| Literature DB >> 25590446 |
Juliana A Sedrez1, Cláudia T Candotti1, Fernanda S Medeiros1, Mariana T Marques1, Maria I Z Rosa1, Jefferson F Loss1.
Abstract
BACKGROUND: The adapted arcometer has been validated for use in adults. However, its suitability for use in children can be questioned given the structural differences present in these populations.Entities:
Mesh:
Year: 2014 PMID: 25590446 PMCID: PMC4311598 DOI: 10.1590/bjpt-rbf.2014.0060
Source DB: PubMed Journal: Braz J Phys Ther ISSN: 1413-3555 Impact factor: 3.377
Figure 1The adapted arcometer being used to measure thoracic kyphosis. H1: distance between T1 spinal process and the apex of the curvature. H2: distance between the apex of the curvature and T12 spinal process. FA, f and FB: upper rod, central rod and lower rod, respectively.
Figure 2Schematic diagram showing the evaluations conducted using the adapted arcometer and X-rays.
Average values and standard deviations (SD) of the different evaluations made with X-ray and adapted arcometer.
| Evaluated aspect | Evaluation | Thoracic kyphosis | Lumbar lordosis | ||
|---|---|---|---|---|---|
| Average±SD (°) | p | Average±SD (°) | p | ||
| Concurrent validity | X-ray | 49.4±11.2 | 0.131a | 42.1±8.7 | 0.070b |
| Evaluator A | 53.6±11.5 | 39.7±22.2 | |||
| Repeatability | Evaluator A | 53.6±11.5 | 0.349a | 39.7±22.2 | 0.791b |
| Evaluation A | 51.8±12.1 | 39.1±19.8 | |||
| Inter-evaluator reproducibility | Evaluation A | 51.8±12.1 | 0.640a | 39.1±19.8 | 0.361b |
| Evaluator B | 53.2±8.8 | 36.3±19.0 | |||
| Intra-evaluator reproducibility | Evaluator B | 53.2±8.8 | 0.643a | 36.3±19.0 | 0.762b |
| Evaluator B | 53.2±10.1 | 30.5±18.2 | |||
aPaired t test
bWilcoxon test.
Statistical results referring to the correlations between the different evaluations.
| Region | Evaluated aspect | Variable | Correlation test | p |
|---|---|---|---|---|
| Thoracic kyphosis | Concurrent validity | X-ray vs. Eva A (1st) | 0.407a | 0.009* |
| Repeatability | Eva A (1st) vs. Eva A (2nd) | 0.439b | 0.002* | |
| Inter-evaluator reproducibility | Eva A (2nd) vs. Eva B (1st) | 0.257b | 0.052 | |
| Intra-evaluator reproducibility | Eva B (1st) vs. Eva B (2nd) | 0.504b | 0.001* | |
| Lumbar lordosis | Concurrent validity | X-ray vs. Eva A (1st) | 0.037c | 0.983 |
| Repeatability | Eva A (1st) vs. Eva A (2nd) | 0.445b | 0.002* | |
| Inter-evaluator reproducibility | Eva A (2nd) vs. Eva B (1st) | 0.258b | 0.052 | |
| Intra-evaluator reproducibility | Eva B (1st) vs. Eva B (2nd) | 0.433b | 0.003* |
Eva A - evaluator A; Eva B - evaluator B; 1st - first evaluation; 2nd - second evaluation
aPearson's r
bICC
cSpearman's rho
*significant correlation (p<0.05).