Literature DB >> 22522063

Validating a postural evaluation method developed using a Digital Image-based Postural Assessment (DIPA) software.

Tássia Silveira Furlanetto, Cláudia Tarragô Candotti, Tatiana Comerlato, Jefferson Fagundes Loss.   

Abstract

OBJECTIVE: To investigate (1) the accuracy of the palpatory method to identify anatomical points by comparison with the X-ray exams, (2) the validity of classifying spinal posture in the frontal plane using Digital Image-Based Postural Assessment (DIPA) software by comparison with the X-ray exams and (3) the intra and inter-evaluator reproducibility of the DIPA software.
MATERIALS AND METHODS: The postural assessment and X-ray examination of the spine, both in the frontal plane and standing position, were performed consecutively in 24 subjects. The postural assessment protocol consisted of: (1) palpation and the use of reflective markers containing lead to mark the spinous processes (SP) of the C7, T2, T4, T6, T8, T10, T12, L2, L4 and S2 vertebrae and; (2) acquisition of photographic records. First, the X-ray examinations were used to check the correlation between the palpated and marked SP and the true location of the SP of the vertebra in question, by assessing the distance between them. The spinal posture was classified based on the calculation of the scoliosis arrows in the DIPA (DIPA-SA). The X-ray examinations provided the scoliosis arrows (X-SA), the Cobb angles and the classification of spinal posture based on the Cobb angle. The results from the DIPA protocol were compared to those from the X-ray examination-based protocol. The statistical tests used were: (1) Kruskal-Wallis--differences in terms of the numerical distance between the markers and the anatomical landmarks, (2) Pearson's Correlation--DIPA-SA and Cobb angles, (3) Pearson's Correlation--X-SA and DIPA-SA; (4) Bland and Altman's graphic representation--X-SA and DIPA-SA, (5) Spearman's Correlation--classification of spinal posture obtained using the X-ray and DIPA protocols, (6) the intraclass correlation test (ICC) for the relationship between the DIPA-SA made by each evaluator (inter-evaluator), and (7) independent t-test to compare the data from the two evaluation days (intra-evaluator), α=0.05.
RESULTS: There were no significant differences between the location of the anatomical points located using palpation and identified with reflective markers and the respective location of the SP as identified using X-ray exams (χ²=9.366, p=0.404). Significant correlations were found between the DIPA-SA and the Cobb angles in the dorsal (r=0.75, p<0.001) and lumbar (r=0.76, p=0.007) regions; between the DIPA-SA and the X-SA in the dorsal (r=0.79, p<0.001) and lumbar (r=0.92, p<0.001) regions and; between the classifications of posture obtained with the DIPA and X-ray protocols (r=0.804, p<0.001). Bland and Altman's representation showed agreement between DIPA-SA and X-SA for both curvatures. Significant correlations were found for the intra-evaluator test in the thoracic (r=0.99, p<0.001) and lumbar (r=0.98, p<0.001) regions; for the inter-evaluator test in the thoracic (r=0.99, p<0.001) and lumbar (r=0.88, p<0.001) regions.
CONCLUSION: The results suggest that the DIPA protocol constitutes a valid simple, practical and low-cost non-invasive tool for the evaluation of the spine in the frontal plane which can be used to obtain reproducible measurements (inter and intra-evaluators).
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22522063     DOI: 10.1016/j.cmpb.2012.03.012

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  9 in total

1.  Would adopting a revised landmark rule for the spinal level of the iliac crests improve the accuracy of lumbar level identification?

Authors:  Robert Cooperstein; Felisha Truong
Journal:  J Can Chiropr Assoc       Date:  2019-04

2.  Photogrammetry as a tool for the postural evaluation of the spine: A systematic review.

Authors:  Tássia Silveira Furlanetto; Juliana Adami Sedrez; Cláudia Tarragô Candotti; Jefferson Fagundes Loss
Journal:  World J Orthop       Date:  2016-02-18

3.  Validation of a Mathematical Procedure for the Cobb Angle Assessment Based on Photogrammetry.

Authors:  Isis Juliene Rodrigues Leite Navarro; Cláudia T Candotti; Tássia S Furlanetto; Vinícius H Dutra; Maiane A do Amaral; Jefferson F Loss
Journal:  J Chiropr Med       Date:  2020-09-03

4.  Can the adapted arcometer be used to assess the vertebral column in children?

Authors:  Juliana A Sedrez; Cláudia T Candotti; Fernanda S Medeiros; Mariana T Marques; Maria I Z Rosa; Jefferson F Loss
Journal:  Braz J Phys Ther       Date:  2014-10-31       Impact factor: 3.377

5.  Normative 3D opto-electronic stereo-photogrammetric posture and spine morphology data in young healthy adult population.

Authors:  Moreno D'Amico; Edyta Kinel; Piero Roncoletta
Journal:  PLoS One       Date:  2017-06-22       Impact factor: 3.240

6.  Normative 3D opto-electronic stereo-photogrammetric sagittal alignment parameters in a young healthy adult population.

Authors:  Edyta Kinel; Moreno D'Amico; Piero Roncoletta
Journal:  PLoS One       Date:  2018-09-07       Impact factor: 3.240

7.  A Visual Scan Analysis Protocol for Postural Assessment at School in Young Students.

Authors:  Maria E Alves; Daniel A Marinho; Duarte N Carneiro; Jorge Alves; Pedro Forte; Alan M Nevill; Jorge E Morais
Journal:  Int J Environ Res Public Health       Date:  2020-04-23       Impact factor: 3.390

Review 8.  Can We Quantify Aging-Associated Postural Changes Using Photogrammetry? A Systematic Review.

Authors:  Omer Dilian; Ron Kimmel; Roy Tezmah-Shahar; Maayan Agmon
Journal:  Sensors (Basel)       Date:  2022-09-02       Impact factor: 3.847

9.  Monitoring the prevalence of postural changes in schoolchildren.

Authors:  Bruna Nichele da Rosa; Matias Noll; Juliana Adami Sedrez; Tassia Silveira Furlanetto; Claudia Tarrago Candotti
Journal:  J Phys Ther Sci       Date:  2016-02-29
  9 in total