Literature DB >> 25589158

Microleakage of bacteria in different implant-abutment assemblies: an in vitro study.

Simonetta D'Ercole1, Domenico Tripodi1, Giuseppe Marzo2, Sara Bernardi2, Maria Adelaide Continenza2, Adriano Piattelli1, Flavia Iaculli1, Stefano Mummolo2.   

Abstract

PURPOSE: The aim of the present in vitro study was to evaluate the leakage observed for 2 different microbial species at the level of the implant-abutment (I-A) interface, and the marginal fit and size of microgap at the I-A interface in 2 different implant connections.
METHODS: Ten specimens of each group were tested. The inner parts of 5 implants per group were inoculated with 0.1 μL of a viable Enterococcus faecalis suspension and 5 implants per group with Aggregatibacter actinomycetemcomitans. All of the vials containing the control specimens were incubated at 37°C under aerobic condition for E. faecalis and 37°C in presence of 5% CO2 for A. actinomycetemcomitans. They were maintained for 14 days, and the possible penetration of bacterial suspension into the surrounding solution was determined by the observation of turbidity of the broth. The I-A interface was evaluated for size of microgap and measured under SEM. Five implants of each group were evaluated. The marginal fit between implant and abutment was measured at 8 random locations in each assembly, under different magnifications at the interface.
RESULTS: No leakages through the I-A interface were demonstrated for either type of connection evaluated. The microgap values of all I-A interfaces ranged from 0.008 to 2.009 μm; the differences between the 2 systems were statistically significant.
CONCLUSIONS: The present study demonstrated that a good marginal fit of implant components seemed to be able to prevent bacterial leakage.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25589158     DOI: 10.5301/jabfm.5000214

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  14 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  "All on short" prosthetic-implant supported rehabilitations.

Authors:  G Falisi; S Bernardi; C Rastelli; D Pietropaoli; F DE Angelis; M Frascaria; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

3.  In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection.

Authors:  Hooman Khorshidi; Saeed Raoofi; Afagh Moattari; Atoosa Bagheri; Mohammad Hassan Kalantari
Journal:  Int J Biomater       Date:  2016-05-03

Review 4.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

5.  Mancozeb impairs the ultrastructure of mouse granulosa cells in a dose-dependent manner.

Authors:  Maria Grazia Palmerini; Manuel Belli; Stefania Annarita Nottola; Selenia Miglietta; Serena Bianchi; Sara Bernardi; Sevastiani Antonouli; Sandra Cecconi; Giuseppe Familiari; Guido Macchiarelli
Journal:  J Reprod Dev       Date:  2017-12-11       Impact factor: 2.214

6.  The biocompatibility and mechanical properties of plasma sprayed zirconia coated abutment.

Authors:  Zhengfei Huang; Zhifeng Wang; Kaifeng Yin; Chuanhua Li; Meihua Guo; Jing Lan
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

7.  Microbiological and SEM-EDS Evaluation of Titanium Surfaces Exposed to Periodontal Gel: In Vitro Study.

Authors:  Sara Bernardi; Serena Bianchi; Anna Rita Tomei; Maria Adelaide Continenza; Guido Macchiarelli
Journal:  Materials (Basel)       Date:  2019-05-04       Impact factor: 3.623

8.  Immunohistochemical Results of Soft tissues Around a New Implant Healing-Abutment Surface: A Human Study.

Authors:  Barbara Ghinassi; Gianmaria D'Addazio; Angela Di Baldassarre; Beatrice Femminella; Giorgio Di Vincenzo; Maurizio Piattelli; Giulia Gaggi; Bruna Sinjari
Journal:  J Clin Med       Date:  2020-04-02       Impact factor: 4.241

9.  Commercial oral hygiene products and implant collar surfaces: Scanning electron microscopy observations.

Authors:  Serena Bianchi; Giulia Fantozzi; Sara Bernardi; Sevastiani Antonouli; Maria Adelaide Continenza; Guido Macchiarelli
Journal:  Can J Dent Hyg       Date:  2020-02-01

10.  Influence of Implant Neck Design on Peri-Implant Tissue Dimensions: A Comparative Study in Dogs.

Authors:  José Luis Calvo-Guirado; Raúl Jiménez-Soto; Carlos Pérez Albacete-Martínez; Manuel Fernández-Domínguez; Sérgio Alexandre Gehrke; José Eduardo Maté-Sánchez de Val
Journal:  Materials (Basel)       Date:  2018-10-17       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.