| Literature DB >> 25578057 |
Sun Hyun Bae1, Mi-Sook Kim2, Won Il Jang2, Chul-Seung Kay3, Woochul Kim4, Eun Seog Kim5, Jin Ho Kim6, Jin Hee Kim7, Kwang Mo Yang8, Kyu Chan Lee9, A Ram Chang10, Sunmi Jo11.
Abstract
PURPOSE: The purpose of this study is to investigate the current status of stereotactic body radiotherapy (SBRT) in Korea. A nationwide survey was conducted by the Korean Stereotactic Radiosurgery Group of the Korean Society for Radiation Oncology (KROG 13-13).Entities:
Keywords: Radiation oncology; Radiosurgery; Survey
Year: 2014 PMID: 25578057 PMCID: PMC4506107 DOI: 10.4143/crt.2014.021
Source DB: PubMed Journal: Cancer Res Treat ISSN: 1598-2998 Impact factor: 4.679
Fig. 1.(A) Cumulative adoption of stereotactic body radiotherapy (SBRT) after its introduction in 1997; green bar indicates institutions which have already been prepared to start SBRT in 2013. (B) The number of SBRT cases per year in each institution using SBRT as of June 2013.
Fig. 2.(A) Treatment sites applied stereotactic body radiotherapy (SBRT). (B) Cumulative adoption of SBRT for the two most common treatment sites (lung and liver).
Fig. 3.The prescribed doses for non-small cell lung cancer (A), lung metastases (B), hepatocellular carcinoma (C), and liver metastases (D) among institutions. SBRT, stereotactic body radiotherapy.
Details of the methods used for control of moving organs
| No. of institutions (%) (n=38) | ||
|---|---|---|
| Method of immobilization | ||
| Alpha cradle/vacuum-lock | 16 (42) | |
| Stereotactic body frame | 10 (26) | |
| Wingboard | 10 (26) | |
| Alpha cradle/vacuum-lock+wingboard | 10 (26) | |
| Stereotactic body frame+alpha cradle/vacuum-lock+wingboard | 6 (16) | |
| Stereotactic body frame+alpha cradle/vacuum-lock | 2 (5) | |
| No use | 3 (8) | |
| Method of respiratory motion control | ||
| Respiratory gating methods | Varian RPM | 24 (63) |
| ExacTrac gating-Novalis gating | 4 (11) | |
| Anzai gating | 2 (5) | |
| Forced shallow breathing with abdominal compression | 13 (34) | |
| Real-time tumor tracking methods | 6 (16) | |
| Breath-hold methods | Active-breathing control | 2 (5) |
| Deep-inspiration breath hold | 0 | |
| Self-held breathing hold with respiratory monitoring | 2 (5) | |
| Self-held breathing hold without respiratory monitoring | 0 | |
| No use | 6 (16) | |
To identify all equipment per institution, the respondents selected multiple answers. RPM, Real-Time Position Management.
Types of treatment machines for stereotactic body radiotherapy in Korea
| Types of treatment machines | No. of institutions (%) (n=38) |
|---|---|
| RapidArc | 16 (42) |
| Varian Clinac iX | 10 (26) |
| CyberKnife | 8 (21) |
| Novalis | 4 (11) |
| Tomotherapy | 4 (11) |
| Novalis Tx | 3 (8) |
| Elekta VMAT | 3 (8) |
| TrueBeam | 3 (8) |
| Simens Oncor | 1 (3) |
| Simense Artiste | 1 (3) |
| Varian Clinac 2100C | 1 (3) |
To identify all equipment per institution, the respondents selected multiple answers.
Fig. 4.Application rate of respiratory gating method to moving targets according to institution. SBRT, stereotactic body radiotherapy.