Literature DB >> 25576504

Advanced digital subtraction angiography and MR fusion imaging protocol applied to accurate placement of flow diverter device.

Giuseppe Faragò1, Valentina Caldiera1, Giovanni Tempra1, Elisa Ciceri1.   

Abstract

In recent years there has been a progressive increase in interventional neuroradiology procedures, partially due to improvements in devices, but also to the simultaneous development of technologies and radiological images. Cone beam CT (Dyna-CT; Siemens) is a method recently used to obtain pseudo CT images from digital subtraction angiography (DSA) with a flat panel detector. Using dedicated software, it is then possible to merge Dyna-CT images with images from a different source. We report here the usefulness of advanced DSA techniques (Syngo-Dyna CT, three-dimensional DSA iPilot) for the treatment of an intracranial aneurysm with a flow diverter device. Merging MR and Dyna-CT images at the end of the procedure proved to be a simple and rapid additional method of verifying the success of the intervention. 2015 BMJ Publishing Group Ltd.

Entities:  

Keywords:  Aneurysm; Angiography; Flow Diverter; Intervention; Magnetic Resonance Angiography

Mesh:

Year:  2015        PMID: 25576504      PMCID: PMC4289783          DOI: 10.1136/bcr-2014-011428

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  9 in total

1.  Provocative test occlusion or the Matas test: who was Rudolph Matas?

Authors:  Huan Wang; Giuseppe Lanzino; Robert R Kraus; Kenneth W Fraser
Journal:  J Neurosurg       Date:  2003-04       Impact factor: 5.115

2.  Evaluation of cerebral arteriovenous malformation using 'dual vessel fusion' technology.

Authors:  Liuqing Sheng; Jun Li; Huanhuan Li; Guodong Li; Gang Chen; Weichu Xiang; Qiang Wang; Zhiqiang Gan; Qi Sun; Bing Yan; Janina Beilner; Lian-Ting Ma
Journal:  J Neurointerv Surg       Date:  2013-11-14       Impact factor: 5.836

3.  DynaCT imaging for intraprocedural evaluation of flow-diverting stent apposition during endovascular treatment of intracranial aneurysms.

Authors:  Dale Ding; Robert M Starke; Christopher R Durst; John R Gaughen; Avery J Evans; Mary E Jensen; Kenneth C Liu
Journal:  J Clin Neurosci       Date:  2014-05-20       Impact factor: 1.961

Review 4.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

5.  3D Road-Mapping in the Endovascular Treatment of Cerebral Aneurysms and Arteriovenous Malformations.

Authors:  S Rossitti; M Pfister
Journal:  Interv Neuroradiol       Date:  2009-11-04       Impact factor: 1.610

6.  The utility of DynaCT in neuroendovascular procedures.

Authors:  N S Heran; J K Song; K Namba; W Smith; Y Niimi; A Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

7.  Effects of changing physiologic conditions on the in vivo quantification of hemodynamic variables in cerebral aneurysms treated with flow diverting devices.

Authors:  Fernando Mut; Danny Ruijters; Drazenko Babic; Carlos Bleise; Pedro Lylyk; Juan R Cebral
Journal:  Int J Numer Method Biomed Eng       Date:  2013-08-30       Impact factor: 2.747

8.  Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications--a retrospective data analysis.

Authors:  Francesco Briganti; Manuela Napoli; Fabio Tortora; Domenico Solari; Mauro Bergui; Edoardo Boccardi; Enrico Cagliari; Lucio Castellan; Francesco Causin; Elisa Ciceri; Luigi Cirillo; Roberto De Blasi; Luigi Delehaye; Francesco Di Paola; Andrea Fontana; Roberto Gasparotti; Giulio Guidetti; Ignazio Divenuto; Giuseppe Iannucci; Maurizio Isalberti; Marco Leonardi; Fernando Lupo; Salvatore Mangiafico; Andrea Manto; Roberto Menozzi; Mario Muto; Nunzio Paolo Nuzzi; Rosario Papa; Benedetto Petralia; Mariangela Piano; Maurizio Resta; Riccardo Padolecchia; Andrea Saletti; Giovanni Sirabella; Luca Piero Valvassori Bolgè
Journal:  Neuroradiology       Date:  2012-05-09       Impact factor: 2.804

Review 9.  Flow diverters for intracranial aneurysms.

Authors:  Yazan J Alderazi; Darshan Shastri; Tareq Kass-Hout; Charles J Prestigiacomo; Chirag D Gandhi
Journal:  Stroke Res Treat       Date:  2014-05-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.