Automatic detection of coronary artery anastomoses in epicardial ultrasound images.

Alex Skovsbo Jørgensen1, Samuel Emil Schmidt, Niels-Henrik Staalsen, Lasse Riis Østergaard.   

Abstract

PURPOSE: Epicardial ultrasound (EUS) can be used to assess the quality of coronary artery bypass graft surgery (CABG) anastomoses by determining stenotic rates. Currently, no objective quantitative methods are available for the analysis of EUS images. Therefore, surgeons have to be trained in interpreting EUS images, which may limit the use of EUS in clinical practice. Automatic detection of vessel structures can enable the objective and quantitative quality assessment of anastomoses without user interaction to facilitate the revision of anastomoses during the primary surgery.
METHODS: An automatic vessel detection algorithm extracted and detected image regions that uniquely intersected with the vessel lumen of anastomotic structures. First, an initial pixel-based segmentation was performed from regional minimums using a watershed segmentation and an adaptive thresholding approach. A region-based merging step was then performed to merge oversegmented vessel structures using a Bayesian classification of different region combinations constructed from the pixel-based segmentations. Finally, a vessel classification step was performed on the extracted regions after the region-based merging to determine the probabilities that the regions contained vessel structures.
RESULTS: The performance of the vessel classifier was tested using m-fold cross-validation of 320 EUS images containing anastomotic vessel structures from 16 anastomoses made on healthy porcine vessels. An area under the curve of 0.966 (95 % CI 0.951-0.984) and 0.989 (95 % CI 0.985-0.993, p < 0.001) of a precision-recall and receiver operator characteristic curve, respectively, was obtained when detecting vessel regions extracted from the EUS images.
CONCLUSIONS: The vessel detection algorithm can detect vessel regions in EUS images at a high accuracy. It can be used to enable the automatic analysis of EUS images for the quality assessment of CABG anastomoses.

Mesh:

Year:  2015        PMID: 25572703     DOI: 10.1007/s11548-014-1144-3

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  13 in total

1.  Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

Authors:  Rune Haaverstad; Nicola Vitale; Ole Tjomsland; Arve Tromsdal; Hans Torp; Stein O Samstad
Journal:  Ann Thorac Surg       Date:  2002-10       Impact factor: 4.330

2.  Intraoperative color Doppler ultrasound assessment of anastomoses of the left internal mammary artery to the left anterior descending coronary artery during off-pump coronary artery bypass surgery correlates with angiographic evaluation at the 8-month follow-up.

Authors:  Ole Tjomsland; Rune Wiseth; Alexander Wahba; Arve Tromsdal; Stein O Samstad; Rune Haaverstad
Journal:  Heart Surg Forum       Date:  2003       Impact factor: 0.676

3.  A new technique facilitating intraoperative, high-frequency echocardiography of coronary bypass graft anastomoses.

Authors:  Niels-Henrik Staalsen; Benedict Kjaergaard; Jan Jesper Andreasen
Journal:  J Thorac Cardiovasc Surg       Date:  2011-01       Impact factor: 5.209

4.  Detection of construction errors in ex vivo coronary artery anastomoses by 13-MHz epicardial ultrasonography.

Authors:  Ricardo P J Budde; Rudy Meijer; Thomas C Dessing; Cornelius Borst; Paul F Gründeman
Journal:  J Thorac Cardiovasc Surg       Date:  2005-05       Impact factor: 5.209

5.  Epicardial ultrasonography: a potential method for intraoperative quality assessment of coronary bypass anastomoses?

Authors:  Per Kristian Hol; Kai Andersen; Helge Skulstad; Per Steinar Halvorsen; Per Snorre Lingaas; Rune Andersen; Jacob Bergsland; Erik Fosse
Journal:  Ann Thorac Surg       Date:  2007-09       Impact factor: 4.330

6.  Automated detection of the carotid artery wall in B-mode ultrasound images using active contours initialized by the Hough Transform.

Authors:  J Stoitsis; S Golemati; S Kendros; K S Nikita
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

7.  Integration of local and global features for anatomical object detection in ultrasound.

Authors:  Bahbibi Rahmatullah; Aris T Papageorghiou; J Alison Noble
Journal:  Med Image Comput Comput Assist Interv       Date:  2012

8.  Results of graft patency by immediate angiography in minimally invasive coronary artery surgery.

Authors:  M J Mack; J A Magovern; T A Acuff; R J Landreneau; D M Tennison; E J Tinnerman; J A Osborne
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

Review 9.  Intraoperative coronary graft assessment.

Authors:  Michael J Mack
Journal:  Curr Opin Cardiol       Date:  2008-11       Impact factor: 2.161

10.  Tumor detection in automated breast ultrasound images using quantitative tissue clustering.

Authors:  Woo Kyung Moon; Chung-Ming Lo; Rong-Tai Chen; Yi-Wei Shen; Jung Min Chang; Chiun-Sheng Huang; Jeon-Hor Chen; Wei-Wen Hsu; Ruey-Feng Chang
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

View more