Literature DB >> 12400823

Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

Rune Haaverstad1, Nicola Vitale, Ole Tjomsland, Arve Tromsdal, Hans Torp, Stein O Samstad.   

Abstract

BACKGROUND: Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery (LIMA) to left anterior descending coronary artery (LAD) anastomoses performed on the beating heart.
METHODS: Twenty-four LIMA-to-LAD anastomoses were evaluated with real-time epicardial ultrasound imaging using an ultrasound transducer positioned between the paddles of the stabilizer during off-pump procedures. The length of the anastomosis (D(A)), diameters of LIMA (D(M)), LAD at the toe of the anastomosis (D1), and 5 mm distally to the anastomosis (D2) were measured, and the ratios between these variables were calculated. The flow velocity through the anastomoses was visualized by color Doppler coding, and flow was assessed with transit-time flowmetry.
RESULTS: The epicardial color Doppler ultrasound allowed accurate assessment of the anastomoses. Twenty-three (96%) of the primary anastomoses were confirmed as patent. Mean ratios of D1/D2, D(A)/D2, and D(M)/D2 were 0.89 +/- 0.13, 3.01 +/- 1.04 and 1.32 +/- 0.32, respectively. One anastomosis had a stenosis more than 50% detected by color Doppler ultrasound. After surgical revision, transit-time flow increased from 22 to 40 ml/min.
CONCLUSIONS: Intraoperative color Doppler ultrasound allowed adequate imaging for quality assessment of LIMA-to-LAD anastomoses performed on the beating heart. One anastomosis was revised due to a technical error detected by epicardial color Doppler imaging. Epicardial ultrasound scanning is a valuable tool for intraoperative assessment of LIMA-to-LAD anastomoses during off-pump coronary surgery.

Mesh:

Year:  2002        PMID: 12400823     DOI: 10.1016/s0003-4975(02)04058-4

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

Review 1.  High-frequency epicardial ultrasound: review of a multipurpose intraoperative tool for coronary surgery.

Authors:  Ricardo P J Budde; Patricia F A Bakker; Paul F Gründeman; Cornelius Borst
Journal:  Surg Endosc       Date:  2008-09-20       Impact factor: 4.584

2.  Automatic detection of coronary artery anastomoses in epicardial ultrasound images.

Authors:  Alex Skovsbo Jørgensen; Samuel Emil Schmidt; Niels-Henrik Staalsen; Lasse Riis Østergaard
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-01-09       Impact factor: 2.924

3.  The use of intraoperative graft assessment in guiding graft revision.

Authors:  Teresa M Kieser; David P Taggart
Journal:  Ann Cardiothorac Surg       Date:  2018-09

Review 4.  Localizing intramyocardially embedded left anterior descending artery during coronary bypass surgery: literature review.

Authors:  Edem Ziadinov; Hilal Al-Sabti
Journal:  J Cardiothorac Surg       Date:  2013-10-30       Impact factor: 1.637

5.  Evaluation of a novel laser-assisted coronary anastomotic connector - the Trinity Clip - in a porcine off-pump bypass model.

Authors:  David Stecher; Glenn Bronkers; Jappe O T Noest; Cornelis A F Tulleken; Imo E Hoefer; Lex A van Herwerden; Gerard Pasterkamp; Marc P Buijsrogge
Journal:  J Vis Exp       Date:  2014-11-24       Impact factor: 1.355

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.