| Literature DB >> 25566708 |
Ashwini Thimmarayappa, Nivash Chandrasekaran1, A M Jagadeesh, Shreedhar S Joshi.
Abstract
AIMS: The aim of the study was to measure airway patency objectively during dexmedetomidine sedation under radiographic guidance in spontaneously breathing pediatric patients scheduled for cardiac catheterization procedures. SUBJECTS AND METHODS: Thirty-five patients in the age group 5-10 years scheduled for cardiac catheterization procedures were enrolled. All study patients were given loading dose of dexmedetomidine at 1 mg/kg/min for 10 min and then maintenance dose of 1.5 mg/kg/h. Radiographic airway patency was assessed at the start of infusion (0 min) and after 30 min. Antero-posterior (AP) diameters were measured manually at the nasopharyngeal and retroglossal levels. Dynamic change in airway between inspiration and expiration was considered a measure of airway collapsibility. Patients were monitored for hemodynamics, recovery time and complications. STATISTICAL ANALYSIS: Student paired t-test was used for data analysis. P < 0.05 was considered significant.Entities:
Mesh:
Substances:
Year: 2015 PMID: 25566708 PMCID: PMC4900326 DOI: 10.4103/0971-9784.148318
Source DB: PubMed Journal: Ann Card Anaesth ISSN: 0971-9784
Figure 1Lateral view of Airway to demonstrate measurement of AP diameter at nasopharyngeal and retroglossal level
Comparison of Hemodynamics, Saturation and Airway diameter at 0 and 30 minutes
| Dimension | Mean±SD | 95% CI | ||
|---|---|---|---|---|
| 0 min | 30 min | |||
| HR (beats/min) | 119.94±13.22 | 102.17±12.64 | −23.94 to −11.60 | 0.0001 |
| SBP (mmHg) | 116.49±6.73 | 114.29±6.74 | −5.41 to 1.01 | 0.18 |
| DBP (mmHg) | 62.37±6.91 | 60.26±5.66 | −5.13 to 0.899 | 0.17 |
| Oxygen saturation (%) | 99.7±0.63 | 99.66±0.64 | −0.33 to 0.27 | 0.84 |
| Retroglossal | ||||
| AP diameter (mm) | ||||
| Minimum | 6.98±1.097 | 5.27±1.15 | −1.97 to −1.46 | 0.0001 |
| Maximum | 7.49±1.22 | 6.92±1.12 | −0.86 to −0.28 | 0.0003 |
| Collapsibility | 0.502±0.72 | 1.64±0.57 | 0.89 to 1.39 | 0.0001 |
| Nasopharyngeal | ||||
| AP diameter (mm) | ||||
| Minimum | 6.27±1.09 | 4.26±1.03 | −2.22 to −1.81 | 0.0001 |
| Maximum | 6.51±1.14 | 5.99±1.03 | −0.66 to −0.36 | 0.0001 |
| Collapsibility | 0.23±0.33 | 1.74±0.70 | 1.27 to 1.74 | 0.0001 |
HR: Heart rate, SBP: Systolic blood pressure, DBP: Diastolic blood pressure, SD: Standard deviation, CI: Confidence interval, AP: Anteroposterior
Figure 2Haemodynamics parameters. HR: Heart rate, SBP: Systolic blood pressure, DBP: Diastolic blood pressure, S: Saturation
Figure 3Mean airway diameter at nasopharyngeal level
Figure 4Mean airway diameter at retroglossal level