Literature DB >> 25550014

Ceramic-on-ceramic total hip arthroplasty in patients younger than 55 years.

Roshan P Shah1, John A Scolaro2, Roger Componovo3, Jonathan P Garino4, Gwo-Chin Lee1.   

Abstract

PURPOSE: To review the outcomes of 65 patients younger than 55 years who underwent uncemented total hip arthroplasty (THA) using third-generation ceramic-on-ceramic prostheses.
METHODS: Medical records of 30 men and 35 women (80 hips) aged 18 to 55 (mean, 39) years who underwent uncemented THA using third-generation ceramic-onceramic prostheses by a single surgeon were reviewed. 61 THAs used the Reflection cup with the Synergy stem (n=49), Spectron stem (n=7), or Anthology stem (n=5), and 19 THAs used the Trident cup with the Secur-Fit stem. Outcomes were assessed based on the UCLA Activity Score and Harris Hip Score, as well as radiolucency around the implants, malposition, and subsidence on radiographs. Patients were asked about their satisfaction with current activity level (yes/no), activity limitation (no limitation, musculoskeletal limitation, psychological impediments and lack of motivation, and pain or disability of the operative hip), and change in occupational activity level (same or similar, more active, and less active or disability).
RESULTS: The mean follow-up period was 54 (range, 24-110) months. Six patients were excluded from the analysis owing to prosthetic failure secondary to ceramic liner fracture after falling (n=2), acetabular component loosening (n=1), intolerable squeak (n=1), periprosthetic fracture (n=1), and instability (n=1). The mean UCLA Activity Score improved from 4.0 (range, 1-10) to 7.7 (range, 2-10) [p<0.001], and the mean Harris Hip Score improved from 52.8 (range, 25-69) to 91.0 (range, 38-100) [p<0.001]. No hip had evidence of subsidence, loosening, or osteolysis. 52 (80%) patients were satisfied with their activity level; 28 (43%) patients reported no activity limitation; and 57 (88%) patients kept the same or similar occupation.
CONCLUSION: Ceramic-on-ceramic THA achieved acceptable clinical and radiographic outcomes.

Entities:  

Keywords:  arthroplasty, replacement, hip; ceramics

Mesh:

Substances:

Year:  2014        PMID: 25550014     DOI: 10.1177/230949901402200314

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  4 in total

1.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

2.  Return to sports and work after partial shoulder replacement surgery.

Authors:  M Bülhoff; B Sowa; T Bruckner; F Zeifang; P Rais
Journal:  Orthopade       Date:  2017-08       Impact factor: 1.087

3.  Surgeons' Awareness and Impaction Technique of a Ceramic Liner into a Metal Shell.

Authors:  Hong Seok Kim; Jung-Wee Park; Young-Kyun Lee; Alessandro Alan Porporati; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  Clin Orthop Surg       Date:  2022-05-13

4.  Getting back in the game after humeral head resurfacing.

Authors:  Matthias Bülhoff; Boris Sowa; Thomas Bruckner; Patric Raiss; Felix Zeifang
Journal:  J Orthop       Date:  2018-01-31
  4 in total