Literature DB >> 25542947

Differentiation of benign and malignant sub-1-cm breast lesions using contrast-enhanced sonography.

He Liu1, Yuxin Jiang2, Qing Dai1, Qingli Zhu1, Liang Wang1, Jing Zhang1, Qian Yang1.   

Abstract

OBJECTIVES: The purpose of this study was to prospectively assess the diagnostic efficacy of contrast-enhanced sonography for differential diagnosis of sub-1-cm breast lesions.
METHODS: Contrast-enhanced sonography was performed in 46 women with 46 sub-1-cm breast lesions scheduled for surgery or biopsy. Histologic results were used as a reference standard. The contrast enhancement pattern, enhancement degree, direction, margin, radial vessels surrounding the lesion, and lesion size discrepancy between contrast-enhanced and conventional sonography were evaluated.
RESULTS: The detection rates for increased size, radial vessels surrounding the lesion, and hyperenhancement on contrast-enhanced sonography were significantly higher in the malignant than the benign group (P < .05). The sensitivity, specificity, and accuracy for increased size were 72.7%, 80.0%, and 78.2%, respectively. The sensitivity, specificity, and accuracy for radial vessels surrounding the lesion were 54.5%, 97.1%, and 87.0%. The sensitivity, specificity, and accuracy for hyperenhancement were 81.8%, 60.0%, and 65.0%. No significant difference was found for the enhancement pattern, direction, and margin between the groups.
CONCLUSIONS: Contrast-enhanced sonographic features of sub-1-cm breast lesions included increased size on contrast-enhanced sonography, radial vessels surrounding the lesion, and hyperenhancement. Identification of these features is useful for differentiation of small breast lesions.
© 2015 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  breast cancer; breast ultrasound; contrast-enhanced sonography; differential diagnosis; small lesions

Mesh:

Substances:

Year:  2015        PMID: 25542947     DOI: 10.7863/ultra.34.1.117

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  2 in total

1.  Diagnosis of sub-centimetre breast lesions: combining BI-RADS-US with strain elastography and contrast-enhanced ultrasound-a preliminary study in China.

Authors:  Xiaoyun Xiao; Qiongchao Jiang; Huan Wu; Xiaofeng Guan; Wei Qin; Baoming Luo
Journal:  Eur Radiol       Date:  2016-10-19       Impact factor: 5.315

2.  Value of contrast-enhanced ultrasound area ratio in identifying benign and malignant small breast masses.

Authors:  Wei Wang; Yan Zheng; Xiao-Feng Wu; Dan Zhao; Li-Zhu Hou; Fei Shi; Jin-Jin Liu; Feng-Lin Dong
Journal:  Gland Surg       Date:  2020-10
  2 in total