Literature DB >> 25539007

Differences in degradation behavior of two non-cross-linked collagen barrier membranes: an in vitro and in vivo study.

Ahmet Bozkurt, Christian Apel, Bernd Sellhaus, Sabien van Neerven, Bastian Wessing, Ralf-Dieter Hilgers, Norbert Pallua.   

Abstract

OBJECTIVES: Collagen barrier membranes are used in guided bone regeneration/guided tissue regeneration because of their excellent bio- and cytocompatibility. However, they are considered to have limitations in clinical outcome because of rapid and unpredictable degradation profiles. The aim of this study was to investigate the degradation behavior of two porcine-based, non-cross-linked collagen membranes in vitro and in vivo.
MATERIALS AND METHODS: Remaix™ (RX; Matricel GmbH, Herzogenrath, Germany) and Bio-Gide® (BG; Geistlich Pharma AG, Wolhusen, Switzerland) membranes were characterized by testing mechanical strength, denaturation temperature, enzymatic degradation and hydroxyproline content in vitro (n = 5 up to 16). Thereafter, both membranes were implanted subcutaneously in rats (n = 20) for up to 20 weeks to investigate tissue compatibility with respect to membrane thickness.
RESULTS: BG contained a significant higher hydroxyproline content compared with RX, but RX showed a higher stress at break (dry: 11.4 (SD 2.9) vs. 5.5 (SD 1.5) N/mm(2)), higher suture retention (wet: 5.6 (SD 1.3) vs. 2.7 (SD 0.7) N), increased denaturation temperature (55.1 (SD 1) vs. 49.4 (SD 0.6)°C) and an almost twofold reduction in degradation rate (15.6% (SEM 1.3)/h vs. 24.8% (SEM 2.9)/h) in vitro. In the rat model, both membranes showed excellent tissue compatibility without signs of inflammatory reactions. Shortly after implantation, RX and BG showed moderate infiltration of mononuclear cells that appeared not to be influenced by the surface texture of the membranes. In the histomorphometric analysis, both membranes showed significant different thickness over the 20 weeks period (P = 0.0002). Although the thickness remained almost stable during the first 9 weeks after implantation, after 20 weeks, the thickness of RX decreased only slightly, whereas BG showed a thickness loss of around 50% and stronger degradation than RX. Therefore, the higher stability of RX against biodegradation found in vitro was confirmed in the animal study.
CONCLUSION: This study shows differences in the biodegradation characteristics of two non-cross-linked collagen membranes in vitro and in vivo. Whether the higher stability of RX is of clinical relevance should be analyzed in future clinical investigations.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25539007     DOI: 10.1111/clr.12284

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

1.  The Condensation of Collagen Leads to an Extended Standing Time and a Decreased Pro-inflammatory Tissue Response to a Newly Developed Pericardium-based Barrier Membrane for Guided Bone Regeneration.

Authors:  Tristan Gueldenpfennig; Alireza Houshmand; Ole Jung; Mike Barbeck; Stevo Najman; Sanja Stojanovic; Tadas Korzinskas; Ralf Smeets; Martin Gosau; Jens Pissarek; Steffen Emmert
Journal:  In Vivo       Date:  2020 May-Jun       Impact factor: 2.155

2.  Suitability of the use of an elastin matrix combined with bone morphogenetic protein for the repair of cranial defects.

Authors:  Renato de Moraes; Ana Maria de Guzzi Plepis; Virginia da Conceição Amaro Martins; Marco Antonio Hungaro Duarte; Murilo Priori Alcalde; Rogerio Leone Buchaim; Karina Torres Pomini; Eduardo Gomes Machado; Marcelo de Azevedo E Sousa Munhoz; Fernando Bento Cunha; Amanda Regina Alves Calegari; Amilton Iatecola; Samantha Ketelyn Silva; Marcelo Rodrigues da Cunha
Journal:  Am J Transl Res       Date:  2019-08-15       Impact factor: 4.060

3.  [Biodegradation properties of multi-laminated small intestinal submucosa].

Authors:  W Y Wu; B W Li; Y H Liu; X Z Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-06-18

Review 4.  Advances in Barrier Membranes for Guided Bone Regeneration Techniques.

Authors:  Ze Yang; Chang Wu; Huixin Shi; Xinyu Luo; Hui Sun; Qiang Wang; Dan Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-06-22

5.  A multicenter randomized controlled clinical trial using a new resorbable non-cross-linked collagen membrane for guided bone regeneration at dehisced single implant sites: interim results of a bone augmentation procedure.

Authors:  Bastian Wessing; Istvan Urban; Eduardo Montero; Werner Zechner; Markus Hof; Javier Alández Chamorro; Nuria Alández Martin; Giovanni Polizzi; Silvio Meloni; Mariano Sanz
Journal:  Clin Oral Implants Res       Date:  2016-12-18       Impact factor: 5.977

6.  Characterization of Five Collagenous Biomaterials by SEM Observations, TG-DTA, Collagenase Dissolution Tests and Subcutaneous Implantation Tests.

Authors:  Miki Hoshi; Tomofumi Sawada; Wataru Hatakeyama; Masayuki Taira; Yuki Hachinohe; Kyoko Takafuji; Hidemichi Kihara; Shinji Takemoto; Hisatomo Kondo
Journal:  Materials (Basel)       Date:  2022-02-02       Impact factor: 3.623

7.  Ultrastructural and Physicochemical Characterization of a Non-Crosslinked Type 1 Bovine Derived Collagen Membrane.

Authors:  Igor da Silva Brum; Carlos Nelson Elias; Ana Lucia Rosa Nascimento; Cherley Borba Vieira de Andrade; Ronaldo Sergio de Biasi; Jorge José de Carvalho
Journal:  Polymers (Basel)       Date:  2021-11-26       Impact factor: 4.329

8.  In Vitro Evaluation of the Permeability of Different Resorbable Xenogeneic Membranes after Collagenolytic Degradation.

Authors:  Ramona Kölliker; Stefan P Hicklin; Constanze Hirsiger; Chun Ching Liu; Fredi Janett; Patrick R Schmidlin
Journal:  Membranes (Basel)       Date:  2022-08-17

9.  Synthesis and Characterization of Polycaprolactone-Based Polyurethanes for the Fabrication of Elastic Guided Bone Regeneration Membrane.

Authors:  Shyh-Yuan Lee; Sheng-Chien Wu; Hsuan Chen; Lo-Lin Tsai; Jy-Jiunn Tzeng; Chih-Hsin Lin; Yuan-Min Lin
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

10.  Tensile Properties of Three Selected Collagen Membranes.

Authors:  Perry Raz; Tamar Brosh; Guy Ronen; Haim Tal
Journal:  Biomed Res Int       Date:  2019-12-05       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.