Literature DB >> 25538803

An enzyme-linked immunosorbent assay on a centrifugal platform using magnetic beads.

Chih-Hsin Shih1, Ho-Chin Wu1, Chong-Yi Chang1, Wen-Hong Huang1, Yi-Feng Yang2.   

Abstract

An automated, disk-based, enzyme-linked immunosorbent assay (ELISA) system is presented in this work. Magnetic beads were used as the antibody carriers to improve the assay sensitivity and shorten the reaction time. The magnetic module integrated on the system is capable of controlling the magnetic beads to either move in the incubation stage or immobilize at a specific location during washing stage. This controlling mechanism utilizes a passive controlling approach so that it can be performed through disk spinning without the need of active control from external devices. The movement of the magnetic beads was investigated and the optimal rotational speed was found to be related to the ratio of the processing time to the cycle time of the magnetic beads. Comparing to ELISA conducted on microtiter plates, similar test results could be achieved by the disk-based ELISA but the entire protocol can be finished automatically within 45 min with much less reagent consumption.

Year:  2014        PMID: 25538803      PMCID: PMC4222274          DOI: 10.1063/1.4896297

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  16 in total

1.  Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood.

Authors:  Beom Seok Lee; Yang Ui Lee; Han-Sang Kim; Tae-Hyeong Kim; Jiwoon Park; Jeong-Gun Lee; Jintae Kim; Hanshin Kim; Wee Gyo Lee; Yoon-Kyoung Cho
Journal:  Lab Chip       Date:  2010-11-01       Impact factor: 6.799

2.  Batch-mode mixing on centrifugal microfluidic platforms.

Authors:  M Grumann; A Geipel; L Riegger; R Zengerle; J Ducrée
Journal:  Lab Chip       Date:  2005-04-07       Impact factor: 6.799

3.  Parallel nanoliter microfluidic analysis system.

Authors:  Per Andersson; Gerald Jesson; Gunnar Kylberg; Gunnar Ekstrand; Gunnar Thorsén
Journal:  Anal Chem       Date:  2007-05-02       Impact factor: 6.986

4.  Whole blood immunoassay based on centrifugal bead sedimentation.

Authors:  Ulrich Y Schaff; Greg J Sommer
Journal:  Clin Chem       Date:  2011-03-17       Impact factor: 8.327

5.  Magnetic bead-based reverse colorimetric immunoassay strategy for sensing biomolecules.

Authors:  Zhuangqiang Gao; Mingdi Xu; Li Hou; Guonan Chen; Dianping Tang
Journal:  Anal Chem       Date:  2013-06-27       Impact factor: 6.986

6.  Centrifugal gas-phase transition magnetophoresis (GTM)--a generic method for automation of magnetic bead based assays on the centrifugal microfluidic platform and application to DNA purification.

Authors:  Oliver Strohmeier; Alexander Emperle; Günter Roth; Daniel Mark; Roland Zengerle; Felix von Stetten
Journal:  Lab Chip       Date:  2012-11-12       Impact factor: 6.799

7.  Flow-enhanced electrochemical immunosensors on centrifugal microfluidic platforms.

Authors:  Tae-Hyeong Kim; Kameel Abi-Samra; Vijaya Sunkara; Dong-Kyu Park; Mary Amasia; Nahui Kim; Jintae Kim; Hanshin Kim; Marc Madou; Yoon-Kyoung Cho
Journal:  Lab Chip       Date:  2013-09-21       Impact factor: 6.799

8.  One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device.

Authors:  Yoon-Kyoung Cho; Jeong-Gun Lee; Jong-Myeon Park; Beom-Seok Lee; Youngsun Lee; Christopher Ko
Journal:  Lab Chip       Date:  2007-02-15       Impact factor: 6.799

9.  A rapid and highly sensitive portable chemiluminescent immunosensor of carcinoembryonic antigen based on immunomagnetic separation in human serum.

Authors:  Shuxue Qu; Juntao Liu; Jinping Luo; Yiqing Huang; Wentao Shi; Bin Wang; Xinxia Cai
Journal:  Anal Chim Acta       Date:  2013-01-09       Impact factor: 6.558

10.  A fully automated immunoassay from whole blood on a disc.

Authors:  Beom Seok Lee; Jung-Nam Lee; Jong-Myeon Park; Jeong-Gun Lee; Suhyeon Kim; Yoon-Kyoung Cho; Christopher Ko
Journal:  Lab Chip       Date:  2009-03-05       Impact factor: 6.799

View more
  5 in total

1.  Preface to Special Topic: Selected Papers from the Advances in Microfluidics and Nanofluidics 2014 Conference in Honor of Professor Hsueh-Chia Chang's 60th Birthday.

Authors:  Chia-Fu Chou; Pei-Kuen Wei; Yeng-Long Chen
Journal:  Biomicrofluidics       Date:  2014-10-28       Impact factor: 2.800

2.  Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays.

Authors:  Moonwoo La; Sang Min Park; Dong Sung Kim
Journal:  Biomicrofluidics       Date:  2015-01-13       Impact factor: 2.800

3.  Disk-based enzyme-linked immunosorbent assays using the liquid-aliquoting and siphoning-evacuation technique.

Authors:  Ho-Chin Wu; Yen-Hao Chen; Chih-Hsin Shih
Journal:  Biomicrofluidics       Date:  2018-09-13       Impact factor: 2.800

4.  Nominal effective immunoreaction volume of magnetic beads at single bead level.

Authors:  Rui Wang; Yuan Chen; Kai Fan; Feng Ji; Jian Wu; Yong-Hua Yu
Journal:  J Zhejiang Univ Sci B       Date:  2017 Oct.       Impact factor: 3.066

5.  ImmunoDisk-A Fully Automated Bead-Based Immunoassay Cartridge with All Reagents Pre-Stored.

Authors:  Benita Johannsen; Desirée Baumgartner; Lena Karkossa; Nils Paust; Michal Karpíšek; Nagihan Bostanci; Roland Zengerle; Konstantinos Mitsakakis
Journal:  Biosensors (Basel)       Date:  2022-06-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.