Literature DB >> 25537377

The effect of ergonomic laparoscopic tool handle design on performance and efficiency.

Kryztopher D Tung1, Rami M Shorti, Earl C Downey, Donald S Bloswick, Andrew S Merryweather.   

Abstract

BACKGROUND: Many factors can affect a surgeon's performance in the operating room; these may include surgeon comfort, ergonomics of tool handle design, and fatigue. A laparoscopic tool handle designed with ergonomic considerations (pistol grip) was tested against a current market tool with a traditional pinch grip handle. The goal of this study is to quantify the impact ergonomic design considerations which have on surgeon performance. We hypothesized that there will be measurable differences between the efficiency while performing FLS surgical trainer tasks when using both tool handle designs in three categories: time to completion, technical skill, and subjective user ratings.
METHODS: The pistol grip incorporates an ergonomic interface intended to reduce contact stress points on the hand and fingers, promote a more neutral operating wrist posture, and reduce hand tremor and fatigue. The traditional pinch grip is a laparoscopic tool developed by Stryker Inc. widely used during minimal invasive surgery. Twenty-three (13 M, 10 F) participants with no existing upper extremity musculoskeletal disorders or experience performing laparoscopic procedures were selected to perform in this study. During a training session prior to testing, participants performed practice trials in a SAGES FLS trainer with both tools. During data collection, participants performed three evaluation tasks using both handle designs (order was randomized, and each trial completed three times). The tasks consisted of FLS peg transfer, cutting, and suturing tasks.
RESULTS: Feedback from test participants indicated that they significantly preferred the ergonomic pistol grip in every category (p < 0.05); most notably, participants experienced greater degrees of discomfort in their hands after using the pinch grip tool. Furthermore, participants completed cutting and peg transfer tasks in a shorter time duration (p < 0.05) with the pistol grip than with the pinch grip design; there was no significant difference between completion times for the suturing task. Finally, there was no significant interaction between tool type and errors made during trials.
CONCLUSIONS: There was a significant preference for as well as lower pain experienced during use of the pistol grip tool as seen from the survey feedback. Both evaluation tasks (cutting and peg transfer) were also completed significantly faster with the pistol grip tool. Finally, due to the high degree of variability in the error data, it was not possible to draw any meaningful conclusions about the effect of tool design on the number or degree of errors made.

Entities:  

Mesh:

Year:  2014        PMID: 25537377     DOI: 10.1007/s00464-014-4005-9

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  14 in total

1.  The effect of using laparoscopic instruments on muscle activation patterns during minimally invasive surgical training procedures.

Authors:  N E Quick; J C Gillette; R Shapiro; G L Adrales; D Gerlach; A E Park
Journal:  Surg Endosc       Date:  2002-10-29       Impact factor: 4.584

2.  A new platform improving the ergonomics of laparoscopic surgery: initial clinical evaluation of the prototype.

Authors:  Jens J Rassweiler; Ali S Goezen; Akbar Ali Jalal; Michael Schulze; Vito Pansadoro; Giovannalberto Pini; Fernando Kim; Craig Turner
Journal:  Eur Urol       Date:  2011-09-28       Impact factor: 20.096

3.  Improved physical ergonomics of laparoscopic surgery.

Authors: 
Journal:  Minim Invasive Ther Allied Technol       Date:  2004-06       Impact factor: 2.442

4.  The impact of the alexander technique on improving posture and surgical ergonomics during minimally invasive surgery: pilot study.

Authors:  Pramod P Reddy; Trisha P Reddy; Jennifer Roig-Francoli; Lois Cone; Bezalel Sivan; W Robert DeFoor; Krishnanath Gaitonde; Paul H Noh
Journal:  J Urol       Date:  2011-08-19       Impact factor: 7.450

5.  Force response of the fingertip pulp to repeated compression--effects of loading rate, loading angle and anthropometry.

Authors:  E R Serina; C D Mote; D Rempel
Journal:  J Biomech       Date:  1997-10       Impact factor: 2.712

6.  MIS instruments. An experimental comparison of various ergonomic handles and their design.

Authors:  U Matern; M Eichenlaub; P Waller; K Rückauer
Journal:  Surg Endosc       Date:  1999-08       Impact factor: 4.584

7.  Patients benefit while surgeons suffer: an impending epidemic.

Authors:  Adrian Park; Gyusung Lee; F Jacob Seagull; Nora Meenaghan; David Dexter
Journal:  J Am Coll Surg       Date:  2009-12-24       Impact factor: 6.113

8.  Musculoskeletal disorders among visual display terminal workers: individual, ergonomic, and work organizational factors.

Authors:  U Bergqvist; E Wolgast; B Nilsson; M Voss
Journal:  Ergonomics       Date:  1995-04       Impact factor: 2.778

9.  Occupational factors and carpal tunnel syndrome.

Authors:  B A Silverstein; L J Fine; T J Armstrong
Journal:  Am J Ind Med       Date:  1987       Impact factor: 2.214

Review 10.  Minimal access surgery (MAS)-related surgeon morbidity syndromes.

Authors:  D A G Reyes; B Tang; A Cuschieri
Journal:  Surg Endosc       Date:  2005-12-06       Impact factor: 3.453

View more
  7 in total

1.  Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

Authors:  Juan A Sánchez-Margallo; Francisco M Sánchez-Margallo
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-07-10       Impact factor: 2.924

2.  Surgical ergonomics: Assessment of surgeon posture and impact of training device during otolaryngology procedures.

Authors:  Karen L Leung; Rachel M Segal; Jeffrey D Bernstein; Ryan K Orosco; Chris M Reid
Journal:  Laryngoscope Investig Otolaryngol       Date:  2022-08-27

3.  Impact of novel shift handle laparoscopic tool on wrist ergonomics and task performance.

Authors:  Denny Yu; Bethany Lowndes; Missy Morrow; Kenton Kaufman; Juliane Bingener; Susan Hallbeck
Journal:  Surg Endosc       Date:  2015-11-05       Impact factor: 4.584

4.  Postural ergonomics and work-related musculoskeletal disorders in neurosurgery: lessons from an international survey.

Authors:  Georgios Mavrovounis; Torstein R Meling; Jesus Lafuente; Konstantinos N Fountas; Andreas K Demetriades
Journal:  Acta Neurochir (Wien)       Date:  2021-02-17       Impact factor: 2.216

5.  Ergonomics of laparoscopic graspers and the importance of haptic feedback: the surgeons' perspective.

Authors:  Chantal C J Alleblas; Michel P H Vleugels; Theodoor E Nieboer
Journal:  Gynecol Surg       Date:  2016-06-04

6.  Resolution of Thumb Pain following Adoption of Mathieu Needle Holder: An Ergonomic Analysis.

Authors:  Olga Schuth; Jeremy Powers; Wyndell Merritt; Nadia Blanchet
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-04-24

7.  A Fully 3D-Printed Steerable Instrument for Minimally Invasive Surgery.

Authors:  Costanza Culmone; Kirsten Lussenburg; Joost Alkemade; Gerwin Smit; Aimée Sakes; Paul Breedveld
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.