Literature DB >> 25529724

A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry.

Teslima Daşbaşı1, Şerife Saçmacı2, Ahmet Ülgen3, Şenol Kartal3.   

Abstract

A relatively rapid, accurate and precise solid phase extraction method is presented for the determination of cadmium(II) and lead(II) in various food and water samples. Quantitation is carried out by flame atomic absorption spectrometry (FAAS). The method is based on the retention of the trace metal ions on Dowex Marathon C, a strong acid cation exchange resin. Some important parameters affecting the analytical performance of the method such as pH, flow rate and volume of the sample solution; type, concentration, volume, flow rate of the eluent; and matrix effects on the retention of the metal ions were investigated. Common coexisting ions did not interfere on the separation and determination of the analytes. The detection limits (3 σb) for Cd(II) and Pb(II) were found as 0.13 and 0.18 μg L(-1), respectively, while the limit of quantification values (10 σb) were computed as 0.43 and 0.60 μg L(-1) for the same sequence of the analytes. The precision (as relative standard deviation was lower than 4% at 5 μg L(-1) Cd(II) and 10 μg L(-1) Pb(II) levels, and the preconcentration factor was found to be 250. The accuracy of the proposed procedure was verified by analysing the certified reference materials, SPS-WW2 Batch 108 wastewater level 2 and INCT-TL-1 tea leaves, with the satisfactory results. In addition, for the accuracy of the method the recovery studies (⩾ 95%) were carried out. The method was applied to the determination of the analytes in the various natural waters (lake water, tap water, waste water with boric acid, waste water with H2SO4) and food samples (pomegranate flower, organic pear, radish leaf, lamb meat, etc.), and good results were obtained. While the food samples almost do not contain cadmium, they have included lead at low levels of 0.13-1.12 μg g(-1).
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dowex Marathon C; Flame atomic absorption spectrometry; Food samples; Solid phase extraction; Trace element

Mesh:

Substances:

Year:  2014        PMID: 25529724     DOI: 10.1016/j.foodchem.2014.11.049

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  2 in total

1.  Effects of cadmium stress on physiological indexes and fruiting body nutritions of Agaricus brasiliensis.

Authors:  Lingyun Liu; Hua Chen; Jing Yuan; Yixiang Wang; Boqi Weng; Penghu Liu; Guoxue Li
Journal:  Sci Rep       Date:  2021-04-21       Impact factor: 4.379

2.  Heavy metal levels in milk and fermented milk products produced in the Almaty region, Kazakhstan.

Authors:  N B Sarsembayeva; T B Abdigaliyeva; Z A Utepova; A N Biltebay; S Zh Zhumagulova
Journal:  Vet World       Date:  2020-04-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.