Literature DB >> 25529665

Application of handheld and portable spectrometers for screening acrylamide content in commercial potato chips.

Huseyin Ayvaz1, Luis E Rodriguez-Saona2.   

Abstract

The most common methods for acrylamide analysis in foods require the use of LC-MS/MS and GC-MS. Although these methods have great analytical performance, they need intensive sample preparation, highly specialised instrumentation, and are time consuming. In this study, portable and handheld infrared spectrometers were evaluated as rapid methods for screening acrylamide in potato chips and their performances were compared to those of benchtop infrared systems. The acrylamide content of 64 commercial potato chips (169-2453 μg/kg) was determined by LC-MS/MS. Spectral data were collected using mid-infrared (MIR) and near-infrared (NIR) spectrometers. Partial least squares regression (PLSR) calibration models were developed to predict acrylamide levels. Overall, good linear correlation was found between the predicted acrylamide levels and actual measured acrylamide concentrations by LC-MS/MS (rPred > 0.90 and SEP < 100 μg/kg). Our results indicate that portable and handheld spectrometers can be used as simple and rapid alternatives for acrylamide analysis in potato chips.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Acrylamide; Handheld spectrometers; MIR; NIR; Portable spectrometers; Potato chips

Mesh:

Substances:

Year:  2014        PMID: 25529665     DOI: 10.1016/j.foodchem.2014.11.001

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  5 in total

1.  Assessment of the Analytical Performance of Three Near-Infrared Spectroscopy Instruments (Benchtop, Handheld and Portable) through the Investigation of Coriander Seed Authenticity.

Authors:  Claire McVey; Una Gordon; Simon A Haughey; Christopher T Elliott
Journal:  Foods       Date:  2021-04-27

2.  Pharmacokinetic Analysis of Four Bioactive Iridoid and Secoiridoid Glycoside Components of Radix Gentianae Macrophyllae and Their Synergistic Excretion by HPLC-DAD Combined with Second-Order Calibration.

Authors:  Tian-Ming Yang; Yang-Xi Liu; Hai-Yan Fu; Wei Lan; Han-Bo Su; He-Bin Tang; Qiao-Bo Yin; He-Dong Li; Li-Ping Wang; Hai-Long Wu
Journal:  Nat Prod Bioprospect       Date:  2017-11-25

3.  Application of laboratory and portable attenuated total reflectance infrared spectroscopic approaches for rapid quantification of alpaca serum immunoglobulin G.

Authors:  Ibrahim Elsohaby; Jennifer B Burns; Christopher B Riley; R Anthony Shaw; J Trenton McClure
Journal:  PLoS One       Date:  2017-06-26       Impact factor: 3.240

4.  Screening of Acrylamide of Par-Fried Frozen French Fries Using Portable FT-IR Spectroscopy.

Authors:  Didem P Aykas; Alejandra Urtubia; Kevin Wong; Luju Ren; Claudia López-Lira; Luis E Rodriguez-Saona
Journal:  Molecules       Date:  2022-02-09       Impact factor: 4.411

5.  Determination of Cadmium (II) in Aqueous Solutions by In Situ MID-FTIR-PLS Analysis Using a Polymer Inclusion Membrane-Based Sensor: First Considerations.

Authors:  René González-Albarrán; Josefina de Gyves; Eduardo Rodríguez de San Miguel
Journal:  Molecules       Date:  2020-07-29       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.