Literature DB >> 25523865

Permeability study of cancellous bone and its idealised structures.

Ardiyansyah Syahrom1, Mohammed Rafiq Abdul Kadir2, Muhamad Nor Harun3, Andreas Öchsner4.   

Abstract

Artificial bone is a suitable alternative to autografts and allografts, however their use is still limited. Though there were numerous reports on their structural properties, permeability studies of artificial bones were comparably scarce. This study focused on the development of idealised, structured models of artificial cancellous bone and compared their permeability values with bone surface area and porosity. Cancellous bones from fresh bovine femur were extracted and cleaned following an established protocol. The samples were scanned using micro-computed tomography (μCT) and three-dimensional models of the cancellous bones were reconstructed for morphology study. Seven idealised and structured cancellous bone models were then developed and fabricated via rapid prototyping technique. A test-rig was developed and permeability tests were performed on the artificial and real cancellous bones. The results showed a linear correlation between the permeability and the porosity as well as the bone surface area. The plate-like idealised structure showed a similar value of permeability to the real cancellous bones.
Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cancellous bone; Permeability; Trabecular bone; Transports phenomena

Mesh:

Year:  2014        PMID: 25523865     DOI: 10.1016/j.medengphy.2014.11.001

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Modelling of bone fracture and strength at different length scales: a review.

Authors:  Fereshteh A Sabet; Ahmad Raeisi Najafi; Elham Hamed; Iwona Jasiuk
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

2.  Study on mechanical properties and permeability of elliptical porous scaffold based on the SLM manufactured medical Ti6Al4V.

Authors:  Chenglong Shi; Nana Lu; Yaru Qin; Mingdi Liu; Hongxia Li; Haichao Li
Journal:  PLoS One       Date:  2021-03-04       Impact factor: 3.240

3.  Mechanical properties and fluid permeability of gyroid and diamond lattice structures for intervertebral devices: functional requirements and comparative analysis.

Authors:  Anatolie Timercan; Vadim Sheremetyev; Vladimir Brailovski
Journal:  Sci Technol Adv Mater       Date:  2021-04-21       Impact factor: 8.090

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.