BACKGROUND: Insulin pumps are equipped with advanced functions. Intensive training and adherence are required for optimum use of the technology. We aimed to assess the association of various key elements in insulin pump functions on blood glucose control. PATIENTS AND METHODS: Patients on insulin pump therapy were enrolled. Insulin pumps were downloaded (CareLink(®) Pro 3 software; Medtronic Minimed, Northridge, CA), and data were collected over an 8-12-week period. Glycemic control of patients was classified as controlled (hemoglobin A1c [HbA1c] level of 7.5% or less in adults and 8% or less in children) and uncontrolled based on HbA1c level at enrollment. Variables studied were use of sensors and duration, frequency of blood glucose monitoring, Bolus Wizard (Medtronic Minimed) use, frequency of correction boluses, and frequency of cannula changing.
RESULTS: Seventy-two patients were enrolled (50 children). Median age was 12 years for children and 27.5 years for adults. Respective median numbers of blood glucose checks were 4.4 and 3.2 for controlled and uncontrolled children (P<0.021) and 3.1 and 2.8 for controlled and uncontrolled adults, respectively. Respective frequency of Bolus Wizard use per day showed a median of 6 and 4.15 for controlled and uncontrolled children (P<0.001) and 3.8 and 3.5 for controlled and uncontrolled adults. Controlled children wore sensors for longer (5 vs. 2.9 days/week) and did more corrections (3.9 vs. 2.5). There was no difference in the frequency of changing the infusion cannula in children's or adults' groups.
CONCLUSIONS: We conclude that the frequency of blood glucose monitoring and Bolus Wizard use have a favorable association with glycemic control. These observations were more significant in the children's groups. Our data shows that patients with better control tend to bolus more for correction and wear sensors longer.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25513744     DOI: 10.1089/dia.2014.0224

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  8 in total

1.  Adherence to Insulin Pump Behaviors in Young Children With Type 1 Diabetes Mellitus.

Authors:  Susana R Patton; Kimberly A Driscoll; Mark A Clements
Journal:  J Diabetes Sci Technol       Date:  2016-07-10

Review 2.  Boluses in Insulin Therapy.

Authors:  Ralph Ziegler; Guido Freckmann; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-07-10

3.  Insulin Pump Therapy: Patient Practices and Glycemic Outcomes.

Authors:  Dinesh Edem; Patrick McCarthy; Jason M Ng; Maja Stefanovic-Racic; Mary T Korytkowski
Journal:  J Diabetes Sci Technol       Date:  2018-05-29

4.  Comparison of Insulin Pump Bolus Calculators Reveals Wide Variation in Dose Recommendations.

Authors:  Jeanne Buchanan; Jennifer A Zabinsky; Christine Ferrara-Cook; Saleh Adi; Jenise C Wong
Journal:  J Diabetes Sci Technol       Date:  2020-09-01

5.  Impact of new technologies on diabetes care.

Authors:  Elisa Giani; Andrea Enzo Scaramuzza; Gian Vincenzo Zuccotti
Journal:  World J Diabetes       Date:  2015-07-25

6.  Investigating the Association Between Diabetes Distress and Self-Management Behaviors.

Authors:  Aneesah Khan; Pratik Choudhary
Journal:  J Diabetes Sci Technol       Date:  2018-08-12

7.  A Digital Health Intervention (SweetGoals) for Young Adults With Type 1 Diabetes: Protocol for a Factorial Randomized Trial.

Authors:  Catherine Stanger; Tobias Kowatsch; Haiyi Xie; Inbal Nahum-Shani; Frances Lim-Liberty; Molly Anderson; Prabhakaran Santhanam; Sarah Kaden; Briana Rosenberg
Journal:  JMIR Res Protoc       Date:  2021-02-23

8.  Impact of targeted education on managing warning and error signals by children and adolescents with type 1 diabetes using the Accu-Chek Combo Insulin Pump System.

Authors:  Asma Deeb; Nabras Al Qahtani; Amal Al Ali; Mariette Akle
Journal:  Ann Pediatr Endocrinol Metab       Date:  2017-09-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.