S Hodis1, S Kargar2, D F Kallmes3, D Dragomir-Daescu4. 1. From the Department of Mathematics (S.H.), Texas A&M University, Kingsville, Texas Department of Radiology (S.H., D.F.K.). 2. College of Medicine (S.K., D.F.K., D.D.-D.). 3. College of Medicine (S.K., D.F.K., D.D.-D.) Department of Radiology (S.H., D.F.K.). 4. College of Medicine (S.K., D.F.K., D.D.-D.) Division of Engineering (D.D.-D.), Mayo Clinic, Rochester, Minnesota. DragomirDaescu.Dan@mayo.edu.
Abstract
BACKGROUND AND PURPOSE: The reconstruction of aneurysm geometry is a main factor affecting the accuracy of hemodynamics simulations in patient-specific aneurysms. We analyzed the effects of the inlet artery length on intra-aneurysmal flow estimations by using 10 ophthalmic aneurysm models. MATERIALS AND METHODS: We successively truncated the inlet artery of each model, first at the cavernous segment and second at the clinoid segment. For each aneurysm, we obtained 3 models with different artery lengths: the originally segmented geometry with the longest available inlet from scans and 2 others with successively shorter artery lengths. We analyzed the velocity, wall shear stress, and the oscillatory shear index inside the aneurysm and compared the 2 truncations with the original model. RESULTS: We found that eliminating 1 arterial turn resulted in root mean square errors of <18% with no visual differences for the contours of the flow parameters in 8 of the 10 models. In contrast, truncating at the second turn led to root mean square errors between 18% and 32%, with consistently large errors for wall shear stress and the oscillatory shear index in 5 of the 10 models and visual differences for the contours of the flow parameters. For 3 other models, the largest errors were between 43% and 55%, with large visual differences in the contour plots. CONCLUSIONS: Excluding 2 arterial turns from the inlet artery length of the ophthalmic aneurysm resulted in large quantitative differences in the calculated velocity, wall shear stress, and oscillatory shear index distributions, which could lead to erroneous conclusions if used clinically.
BACKGROUND AND PURPOSE: The reconstruction of aneurysm geometry is a main factor affecting the accuracy of hemodynamics simulations in patient-specific aneurysms. We analyzed the effects of the inlet artery length on intra-aneurysmal flow estimations by using 10 ophthalmic aneurysm models. MATERIALS AND METHODS: We successively truncated the inlet artery of each model, first at the cavernous segment and second at the clinoid segment. For each aneurysm, we obtained 3 models with different artery lengths: the originally segmented geometry with the longest available inlet from scans and 2 others with successively shorter artery lengths. We analyzed the velocity, wall shear stress, and the oscillatory shear index inside the aneurysm and compared the 2 truncations with the original model. RESULTS: We found that eliminating 1 arterial turn resulted in root mean square errors of <18% with no visual differences for the contours of the flow parameters in 8 of the 10 models. In contrast, truncating at the second turn led to root mean square errors between 18% and 32%, with consistently large errors for wall shear stress and the oscillatory shear index in 5 of the 10 models and visual differences for the contours of the flow parameters. For 3 other models, the largest errors were between 43% and 55%, with large visual differences in the contour plots. CONCLUSIONS: Excluding 2 arterial turns from the inlet artery length of the ophthalmic aneurysm resulted in large quantitative differences in the calculated velocity, wall shear stress, and oscillatory shear index distributions, which could lead to erroneous conclusions if used clinically.
Authors: C Karmonik; O Diaz; R Klucznik; R G Grossman; Y J Zhang; G Britz; N Lv; Q Huang Journal: J Neurointerv Surg Date: 2014-04-10 Impact factor: 5.836
Authors: Juan R Cebral; Marcelo A Castro; Sunil Appanaboyina; Christopher M Putman; Daniel Millan; Alejandro F Frangi Journal: IEEE Trans Med Imaging Date: 2005-04 Impact factor: 10.048
Authors: Juan R Cebral; Christopher M Putman; Marcus T Alley; Thomas Hope; Roland Bammer; Fernando Calamante Journal: J Eng Math Date: 2009-08-01 Impact factor: 1.509
Authors: Kristian Valen-Sendstad; Aslak W Bergersen; Yuji Shimogonya; Leonid Goubergrits; Jan Bruening; Jordi Pallares; Salvatore Cito; Senol Piskin; Kerem Pekkan; Arjan J Geers; Ignacio Larrabide; Saikiran Rapaka; Viorel Mihalef; Wenyu Fu; Aike Qiao; Kartik Jain; Sabine Roller; Kent-Andre Mardal; Ramji Kamakoti; Thomas Spirka; Neil Ashton; Alistair Revell; Nicolas Aristokleous; J Graeme Houston; Masanori Tsuji; Fujimaro Ishida; Prahlad G Menon; Leonard D Browne; Stephen Broderick; Masaaki Shojima; Satoshi Koizumi; Michael Barbour; Alberto Aliseda; Hernán G Morales; Thierry Lefèvre; Simona Hodis; Yahia M Al-Smadi; Justin S Tran; Alison L Marsden; Sreeja Vaippummadhom; G Albert Einstein; Alistair G Brown; Kristian Debus; Kuniyasu Niizuma; Sherif Rashad; Shin-Ichiro Sugiyama; M Owais Khan; Adam R Updegrove; Shawn C Shadden; Bart M W Cornelissen; Charles B L M Majoie; Philipp Berg; Sylvia Saalfield; Kenichi Kono; David A Steinman Journal: Cardiovasc Eng Technol Date: 2018-09-10 Impact factor: 2.495