Literature DB >> 25499716

Carotid plaque morphometric assessment with three-dimensional ultrasound imaging.

Khalid AlMuhanna1, Md Murad Hossain2, Limin Zhao3, Jonathan Fischell4, Gregory Kowalewski3, Moira Dux5, Siddhartha Sikdar2, Brajesh K Lal6.   

Abstract

OBJECTIVE: As investigations into nonsurgical treatment for atherosclerosis expand, the measurement of plaque regression and progression has become an important end point to evaluate. Measurements of three-dimensional (3D) plaque volume are more reliable and sensitive to change than are traditional estimates of stenosis severity or cross-sectional area. 3D ultrasound (3D US) imaging may allow monitoring of plaque volume changes but has not been used routinely due to the cumbersome motorized units required to drive transducers. We investigated the variability, reliability, and the least amount of change detectable by 1D plaque measures, as well as 2D and 3D measures of plaque morphometry, that can be applied in a clinical environment.
METHODS: 3D US imaging was obtained in 10 patients with carotid stenosis. The lumen and outer wall boundaries were outlined in serial cross-sectional images 1 mm apart. Three observers manually segmented vessel wall volumes (VWVs), and the segmentation was repeated again 4 weeks later. This allowed measurement of interobserver and intraobserver variability of 6 pairs of observations. We measured Bland-Altman statistics, intraclass correlation coefficients, coefficient of variability, and the minimum detectable plaque change for each morphometric measure.
RESULTS: The mean VWV of carotid lesions in the study was 1276.8 mm(3) (range, 620.6-1956.3 mm(3)). Bland-Altman plots demonstrated low interobserver and intraobserver variability. The interobserver variability of volume measurements as a function of mean volume was 14.8% and interobserver variability was 8.9%. Reliability was 87% as quantified by the interclass correlation and was 95% by the intraclass correlation. The least detectable change in VWV was 12.9% for interobserver variability and 4.5% for intraobserver variability for the three observers.
CONCLUSIONS: Carotid plaque diameter measurements from B-mode images have high variability. Plaque burden, as estimated by VWV, can be measured reliably with a 3D US technique using a clinical scanner. The volumetric change, with 95% confidence, that must be observed to establish that a plaque has undergone growth or regression is ∼12.9% for different observers and 4.5% for the same observer performing the follow-up study.
Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25499716     DOI: 10.1016/j.jvs.2014.10.003

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

Review 1.  New Insights into Dialysis Vascular Access: Molecular Targets in Arteriovenous Fistula and Arteriovenous Graft Failure and Their Potential to Improve Vascular Access Outcomes.

Authors:  Timmy Lee; Sanjay Misra
Journal:  Clin J Am Soc Nephrol       Date:  2016-07-11       Impact factor: 8.237

2.  Noninvasive characterization of carotid plaque strain.

Authors:  Amir A Khan; Siddhartha Sikdar; Thomas Hatsukami; Juan Cebral; Michael Jones; John Huston; George Howard; Brajesh K Lal
Journal:  J Vasc Surg       Date:  2017-03-06       Impact factor: 4.268

3.  Histopathologic Validation of Grayscale Carotid Plaque Characteristics Related to Plaque Vulnerability.

Authors:  Carol C Mitchell; James H Stein; Thomas D Cook; Shahriar Salamat; Xiao Wang; Tomy Varghese; Daren C Jackson; Carolina Sandoval Garcia; Stephanie M Wilbrand; Robert J Dempsey
Journal:  Ultrasound Med Biol       Date:  2016-10-05       Impact factor: 2.998

4.  Carotid plaque inflammatory activity assessed by 2-[18F]FDG-PET imaging decrease after a neurological thromboembolic event.

Authors:  Laerke Urbak; Rasmus S Ripa; Benjamin V Sandholt; Andreas Kjaer; Henrik Sillesen; Martin Graebe
Journal:  EJNMMI Res       Date:  2021-03-23       Impact factor: 3.138

5.  Risk factors for changes in carotid intima media thickness and plaque over 5 years in women with systemic lupus erythematosus.

Authors:  Apinya Lertratanakul; Julia Sun; Peggy W Wu; Jungwha Lee; Alan Dyer; William Pearce; David McPherson; Kim Sutton-Tyrrell; Trina Thompson; Emma Barinas-Mitchell; Rosalind Ramsey-Goldman
Journal:  Lupus Sci Med       Date:  2021-12

Review 6.  Imaging the carotid atherosclerotic plaque.

Authors:  Sandra Neumann; Elena G Milano; Chiara Bucciarelli-Ducci; Giovanni Biglino
Journal:  Vasc Biol       Date:  2019-06-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.