Literature DB >> 25491933

Results of "elephant trunk" total aortic arch replacement using a multi-branched, collared graft prosthesis.

Stefan R B Schneider1, Angelo M Dell'Aquila2, Ali Akil2, Dominik Schlarb2, Guiseppe Panuccio3, Sven Martens2, Andreas Rukosujew2.   

Abstract

We report on our experience with a simplified elephant trunk (ET) procedure with a multi-branched prosthesis (Vascutek(®) Siena™ Collared Graft). It consists of a proximal portion (20 cm) with prefabricated side branches, a collar and a distal portion (30 cm). The collar, which can be trimmed into any desired diameter, constitutes the suture portion to the descending aorta. Radiopaque markers in the distal portion indicate the landing zone. Between January 2011 and June 2013, 20 consecutive patients (10 women; mean age, 66 ± 9.3 years) underwent ET procedure, including 6 re-do cases. Underlying aortic diseases were acute dissection (n = 6), chronic dissection (n = 4), aneurysm (n = 8) and PAU (n = 2). Mean preoperative diameter of the descending aorta was 49.1 ± 12.9 mm (range 74.7-29.7 mm). Concomitant procedures included ascending aortic replacement in 16 patients; root replacement in 2; AVR in 2, CABG in 3 and mitral repair in 1 patient. CPB time was 263 ± 94 min; mean duration of ACP was 65 ± 14 min. Two patients died on POD 8 and 78, respectively. Major adverse events included stroke (n = 1), resternotomy for bleeding (n = 2), renal failure requiring temporary dialysis (n = 1) and recurrent nerve paresis (n = 2). After a mean follow-up of 10 ± 8 months, all discharged patients were alive. Seven patients underwent stent-graft implantation of the descending aorta and one patient underwent open descending aortic replacement. The last generation of multi-branched arch prosthesis and especially the Vascutek(®) Siena™ Collared Graft make ET procedure a reasonable treatment option even in patients with acute aortic dissection.

Entities:  

Keywords:  Aortic arch replacement; Aortic dissection; Ascending aortic aneurysm; Elephant trunk procedure

Mesh:

Year:  2014        PMID: 25491933     DOI: 10.1007/s00380-014-0612-6

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  27 in total

1.  Late complications of tissue glues in aortic surgery.

Authors:  J A Bingley; M A Gardner; E G Stafford; T K Mau; P G Pohlner; R K Tam; H Jalali; P J Tesar; M F O'Brien
Journal:  Ann Thorac Surg       Date:  2000-06       Impact factor: 4.330

2.  TREATMENT OF DISSECTING ANEURYSMS OF THE AORTA WITHOUT SURGERY.

Authors:  M W WHEAT; R F PALMER; T D BARTLEY; R C SEELMAN
Journal:  J Thorac Cardiovasc Surg       Date:  1965-09       Impact factor: 5.209

3.  Thromboelastometry Based Early Goal-Directed Coagulation Management Reduces Blood Transfusion Requirements, Adverse Events, and Costs in Acute Type A Aortic Dissection: A Pilot Study.

Authors:  Alexander A Hanke; Ulf Herold; Daniel Dirkmann; Konstantinos Tsagakis; Heinz Jakob; Klaus Görlinger
Journal:  Transfus Med Hemother       Date:  2012-03-15       Impact factor: 3.747

4.  Flanged elephant trunk technique at distal anastomosis for total arch replacement with multibranched arch graft.

Authors:  Yasunori Iida; Nobusato Koizumi; Katsuhiko Matsuyama; Hitoshi Ogino
Journal:  Ann Vasc Surg       Date:  2013-03-29       Impact factor: 1.466

5.  Open chest management after cardiac operations: outcome and timing of delayed sternal closure.

Authors:  Udo Boeken; Alexander Assmann; Arash Mehdiani; Payam Akhyari; Artur Lichtenberg
Journal:  Eur J Cardiothorac Surg       Date:  2011-03-31       Impact factor: 4.191

6.  Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion.

Authors:  Kazumasa Orihashi; Taijiro Sueda; Kenji Okada; Katsuhiko Imai
Journal:  Eur J Cardiothorac Surg       Date:  2004-11       Impact factor: 4.191

7.  Angiotensin II blockade and aortic-root dilation in Marfan's syndrome.

Authors:  Benjamin S Brooke; Jennifer P Habashi; Daniel P Judge; Nishant Patel; Bart Loeys; Harry C Dietz
Journal:  N Engl J Med       Date:  2008-06-26       Impact factor: 91.245

8.  Rationale and technique for replacement of the ascending aorta, arch, and distal aorta using a modified elephant trunk procedure.

Authors:  L G Svensson
Journal:  J Card Surg       Date:  1992-12       Impact factor: 1.620

9.  Evolving selective cerebral perfusion for aortic arch replacement: high flow rate with moderate hypothermic circulatory arrest.

Authors:  Kenji Minatoya; Hitoshi Ogino; Hitoshi Matsuda; Hiroaki Sasaki; Hiroshi Tanaka; Junjiro Kobayashi; Toshikatsu Yagihara; Soichiro Kitamura
Journal:  Ann Thorac Surg       Date:  2008-12       Impact factor: 4.330

10.  Lower heart rate in the early postoperative period does not correlate with long-term outcomes after repair of type A acute aortic dissection.

Authors:  Tetsu Ohnuma; Naoyuki Kimura; Yusuke Sasabuchi; Kayo Asaka; Junji Shiotsuka; Tetsuya Komuro; Hideyuki Mouri; Alan T Lefor; Hideo Adachi; Masamitsu Sanui
Journal:  Heart Vessels       Date:  2014-02-25       Impact factor: 2.037

View more
  3 in total

1.  Analysis of early and long-term outcomes of acute type A aortic dissection according to the new international aortic arch surgery study group recommendations.

Authors:  Andrea Colli; Massimiliano Carrozzini; Marco Galuppo; Marina Comisso; Francesca Toto; Dario Gregori; Gino Gerosa
Journal:  Heart Vessels       Date:  2015-11-17       Impact factor: 2.037

2.  Early outcomes in re-do operation after acute type A aortic dissection: results from the multicenter REAAD database.

Authors:  Angelo M Dell'Aquila; Francesco Pollari; Khalil Fattouch; Giuseppe Santarpino; Julia Hillebrand; Stefan Schneider; Jan Landwerht; Giuseppe Nasso; Renato Gregorini; Mauro Del Giglio; Elisa Mikus; Alberto Albertini; Heinz Deschka; Theodor Fischlein; Sven Martens; Alina Gallo; Giovanni Concistrè; Giuseppe Speziale; Tommaso Regesta
Journal:  Heart Vessels       Date:  2016-10-21       Impact factor: 2.037

3.  Arch replacement with collared elephant trunks: The Siena approach.

Authors:  Eugenio Neri; Luigi Muzzi; Enrico Tucci; Marco Cini; Lucio Barabesi; Giulio Tommasino; Carmelo Ricci
Journal:  JTCVS Tech       Date:  2020-11-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.