Literature DB >> 25491926

Non-linear image blending improves visualization of head and neck primary squamous cell carcinoma compared to linear blending in dual-energy CT.

J-E Scholtz1, K Hüsers2, M Kaup2, M Albrecht2, B Schulz2, C Frellesen2, B Bodelle2, J Wagenblast3, J M Kerl2, R W Bauer2, T Lehnert2, T J Vogl2, J L Wichmann2.   

Abstract

AIM: To compare non-linear and linear image-blending post-processing techniques in dual-energy CT (DECT) of primary head and neck squamous cell carcinoma (SCC) regarding subjective and objective image quality.
MATERIALS AND METHODS: Head and neck DECT studies from 69 patients (48 male, 21 female; mean age 62.3 years) were retrospectively evaluated. All tumour lesions were histologically confirmed SCC. Linearly blended 80/140 kVp images series with varying weighting factors of 0.3 (M_0.3), 0.6 and 0.8 were compared with non-linearly blended images. Attenuation of tumour lesion, various soft-tissue structures, the internal jugular vein, and image noise were measured, tumour signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Overall image quality, delineation of tumour lesion, image sharpness, and noise level were rated individually by three radiologists using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficient (ICC).
RESULTS: Enhancement of tumour lesions (non-linear, 137.5 ± 20.1 HU; M_0.3, 92.7 ± 14.4 HU; M_0.6, 110 ± 15.4 HU; M_0.8, 123 ± 18.2 HU), CNR (non-linear, 12 ± 8; M_0.3, 4 ± 4.7; M_0.6, 7.5 ± 5.5; M_0.8, 8 ± 5.5), subjective overall image quality and tumour delineation were significantly increased (all p < 0.001) with the non-linear blending technique compared to all investigated linear blending weighting factors. Overall interobserver agreement was substantial (ICC 0.70; 95% CI: 0.66-0.73).
CONCLUSION: Post-processing of DECT using a non-linear blending technique provides improved objective and subjective image quality of head and neck SCC compared to linearly blended images series.
Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25491926     DOI: 10.1016/j.crad.2014.10.018

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  5 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

2.  Enhanced gray-white matter differentiation on non-enhanced CT using a frequency selective non-linear blending.

Authors:  Georg Bier; Malte Niklas Bongers; Hendrik Ditt; Benjamin Bender; Ulrike Ernemann; Marius Horger
Journal:  Neuroradiology       Date:  2016-03-10       Impact factor: 2.804

3.  Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography.

Authors:  Jan-Erik Scholtz; Moritz Kaup; Johannes Kraft; Eva-Maria Nöske; Friedrich Scheerer; Boris Schulz; Iris Burck; Jens Wagenblast; J Matthias Kerl; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Neuroradiology       Date:  2015-03-26       Impact factor: 2.804

4.  Dual-energy computed tomography of the neck-optimizing tube current settings and radiation dose using a 3D-printed patient phantom.

Authors:  Torsten Diekhoff; Michael Scheel; Wiebke Kress; Bernd Hamm; Paul Jahnke
Journal:  Quant Imaging Med Surg       Date:  2021-04

Review 5.  Dual-Energy CT in Head and Neck Imaging.

Authors:  Elise D Roele; Veronique C M L Timmer; Lauretta A A Vaassen; Anna M J L van Kroonenburgh; A A Postma
Journal:  Curr Radiol Rep       Date:  2017-03-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.