Flow diversion is increasingly being utilized for the treatment of internal carotid artery (ICA) aneurysms. The purpose of this study was to evaluate the impact of endovascular technique--flow diversion versus stent-assisted coiling (SAC) on fluoroscopy time in patients treated for wide-neck paraclinoid ICA aneurysms. A retrospective review identified the 20 most recent consecutive patients treated for wide-neck paraclinoid ICA aneurysms by flow diversion and SAC respectively. Fluoroscopy time, cumulative dose area-product (DAP), contrast usage, intra-procedural complications, and total procedure time were collected and compared between the two treatment techniques. Treatment groups were comparable in terms of demographics, contrast usage, and clinical and angiographic outcomes. Flow diversion was associated with a significant reduction in fluoroscopy time (52.0 minutes versus 77.4 minutes), and demonstrated a strong trend towards shorter total procedure time (172 minutes versus 202 minutes). Average patient radiation exposure as measured by DAP was lower in the flow diversion group, 13225 mGy(x)cm(2) versus 15124 mGy(x)cm(2), although this finding was not statistically significant. There was no significant difference in contrast usage between the two groups, 152 ml and 159 (flow diversion and SAC respectively). The rate of complete aneurysm occlusion was higher in the flow diversion group (80% versus 60%). Endovascular treatment of paraclinoid ICA aneurysms with flow diversion is associated with shorter fluoroscopy times compared to stent-assisted coiling. There is also a likely reduction in overall procedure time. These results should be considered when recommending a treatment course for patients with such lesions.

Entities:  

Keywords:  flow diversion; fluoroscopy time; paraclinoid aneurysm; stent-assisted coiling

Mesh:

Year:  2014        PMID: 25489897      PMCID: PMC4291792          DOI: 10.15274/NRJ-2014-10094

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  18 in total

1.  Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results.

Authors:  I Saatci; K Yavuz; C Ozer; S Geyik; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-19       Impact factor: 3.825

2.  Radiation dose analysis of large and giant internal carotid artery aneurysm treatment with the pipeline embolization device versus traditional coiling techniques.

Authors:  Geoffrey P Colby; Li-Mei Lin; Neelesh Nundkumar; Bowen Jiang; Judy Huang; Rafael J Tamargo; Alexander L Coon
Journal:  J Neurointerv Surg       Date:  2014-04-08       Impact factor: 5.836

3.  Comparison of 2-year angiographic outcomes of stent- and nonstent-assisted coil embolization in unruptured aneurysms with an unfavorable configuration for coiling.

Authors:  G Hwang; H Park; J S Bang; S-C Jin; B C Kim; C W Oh; H S Kang; M H Han; O-K Kwon
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

4.  The pipeline embolization device for the intracranial treatment of aneurysms trial.

Authors:  P K Nelson; P Lylyk; I Szikora; S G Wetzel; I Wanke; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-09       Impact factor: 3.825

Review 5.  Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis.

Authors:  Waleed Brinjikji; Mohammad H Murad; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2013-01-15       Impact factor: 7.914

6.  Flow diversion versus traditional aneurysm embolization strategies: analysis of fluoroscopy and procedure times.

Authors:  Nohra Chalouhi; Jeffrey F McMahon; Lea A Moukarzel; Robert M Starke; Pascal Jabbour; Aaron S Dumont; Stavropoula Tjoumakaris; Eric L Gingold; Robert Rosenwasser; L Fernando Gonzalez
Journal:  J Neurointerv Surg       Date:  2013-05-25       Impact factor: 5.836

7.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

8.  Comparison of flow diversion and coiling in large unruptured intracranial saccular aneurysms.

Authors:  Nohra Chalouhi; Stavropoula Tjoumakaris; Robert M Starke; L Fernando Gonzalez; Ciro Randazzo; David Hasan; Jeffrey F McMahon; Saurabh Singhal; Lea A Moukarzel; Aaron S Dumont; Robert Rosenwasser; Pascal Jabbour
Journal:  Stroke       Date:  2013-05-30       Impact factor: 7.914

9.  Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience.

Authors:  Mariangela Piano; Luca Valvassori; Luca Quilici; Guglielmo Pero; Edoardo Boccardi
Journal:  J Neurosurg       Date:  2012-11-23       Impact factor: 5.115

10.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

View more
  2 in total

1.  Investigating the parameters that affect the radiation exposure and establishing typical values based on procedure complexity for cerebral angiography and brain aneurysm embolization.

Authors:  Chadia Rizk; Ghassan Abi Chedid; Christine Salem; Jad Farah
Journal:  Neuroradiology       Date:  2020-10-14       Impact factor: 2.804

2.  Balloon-Assisted Coils Embolization for Ophthalmic Segment Aneurysms of the Internal Carotid Artery.

Authors:  Liang Chaohui; Zhang Guang Yu; Hou Kai
Journal:  Front Neurol       Date:  2021-04-15       Impact factor: 4.003

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.