Literature DB >> 25489305

Left ventricular to right atrial shunt (Gerbode defect): congenital versus acquired.

Shi-Min Yuan1.   

Abstract

INTRODUCTION: Congenital left ventricular to right atrial (LV-RA) shunt (Gerbode defect) is rare, while acquired LV-RA shunt has been increasingly reported. As yet, systematically incorporated data of the LV-RA shunt have not been presented. AIM: To present the clinical features, diagnostic challenge and management strategies of congenital and acquired LV-RA shunts.
MATERIAL AND METHODS: The data source was based on a comprehensive literature retrieval of the LV-RA shunt in the period 1990-2013.
RESULTS: In comparison with the acquired Gerbode defect, the congenital Gerbode defect group of patients were younger and were associated more often with additional congenital disorders. Previous cardiac surgery and infective endocarditis were the two major aetiologies of the occurrence of the acquired shunts. Paravalvular abscess was associated in 10.2% and atrioventricular block in 13.6% of the acquired group patients. Transoesophageal echocardiography showed a higher diagnostic accuracy, lower missed diagnosis and lower inclusive diagnosis rates, in comparison to transthoracic echocardiography, but the misdiagnosis rates of the two modalities did not differ from each other. Four (4.5%) of the acquired group patients were complicated by atrioventricular block following surgical or interventional closure of the shunt. Eight (9.1%) patients died in the acquired group, but no patient died in the congenital group.
CONCLUSIONS: The diagnosis of an LV-RA shunt is quite challenging, especially in the context of coexisting abnormalities including an additional intracardiac shunt, tricuspid regurgitation, pulmonary artery hypertension and infective endocarditis, which have to be carefully differentiated from the shunt by further investigations. A better control of infective complications and careful manoeuvres during surgery may help to keep the LV-RA-sensitive septum intact.

Entities:  

Keywords:  congenital heart defects; diagnostic errors; echocardiography; endocarditis; septal occluder device

Year:  2014        PMID: 25489305      PMCID: PMC4252310          DOI: 10.5114/pwki.2014.45146

Source DB:  PubMed          Journal:  Postepy Kardiol Interwencyjnej        ISSN: 1734-9338            Impact factor:   1.426


Introduction

The left ventricular to right atrial (LV-RA) shunt was firstly reported by Gerbode et al. [1] in 1958, and so the lesion was termed as the Gerbode defect. The left ventricular to right atrial shunts can be either congenital or acquired in nature. The term “Gerbode defect” should refer to the congenital rather than to the acquired shunt. Congenital LV-RA shunt is rare; however, acquired shunt has been increasingly reported as a result of infective endocarditis (IE), trauma, valve replacement, myocardial infarction, etc. [2]. The diagnosis of an LV-RA shunt is always challenging due to the limited diagnostic accuracy of transthoracic echocardiography (TTE). The remarkable misdiagnosis, missed diagnosis and inclusive diagnosis rates for this conventional non-invasive technique have made it less convincing as a diagnostic tool for a LV-RA shunt. Questions have been posed regarding the shortcomings of TTE and the potentially complementary alternatives for correct diagnosis. The coexistence of an alternative intracardiac shunt [3, 4], tricuspid regurgitation [5], pulmonary hypertension [6], etc. would make the diagnosis of an LV-RA shunt even more difficult. A delayed diagnosis may inevitably lead to worsening condition of the patient. Therefore, it is important to always bear in mind an LV-RA shunt when an unexplained turbulent flow is visualised in the right cardiac chamber, and further investigations by transoesophageal echocardiography (TEE), magnetic resonance imaging (MRI), computed tomographic angiography, etc. are warranted. Moreover, the predominant pathogenesis of the acquired LV-RA shunt, either postoperative or infective, was associated with considerable morbidity and mortality rates. A correct diagnosis and early treatment of the LV-RA shunt, particularly the acquired type, may lead to better clinical outcomes in such patients.

Aim

This study aims to present the clinical features, diagnostic challenge and management strategies of congenital and acquired LV-RA shunts.

Material and methods

A comprehensive literature retrieval was made in the PubMED database. The search terms included “Gerbode defect” and “LV-RA defect” with additional filters of “human” and “English” without year limit. A literature search of the Highwire Press, Google search engine and additional references cited in the articles completed the article collection. Atrial fistula and aorta-atrium fistula were primarily excluded from this study. The search ended on December 31, 2013. The retrieval resulted in a collection of 111 articles [2-113], which included 77 (59.3%) case reports [3, 5–7, 9, 12–14, 16, 17, 19–23, 25–28, 30, 33, 35–37, 39, 42, 44–54, 57, 59–61, 63–67, 71, 76–80, 82, 84–89, 92–97, 99–107, 110–112] (including 8 (7.4%) case reports in the name of “letter to the editor” [5, 25, 26, 30, 79, 84, 92, 111]), 17 (17.6%) medical images [2, 10, 11, 15, 22, 32, 40, 41, 43, 58, 69, 70, 72, 74, 98, 108, 109], 5 (4.6%) case series [8, 18, 34, 38, 73], 4 (3.7%) original articles [24, 62, 75, 105], 2 (1.9%) echo rounds [55, 91], 2 (1.9%) “how-to-do's” [68, 81], 2 (0.9%) conference abstracts [56, 90], 1 (0.9%) quiz [4] and 1 (0.9%) journal supplement abstract [31]. Exclusion criteria included duplicate publications in 3 [69, 91, 93], and a large cohort of LV-RA shunts with a disputable congenital or acquired aetiology and potentially considerable bias on the statistical analysis of the present paper [105], a “mirror-image” Gerbode defect [109] and an Ebstein's anomaly-associated Gerbode-like defect, which could be a real VSD in a format of Gerbode defect due to severe displacement of the septal tricuspid leaflet [29]. As a result, 104 articles regarding 121 patients with a LV-RA shunt were included in this study. Diagnostic errors by echocardiography include misdiagnosis, missed diagnosis and inclusive diagnosis. A mis-diagnosis is a diagnosis by echocardiography, which does not conform to the result of the definite diagnosis. A missed diagnosis, also called a false negative diagnosis, is when the shunt is not found by echocardiography but is disclosed by alternative diagnostic means. An inclusive diagnosis is when the shunt is visualised by echocardiography but the origin and nature of the shunt cannot be determined and other diagnostic approaches are required to confirm these.

Statistical analysis

Measurement data were expressed in mean ± standard deviation with range and median values and were compared by independent sample t-test. Categorical variables were compared by Fisher exact test. A value of p < 0.05 was considered statistically significant.

Results

Patient information

Aetiologies of the LV-RA shunts were congenital in 32 (26.4%) cases [6, 7, 9–28, 30–32], acquired in 88 (72.7%) cases [2, 3, 7, 8, 18, 31, 33–68, 70–90, 92, 94–104, 106–108, 110, 111] and unknown in 1 (0.8%) patient [112], respectively. A significant difference was noted in the percentages between congenital and acquired LV-RA shunts (χ2 = 52.3, p < 0.0001). Mean patients’ age was 50.1 ±22.6 years (range: 1 month–86 years; median 63 years) (n = 112). Of the patients whose gender could be tracked, there were 73 (62.4%) males and 44 (37.6%) females, with a male-to-female ratio of 1.66: 1. A significant age difference was found between genders (53.3 ±21.2 years vs. 43.8 ±24.7 years, p = 0.0470) and between patients with a congenital and an acquired LV-RA shunt (35.0 ±22.7 years vs. 54.7 ±23.1 years, p < 0.0001). There was no difference in the male-to-female ratio between congenital and acquired group patients (1.31 (16: 13) vs. 1.23 (56: 31), χ2 = 0.8, p = 0.3770).

Clinical characteristics

Over 25% of the congenital and 21.3% of the acuired group patients were asymptomatic. The most common symptoms of the symptomatic patients were dyspnoea (7 patients (21.9%) vs. 14 patients (15.9%)) and congestive heart failure (5 patients (15.6%) vs. 13 patients (14.8%)) in both groups. Fever (8 patients, 9.1%) was a more common symptom in the acquired group patients. Aortic wall abscesses were seen in 9 patients (10.2%) [33, 39, 40, 53, 55, 58, 78, 87, 104] and atrioventricular block in 12 (13.6%) (2 were with aortic wall abscess [39, 61], 6 were third degree [39, 61, 82, 89, 99, 102] and 6 were first degree [18, 44, 48, 86, 101, 102]) of the acquired group patients but in none in the congenital patients. There was significant dominance of right atrium dilation, right ventricle dilation, tricuspid regurgitation and pulmonary artery hypertension (Table I). The prevalence of right atrium dilation did not differ between the congenital and acquired groups (20/23 (87.0%) vs. 23/31 (74.2%), χ2 = 1.3, p = 0.2500).
Table I

Comparisons of major cardiac structural and haemodynamic changes in relation to the left ventricular to right atrial shunt

VariableYes, n (%)No, n (%)χ2 Value of p
Right atrial dilation (n = 54)40 (74.1)14 (25.9)25.0< 0.0001
Right ventricular dilation (n = 31)22 (71.0)9 (29.0)19.90.0010
Tricuspid regurgitation (n = 32)27 (84.4)5 (15.6)30.3< 0.0001
Pulmonary artery hypertension (n = 24)20 (83.3)4 (16.7)30.3< 0.0001
Comparisons of major cardiac structural and haemodynamic changes in relation to the left ventricular to right atrial shunt The underlying risk factors for the acquired LV-RA shunt can be divided into six categories: postoperative 52 (59.1%) (including 39 (75%) heart valve operations, 13 (25%) congenital heart defect repair (1 patient had concurrent AVR and VSD repair) and 1 (1.9%) ascending aorta replacement); infective 25 (28.4%); ischaemic 5 (5.7%); iatrogenic 4 (4.5%); and traumatic 2 (2.3%) (Figure 1).
Figure 1

Distribution of aetiologies for acquired left ventricular to right atrial shunt

Distribution of aetiologies for acquired left ventricular to right atrial shunt The onset time of the acquired LV-RA shunt was reported in 51 patients. In 7 (13.7%) patients, the LV-RA shunts developed immediately after cardiac interventions and the onset time was recorded as “0”. In general, the LV-RA shunts developed at 22.0 ±41.5 (median: 2; range: 0–156) months (n = 51) after the cardiac operation, interventional therapy, or onset of IE. There were 45 major heart valve operations including 26 (57.8%) aortic, 18 (40%) mitral and 1 (2.2%) pulmonary valve operation. The indications for aortic valve operations were not described in 12 patients. Of the remaining 14 patients, 5 (35.7%) patients were for IE, 4 (28.6%) patients for rheumatic heart disease (aortic valve stenosis), 2 (14.3%) for bicuspid aortic valve, 2 (14.3%) for aortic dissection and 1 (7.1%) was a redo-aortic valve replacement (AVR) for prosthetic aortic valve dysfunction (5 patients had concurrent AVR and mitral valve replacement and 1 patient had concurrent AVR and congenital VSD repair). Of the 18 patients with a mitral valve operation, the surgical indications were not stated in 4 patients. Of the remaining 14 patients, 6 (42.9%) were for rheumatic heart disease (mitral valve stenosis), 3 (21.4%) for mitral regurgitation (1 was mitral valve prolapse), 2 (14.3%) for IE, 2 (14.3%) were reoperations for prosthetic mitral valve thrombus clearance and 1 (7.1%) for mitral valve cleft repair. The indication in the only patient for pulmonary valve replacement was IE. The frequencies of IE as an indication for a valve operation were 35.7% (5/14), 14.3% (2/14) and 100% (1/1) for aortic, mitral and pulmonary valve replacement, respectively. No significant difference was found between the former two frequencies (χ2 = 1.7, p = 0.1900). Of the above 8 IE patients, the frequencies of aortic, mitral and pulmonary valve replacements represented 62.5% (5/8), 25% (2/8) and 12.5% (1/8), respectively. No significance was noted either between the former two (χ2 = 2.3, p = 0.1310) or between the three frequencies (χ2 = 4.9, p = 0.0870). The IE was a direct cause of an acquired LV-RA shunt in 25 patients and was an indirect cause in 8. In addition, 2 cases of remote IE (one of them was recurrent aortic valve IE following mitral IE) did not constitute the direct cause of a LV-RA shunt. Aortic valve IE was the most common in both direct and indirect causes of the LV-RA shunt. Tricuspid IE was a more common direct cause. Of all the patients of IE, the underlying pathogens were not indicated in 8 patients and no microorganism was shown by blood cultures in 3 patients (although one of them was shown as gram-positive cocci by histopathological inspections of the surgical specimens). In the remaining 22 patients, the pathogens were Staphylococcus in 12 (54.5%) (11 S. aureus (2 each had methicillin-susceptible and methicillin-resistant S. aureus, 7 pathogen species were not stated and 1 S. epidermidis), 8 (36.4%) Streptococcus (3 viridans, 2 mutans, 1 anginosous, 1 α-hemolyticus and 1 pneumonia), 1 (4.5%) cardiobacterium hominis and 1 (4.5%) non-typhoid salmonell) (χ2 = 21.6, p = 0.0001). The associated congenital anomalies in the congenital group patients included corrected transposition of the great arteries (1), patent ductus arteriosus + atrial septal defect + double orifice mitral valve (1), right aortic arch (1), atrial septal defect (1), atrial septal defect and VSD (1), subaortic valve membrane (1), cleft tricuspid valve (1), aneurysm of sinus Valsalva (1), patent ductus arteriosus (2) left superior vena cava (3), anomalous left hepatic vein (2) and congenital pericardial defect (1), giving a total of 16 (50%) congenital heart defects. In comparison, the associated congenital anomalies in the acquired group patients were comprised of bicuspid aortic valve (6), patent fossa ovalis (3), aneurysm of sinus Valsalva (1), transposition of the great arteries + pulmonary atresia (1), left ventricle-coronary sinus fistula (1), atrial septal defect, VSD and patent ductus arteriosus (1), giving a total of 13 (14.8%) cases as shown by echocardiography or magnetic resonance imaging (MRI). There was a significant difference in the frequencies of associated congenital heart defects between the two groups (χ2 = 6.4, p = 0.0120).

Diagnosis

In one patient with unexpected sudden death, an LV-RA shunt was found incidentally at autopsy and in another 4 patients an LV-RA shunt was diagnosed by surgical exploration. The remaining 116 patients had a total of 248 diagnostic investigations performed. In 1 patient, diagnostic information for an LV-RA shunt by 3D TEE was not reported. Of the remaining 247 diagnostic images, TTE was the most commonly used method accounting for 55.1% of all diagnostic investigations, but showing limited diagnostic accuracy for 66.9% of cases. The TTE modes used in the diagnosis were colour Doppler 48 (64.9%), 2-D echo 12 (16.2%), continuous wave Doppler 13 (17.6%) and pulsed Doppler 1 (1/4%), respectively. Parasternal short axis and apical 4-chamber views were the most common views and colour Doppler imaging the most common mode for the diagnostic accuracy of TTE, but they were also the most common window and mode for inclusive diagnosis of intracardiac shunting locations. The subcostal 4-chamber images may provide the clearest view [18]. Pulsed Doppler and continuous Doppler mappings of TTE were less sensitive than colour Doppler in defining the shunt location. The TEE was the second most common technique for the diagnosis of LV-RA shunt, with a higher diagnostic accuracy (χ2 = 15.2, p < 0.0001), lower missed diagnosis (χ2 = 3.9, p = 0.0490) and lower inclusive diagnosis rates (χ2 = 7.0, p = 0.0080) in comparison to TTE, but their misdiagnosis rates did not differ from each other (χ2 = 1.8, p = 0.1770). Alternative diagnostic techniques for confirming the LV-RA shunt were cardiac catheterisation, MRI, computed tomographic angiography, contrast echocardiography and radioisotope cardiac scan, etc. The 11 misdiagnosed patients were initially mistaken as tricuspid regurgitation [6, 22] and tricuspid regurgitation and pulmonary artery hypertension [25, 83, 84] in 3 (27.3%) patients each and rupture of Valsalva aneurysm into the right atrium [14], prosthetic mitral valve leak [103], mitral valve regurgitation with prosthetic mitral valve leak [92], atrial septal defect [47] and residual VSD [8] in 1 (9.1%) patient each. There were 45 TTE images leading to misdiagnosis, missed diagnosis, or inclusive diagnosis in 33 patients, whose correct diagnoses were established mostly by alternative diagnostic techniques, with TEE being the most frequent (Figure 2).
Figure 2

Alternative diagnostic techniques for the correct diagnosis of the left ventricular to right atrial shunt in the 33 patients with a misdiagnosis, missed diagnosis, or inclusive diagnosis by transthoracic echocardiography

Alternative diagnostic techniques for the correct diagnosis of the left ventricular to right atrial shunt in the 33 patients with a misdiagnosis, missed diagnosis, or inclusive diagnosis by transthoracic echocardiography Shunting measurements were primarily carried out by cardiac catheterisation for the total pulmonary blood flow to total systemic blood flow ratio (Qp/Qs), direct measurement during the operation, TTE and TEE for shunt size, and TTE for pressure gradient and flow velocity measurements. In 6 patients, the shunt size was measured with different techniques, with a larger result by cardiac catheterisation than by TTE in 2 patients [85, 96] and by MRI than by TTE in 1 patient [12]. Shunt dimensions were smaller by direct measurement during the operation than by TTE [54]. Equal results were obtained between cardiac catheterisation and TTE [8] and between TTE and TEE [110] in one patient, each. Additionally, identical results of Qp/Qs were obtained by non-invasive (MRI and TTE) and invasive measurements (cardiac catheterisation) in 2 patients [25, 26]. Quantitative analysis did not reveal any intergroup differences in VSD size, Qp/Qs, peak velocity, pressure gradient across the VSD and pulmonary artery pressure.

Management and prognosis

No significant differences were noted in the patients subjected to different treatment strategies of surgical, interventional, conservative, no treatment, or spontaneous closure between congenital and acquired groups (Table II). The patients were on a follow-up of 12.6 ±10.8 (range: 0.5–48; median: 11) months (n = 32). No difference was present in the follow-up duration between the congenital and acquired groups (15.0 ±14.3 months vs. 12.3 ±10.4 months, p = 0.6427). The overall morbidity and mortality were 7.3% (9/123) and 6.5% (8/123), respectively. Eight (9.1%) patients from the acquired group had postoperative complications, including 4 (50% of the complications and 4.5% of the group) atrioventricular block (3 following interventional therapy [8, 43, 46] and 1 following surgical repair [104]), 2 (25% of the complications and 2.3% of the group) residual shunts and 1 (12.5% of the complications and 1.1% of the group) renal failure; whereas there was only 1 (3.1%) postoperative complication: mild aortic and tricuspid valve insufficiency in the congenital group (χ2 = 1.2, p = 0.2730). Eight (9.1%) patients died in the acquired group, while no patient died in the congenital group (χ2 = 3.1, p = 0.0770). In the acquired group, all 8 patients who dies had undergone surgical treatment, whereas none of the patients with interventional, conservative, no treatment, or spontaneous closure died. A significant difference was discovered in the mortality rates between the surgical and non-surgical patients (χ2 = 4.6, p = 0.0320).
Table II

Management strategies for left ventricular to right atrial shunt

ManagementCongenital (n = 28)Acquired (n = 82)χ2 Value of p
Surgical:19 (67.9)54 (65.9)0.00.8460
 Patch repair6 (21.4)22 (26.8)0.50.4800
 Pledgeted suture2 (7.1)4 (4.9)0.20.6700
 Direct suture1 (3.6)13 (15.9)2.40.1240
 Intraoperative device2 (7.1)1 (1.2)2.70.1010
 Surgical technique not given8 (28.6)14 (17.1)1.70.1860
 Associated cardiac operation5 (17.9)28 (34.1)3.70.0540
Interventional1 (3.6)13 (15.9)3.20.0730
Conservative1 (3.6)1 (1.2)0.60.4330
No treatment7 (25)12 (14.6)1.60.2120
Spontaneous closure0 (0)2 (2.4)0.70.3950
Management strategies for left ventricular to right atrial shunt

Discussion

Congenital LV-RA shunt is rare, accounting for < 1% of all congenital heart defects [55]. The mechanisms of the congenital LV-RA shunt from an embryologic viewpoint have not been fully described. The acquired LV-RA shunts may be caused by weakened membranous septum due to a previous operation [53], vegetation invasions of the membranous septum in IE [49], perforation of the upper portion of the membranous septum caused by an infection from IE in spite of the lack of vegetation [71], extended decalcification of the annulus in the posteromedial commissure or its vicinity during valve replacements [36, 51], or a tear in the tricuspid annulus at the membranous septum resulting in membranous septal injury [36]. Echocardiography was a gold standard for the diagnosis of the intracardiac shunts. However, the high velocity LV-RA jet may be misdiagnosed as tricuspid regurgitation with pulmonary artery hypertension [54, 83]. By echocardiography, the associated cardiac anomalies can be easily disclosed, whereas the VSD is sometimes be overlooked due to the dominance of the defect caused by the prosthesis in the aortic position [3]. Moreover, LV-RA shunts may display in several distinct anatomies on echocardiography, such as elongated sail-like [28], flap-like [38], a fistula form [85], a cystic thin walled structure [26], or a windsock-type tunnel appearance [8, 94], which make diagnosis difficult. To further define shunt anatomy and to quantify the shunt ratio, cardiac catheterisation and MRI are often advocated [74]. Pulsed wave Doppler is useful in localising the site of the intracardiac shunt by detecting a high-pitched audio signal and a turbulent as well as aliased flow velocity spectral display. Continuous wave Doppler can detect and measure peak systolic velocities across the shunt. Large defects are easily visualised by two-dimensional echocardiography and colour flow imaging may be used to localise small defects [114]. A Qp/Qs ratio of < 1.5 was typically suggestive of a small restrictive defect. When Qp/Qs was < 1.5: 1, the cardiac chambers were usually not enlarged and the pulmonary vasculature was usually normal; whereas for large shunts with a Qp/Qs > 2.0: 1, volume overload of the left atrium and left ventricle may develop with increased right ventricular and pulmonary arterial pressures [115]. Some authors [17, 97] have complained about the insensitivity of the parasternal, apical, or subcostal views of TTE for identifying the origin of the shunt. Desai et al. [19] reported that the parasternal long axis, parasternal short axis and apical four-chamber views were inadequate to demonstrate the exact location of the shunt and only revelaed a flow signal toward the tricuspid valve, mimicking tricuspid regurgitation. Dzwonczyk et al. [20] illustrated that 4-chamber view imaging could not determine the origin of the shunt, but a parastomal short-axis view could do this. Vallakati et al. [99] obtained a clear visualisation of the shunt with all views of TTE. The subcostal views (4-chamber or short-axis views) allow a clear visualisation as there is no bone or lung tissue to obstruct the view of the heart. The subcostal 4-chamber images show the clearest view of this defect [18, 80]. Continuous wave and pulsed Doppler mappings of an LV-RA shunt are often misinterpreted as tricuspid regurgitation [3]. Differential diagnosis should also be made from a ruptured sinus of Valsalva or an endocardial cushion defect in parasternal short-axis and subcostal views [18]. With a high-velocity jet detected in the right atrium rather than in the right ventricle by colour Doppler, flow imaging can help the diagnosis of the LV-RA shunt [15]. The jet velocity of the LV-RA shunt can be different from that of the tricuspid regurgitation, with the shunt generating a significant higher jet velocity and probably a higher pressure gradient than tricuspid regurgitation on colour and continuous wave Doppler from the apical 4-chamber view [20]. Although, the shunt location could not be determined by cardiac catheterisation, the oxygen saturation gradient between the superior vena cava and the right atrium may confirm the existence of the shunt [47]. Visualisation by cardiac MRI of an intracardiac shunt with a high-velocity jet impinging on the anterior tricuspid leaflet during systole and bouncing back into the right atrium as tricuspid regurgitation can be helpful in the diagnosis of an LV-RA shunt [17]. When doubts arise concerning the pulmonary artery hypertension in association with an intracardiac shunt, cardiac catheterisation should be performed in order to rule out false pulmonary hypertension [25]. A to-and-fro flow by TEE could clearly demonstrate the shunt [47, 64]. Furthermore, TEE guidance can be very useful in precisely locating the shunt and accurately measuring the distance from the defect to the aortic valve, thereby avoiding aortic valve entrapment during interventional management [46]. An LV-RA shunt should be suspected when there is an unusually dilated right atrium [35, 38, 46, 72, 101], the presence of an aortic root abscess or vegetations on the interatrial septum in the right atrium [33], or unexplained congestive heart failure [24, 64, 93, 103]. The present study revealed a dominance of right heart dilation, tricuspid regurgitation and pulmonary artery hypertension in patients with an LV-RA shunt of either congenital or acquired origin. The prevalence of right heart dilation did not differ between the two groups. As the diagnostic accuracy of TTE for the LV-RA shunt was 66.9%, the remaining 33.1% of patients had to resort to other diagnostic methods, 51.5% of which were TEE. With limited information for comparisons of different ways to measure of the shunt size, TTE can detect shunt size more accurately in nearly half of the patients, as long as it locates the shunt position with proper views; while in the other half of the patients, the shunt size by TTE can be smaller than that detected by cardiac catheterisation by several millimetres. In this patient setting, the Qp/Qs was detected by catheterisation in 27 (77.1%) patients, by TTE in 6 (15.8%) patients and by sporadically used techniques in 5 (13.2%) patients, thereby representing convincing results. The statistical analysis for Qp/Qs did not reveal a significant intergroup difference. Paravalvular abscess and atrioventricular block can be complicated in the acquired rather than in the congenital patients, indicating that the complications may play a role, at least in part, in the formation of an LV-RA shunt. The LV-RA shunt may often lead to very early and progressive congestive heart failure, usually within 6 months if left untreated properly [67]. Haemodynamic deterioration, a new LV-RA shunt and valvular destruction with ring abscess might be noted [87], so sometimes a surgical correction is warranted in these patients. However, Toprak et al. [96] recommended that patients with no symptoms and no right ventricular volume or pressure overload due to a small LV-RA shunt were not indicated for surgery but close follow-up was recommended instead. In the surgical operations, a patch repair should be performed on the right atrial side in order to prevent atrioventricular block [59, 94]. In long-term follow-up (up to 19.7 years) 17% of the LV-RA shunts spontaneously closed, while 8.5% developed IE during follow-up [105]. The nature of spontaneous closure was proven, by surgical exploration, to be aneurysmal transformation of the tricuspid septal leaflet [58]. Patients with an acquired LV-RA shunt received interventional therapy with the use of the Amplatzer occluders to close the shunts, with satisfactory results. The mortality rates of surgically treated patients were much higher than for non-surgically treated patients, probably because the surgical patients had more severe illnesses, such as aortic wall abscess, for which they were indicated for a surgical operation.

Conclusions

Congenital LV-RA shunt is rare; however, acquired LV-RA shunt has been increasingly reported. The diagnosis of an LV-RA shunt is quite challenging, especially when there are coexisted abnormalities such as an additional intracardiac shunt, tricuspid regurgitation, pulmonary artery hypertension and infective endocarditis, which have to be carefully differentiated from the shunt by further precise investigational techniques. A better control of infective complications and careful manoeuvres during surgery may help to keep the LV-RA-sensitive septum intact.
  103 in total

1.  Syndrome of left ventricular-right atrial shunt; successful surgical repair of defect in five cases, with observation of bradycardia on closure.

Authors:  F GERBODE; H HULTGREN; D MELROSE; J OSBORN
Journal:  Ann Surg       Date:  1958-09       Impact factor: 12.969

2.  A hidden echocardiographic pitfall: the Gerbode defect.

Authors:  Daniela Colomba; Mauro Cardillo; Alessandro Raffa; Christiano Argano; Giuseppe Licata
Journal:  Intern Emerg Med       Date:  2013-10-20       Impact factor: 3.397

3.  Left ventricular-right atrial communication following tricuspid annuloplasty.

Authors:  Shigeaki Aoyagi; Koichi Arinaga; Takeshi Oda; Hidetsugu Hori
Journal:  Eur J Cardiothorac Surg       Date:  2008-06-25       Impact factor: 4.191

4.  An unusual variation of left ventricular-right atrial communication.

Authors:  H Komai; Y Naito; K Fujiwara; Y Takagaki; Y Nishimura; S Kawasaki
Journal:  Surg Today       Date:  1996       Impact factor: 2.549

5.  Gerbode ventricular septum defect covered by a ballooning membranous ventricular septum.

Authors:  Ulrike M Müller; Undine Pittl; Sergey Leontyev; Ingo Dähnert; Gerhard C Schuler
Journal:  Clin Res Cardiol       Date:  2012-12-01       Impact factor: 5.460

6.  Left ventricle-right atrium communication along with a membranous septum aneurysm.

Authors:  Oner Ozdogan; Cahide S Cinar
Journal:  J Cardiovasc Med (Hagerstown)       Date:  2012-09       Impact factor: 2.160

7.  Ruptured aneurysm sinus of Valsalva and Gerbode defect with severe tricuspid and aortic regurgitation. A case report and its surgical correction.

Authors:  R Coelho; H S Pannu; S G Thakurta; R S Singh; S G Rao; K M Cherian
Journal:  J Cardiovasc Surg (Torino)       Date:  1997-10       Impact factor: 1.888

8.  Gerbode defect with Staphylococcus lugdunensis native tricuspid valve infective endocarditis.

Authors:  Robert J Carpenter; Gregory D Price; Gilbert E Boswell; Keshav R Nayak; Alfredo R Ramirez
Journal:  J Card Surg       Date:  2012-02-13       Impact factor: 1.620

9.  Left ventricular to right atrial communication (Gerbode-type defect) after mitral valve replacement.

Authors:  Ali Reza Moaref; Amir Aslani; Mahmood Zamirian; Mohammed Bagher Sharifkazemi
Journal:  J Am Soc Echocardiogr       Date:  2007-10-10       Impact factor: 5.251

10.  Are all ventricular septal defects created equal?

Authors:  Daniela Lax; Rajan D Bhatt; Scott E Klewer; Vincent L Sorrell
Journal:  J Am Soc Echocardiogr       Date:  2010-01-25       Impact factor: 5.251

View more
  12 in total

1.  Gerbode Defect-A Rare Defect of Atrioventricular Septum and Tricuspid Valve.

Authors:  Abhay Tidake; Pranil Gangurde; Ajay Mahajan
Journal:  J Clin Diagn Res       Date:  2015-09-01

2.  Gerbode Ventricular Septal Defect -A Rare Cardiac Anomaly Associated with Genetic Variants in Indian Population- A Case Series.

Authors:  Yashvanthi Borkar; Krishnananda Nayak; Ranjan K Shetty; Gopalakrishna Bhat; Rajasekhar Moka
Journal:  J Clin Diagn Res       Date:  2017-03-01

Review 3.  Ruptured Sinus of Valsalva Aneurysm and Gerbode Defects: Patient and Procedural Selection: the Key to Optimising Outcomes.

Authors:  Colm R Breatnach; Kevin P Walsh
Journal:  Curr Cardiol Rep       Date:  2018-08-20       Impact factor: 2.931

4.  Transcatheter Closure of Postoperative Residual VSD and Acquired Left Ventricle-to-Right Atrium Shunt with Using Two Different Devices.

Authors:  Erman Cilsal; İbrahim Cansaran Tanıdır; Bekir Yukcu; Murat Sahin; Alper Guzeltas
Journal:  Acta Cardiol Sin       Date:  2022-03       Impact factor: 2.672

5.  Successful device closure in a congenital Gerbode defect.

Authors:  Zeki Y Gunaydin; Yusuf E Gürel; Osman Bektaş; Ahmet Kaya
Journal:  Postepy Kardiol Interwencyjnej       Date:  2015-06-22       Impact factor: 1.426

6.  Percutaneous closure of congenital Gerbode defect using Nit-Occlud® Lê VSD coil.

Authors:  Quang T Phan; Sang-Wook Kim; Hieu L Nguyen
Journal:  World J Cardiol       Date:  2017-07-26

7.  Left ventricle penetration-A rare complication of transseptal puncture and catheter ablation for supraventricular tachycardia.

Authors:  Nelson Chavarria; Seth Goldbarg
Journal:  HeartRhythm Case Rep       Date:  2015-04-21

8.  Transcatheter closure of left ventricle to right atrial communication using cera duct occluder.

Authors:  Gnanavelu Ganesan; G Justin Paul; Vaikom S Mahadevan
Journal:  Indian Heart J       Date:  2017-01-26

9.  Atrioventricular Shunt Post Acute Myocardial Infarction.

Authors:  Priscilla Peters; Lucy Safi; Marie Sadler; Maritza Cotto
Journal:  CASE (Phila)       Date:  2017-02-27

Review 10.  Gerbode defect: A comprehensive review of its history, anatomy, embryology, pathophysiology, diagnosis, and treatment.

Authors:  Erfanul Saker; Ghazal N Bahri; Michael J Montalbano; Jaspreet Johal; Rachel A Graham; Gabrielle G Tardieu; Marios Loukas; R Shane Tubbs
Journal:  J Saudi Heart Assoc       Date:  2017-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.