Literature DB >> 25487713

Ionophore-containing siloprene membranes: direct comparison between conventional ion-selective electrodes and silicon nanowire-based field-effect transistors.

Anping Cao1, Marleen Mescher, Duco Bosma, Johan H Klootwijk, Ernst J R Sudhölter, Louis C P M de Smet.   

Abstract

Siloprene-based, ion-selective membranes (ISMs) were drop-casted onto a field-effect transistor device that consisted of a single-chip array of top-down prepared silicon nanowires (SiNWs). Within one array, two sets of SiNWs were covered with ISMs, each containing two different ionophores, allowing the simultaneous sensing of K and Na ions using a flow cell. It is shown that both ions can be effectively detected in the same solution over a wide concentration range from 10(-4) to 10(-1) M without interference. The ISMs were also analyzed in a conventional ISE configuration, allowing a direct comparison. While the responses for K(+) were similar for both sensor configurations, remarkably, the Na(+) response of the ISM-covered SiNW device was found to be higher than the one of the ISE configuration. The addition of a Na(+) buffering hydrogel layer between the SiO2 of the SiNW and the ISM reduced the response, showing the importance of keeping the boundary potential at the SiO2/ISM interface constant. The responses of the siloprene-covered SiNW devices were found to be stable over a period of at least 6 weeks, showing their potential as a multichannel sensor device.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25487713     DOI: 10.1021/ac504500s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Highly sensitive FET sensors for cadmium detection in one drop of human serum with a hand-held device and investigation of the sensing mechanism.

Authors:  Shin-Li Wang; Ching-Yen Hsieh; Chang-Run Wu; Jung-Chih Chen; Yu-Lin Wang
Journal:  Biomicrofluidics       Date:  2021-04-12       Impact factor: 2.800

2.  High-field modulated ion-selective field-effect-transistor (FET) sensors with sensitivity higher than the ideal Nernst sensitivity.

Authors:  Yi-Ting Chen; Indu Sarangadharan; Revathi Sukesan; Ching-Yen Hseih; Geng-Yen Lee; Jen-Inn Chyi; Yu-Lin Wang
Journal:  Sci Rep       Date:  2018-05-29       Impact factor: 4.379

3.  Hydrosulfide-selective ChemFETs for aqueous H2S/HS- measurement.

Authors:  Tobias J Sherbow; Grace M Kuhl; Grace A Lindquist; Jordan D Levine; Michael D Pluth; Darren W Johnson; Sean A Fontenot
Journal:  Sens Biosensing Res       Date:  2020-12-29